Data Precision
–
set the number of digits for the data reported.
Command
Name
R/W
Value
F
n
Decimal Places
Write
Set
n
to the number of decimal places to be
reported. For example, setting to F2 will
report 2 decimal places (ex. 10.35). F0 will
provide the integer value only. Valid values of
n
are 0-5.
Sampling Rate/Buffer Size
–
set these values to control the sample rate of the sensor. This setting
influences the output data and the rate at which the data is reported. The buffer size influences the report
rate and accuracy. A buffer size of 512 will have a report rate between 5-30Hz. The accuracy becomes
worse by a factor of two with a 512-buffer size versus 1024 (Figure 6).
Command
Name
R/W
Value
SI
1K samples/second
Write
SV
5K samples/second
Write
SX or S1
10K samples/second
Write
S2
20K samples/second
Write
SL
50K samples/second
Write
SC
100K samples/second
Write
S>
1024 buffer size
Write
1024 samples are collected before processing
S<
512 buffer size
Write
512 samples are collected before processing
Figure 6. Buffer Size versus Accuracy