background image

 

Troubleshooting

 

Your Omnitec Design machine is designed and engineered to provide years of trouble free service. Occasionally problems 
occur. Here are some helpful tips and solutions

 

 

The machine does not start

 

1.

 

Check that the unit is plugged in and there is 115VAC available (or 230VAC for the 230VAC unit). Select either LOW or 

HIGH speed to turn the machine on. If the red indicator light comes on, power is coming to the unit from the outlet.

 

2.

 

Call Omnitec technical support to troubleshoot further.

 

 

The machine just hums when turned on

 

1.

 

Unplug the unit. 

2.

 

Remove the HEPA filter and push the blower wheel by hand. If it does not move freely or if you hear a grinding/ 

scrapping noise as you spin it, then the blower wheel is touching the side of the blower housing. This may be due to an impact 
of some kind and the motor mounts have been bent. Remove the motor/blower assembly and replaced the bent motor 
mounts. 

3.

 

If the blower spins freely, check the capacitor. With the HEPA filter still removed from the machine, insure that the 

wiring connected to the capacitor is plugged in and not broken. Re-plug the unit into the power outlet keeping the switch in 
the OFF position. Then push the blower wheel and as it is spinning, turn the speed selector switch to HIGH.  If the machine 
keeps running, the capacitor needs to be replaced.

 

 

The machine will run for a few minutes then turn off

 

1.

 

The machine must have a HEPA filter installed to operate properly. If you are trying to run it without a filter in place, 

the motor will overheat within a few minutes and the thermal overload will engage and shut it down. Let the motor cool off 
for 30 minutes, install the filter and try running the machine again. 

2.

 

If the filter is in place and the machine still shuts off after a few minutes then the motor is faulty. Replace the motor. 

 

The machine vibrates excessively when running

 

1.

 

This is an indication that the motor bearings are worn out. If the machine continues running, at this point the vibration 

will cause the center hub of the blower wheel to separate from the wheel requiring replacement of both the motor and 
blower. Replace the motor. 

2.

 

If the machine does require electrical servicing of the motor or switches the following page contains a wiring diagram 

to aid in repair or troubleshooting. 

Содержание OmniAire 2000C Series

Страница 1: ...1 2000C 2000V Series HEPA Air Filtration Machine Operation and Maintenance Manual ...

Страница 2: ...SERVER CES INSTRUCTIONS Cet équipement doit être utilisé que par un personnel formé Ne pas utiliser avec des matières combustibles ou explosives Ne pas exposer à l eau ou à la pluie Connectez uniquement à une prise mise à la terre avec un dispositif GFCI Coupez l alimentation électrique pour le nettoyage et l entretien Ne pas utiliser si le cordon ou la fiche est endommagé Contactez un centre de s...

Страница 3: ...ent and hook a flexible duct to the outlet ring of the machine ducting the exhaust into the containment See Above OmniAire 2000 Specifications Airflow 900CFM Low 1900 CFM OA2000C 400 1900 CFM Variable Range OA2000V Power Requirements 115VAC 60 Hz 10 6 Amp or 230VAC 60Hz 6 0A Motor 1 25 HP with thermal overload 115VAC or 1 0 HP with thermal overload 230VAC Optional MERV 15 bag filter OdorGuard 600 ...

Страница 4: ...set the rocker switch HIGH VARIABLE speed to the HIGH position In this position the SPEED CONTROL is disabled To start the machine in VARIABLE SPEED set the rocker switch to the VARIABLE SPEED position and rotate the SPEED CONTROL knob clockwise to obtain the desired airflow As the filters fill with dust the efficiency of the filters is maintained but the airflow will decrease and the vacuum readi...

Страница 5: ...uides and re install the filter tabs and filter tab securing nuts The nuts should initially be tightened to where the stud is flush with the end of the nut This will compress the gasket on the filter approximately 1 2 of the thickness This allows for the filter to be reseated and tightened at a later time if necessary Bag Filter Replacement For the projects that do not require a HEPA filter the ec...

Страница 6: ...ected to the capacitor is plugged in and not broken Re plug the unit into the power outlet keeping the switch in the OFF position Then push the blower wheel and as it is spinning turn the speed selector switch to HIGH If the machine keeps running the capacitor needs to be replaced The machine will run for a few minutes then turn off 1 The machine must have a HEPA filter installed to operate proper...

Страница 7: ...FILTER 99 97 0 3μ pb frame OAH2418 Bag Filter Housing includes 1 Bag Filter HBF2000 Bag Filter MERV 15 OBF9 Vapor Trap V bank Filter OCVT18 OdorGuard 600 Carbon Filter OG2418D Intake Manifold Kit Manifold Clamp 3 Duct OAIM2000 12KIT ABS Plastic Intake Manifold 12 Dia OAIM2000 12 Quick Clamp 12 16 Dia QCW14 Flexible Duct 12 Dia x 25 L OAD12 Flexible Duct Wire Fiber Reinforced OAD12R Revision 2 0 Se...

Страница 8: ...review the Equipment application and federal state and local regulations to be sure that the Equipment installation and use will comply with them Omni CleanAir offers extended warranty through the Gold Care Membership Program for as long as membership status is maintained For more information please visit https www omnicleanair com resources gold care membership To Submit a Warranty Claim or Recei...

Страница 9: ...9 ...

Отзывы: