Data Precision

 

 set the number of digits for the data reported.   

Command 

Name 

R/W 

Value 

F

n

 

Decimal Places 

Write 

Set 

n

 to the number of decimal places to be 

reported.  For example, setting to F2 will 
report 2 decimal places (ex. 10.35).  F0 will 
provide the integer value only.  Valid values of 

n

 are 0-5. 

 

Sampling  Rate/Buffer  Size

 

  set  these  values  to  control  the  sample  rate  of  the  sensor.    This  setting 

influences the output data and the rate at which the data is reported.  The buffer size influences the report 
rate and accuracy.  A buffer size of 512 will have a report rate between 5-30Hz.  The accuracy becomes 
worse by a factor of two with a 512-buffer size versus 1024 (Figure 6). 

Command 

Name 

R/W 

Value 

SI 

1K samples/second 

Write 

 

SV 

5K samples/second 

Write 

 

SX or S1 

10K samples/second 

Write 

 

S2 

20K samples/second 

Write 

 

SL 

50K samples/second 

Write 

 

SC 

100K samples/second 

Write 

 

S> 

1024 buffer size 

Write 

1024 samples are collected before processing 

S< 

512 buffer size 

Write 

512 samples are collected before processing 

 

 

Figure 6. Buffer Size versus Accuracy

 

 

 

0.0

0.2

0.4

0.6

0.8

1.0

1.2

1.4

 1,000

 5,000

 10,000

 20,000

 50,000

 100,000

Acc

u

ra

cy

 (m/

s)

Sampling Rate

512 Buffer

1024 Buffer

Содержание OPS242

Страница 1: ...ions The OPS242 provides a complete radar module on a single board The coverage area or field of view FOV for the OPS242 is 76 in the azimuth horizontal and elevation vertical Install the OPS242 facin...

Страница 2: ...configuration window such as in Figure 2 or Figure 3 will appear TeraTerm can detect the active COM port greyed out to right of Serial button if TCP IP is selected Select the Serial button and press...

Страница 3: ...OPS UM 001 C User Manual OmniPreSense Corporation 3 Figure 4 Streaming Data with Tera Term Figure 5 Streaming Data with PuTTY...

Страница 4: ...Output Or Off Speed Report OS On Time Report Ot Off Module Power PA Active Operating Range The maximum speed reported is determined by the Sampling Frequency For slow moving objects a sample rate of...

Страница 5: ...ber returns sensor model number consisting of OmniPreSense ACPI vendor ID and part number Command Name R W Value P Sensor Part Number Read Product OMPS242A Firmware Version returns current firmware ve...

Страница 6: ...rted The buffer size influences the report rate and accuracy A buffer size of 512 will have a report rate between 5 30Hz The accuracy becomes worse by a factor of two with a 512 buffer size versus 102...

Страница 7: ...orts outbound direction R Clear Direction Control Write Reports both directions Frequency Control use this setting to set the desired transmit frequency Set n to a positive or negative number between...

Страница 8: ...te Turn the LEDs on OL or off Ol Turning off the LED s can save approximately 10mA of current consumption On Number Reports Write Define how many reports to provide n is a number between 1 and 9 The n...

Страница 9: ...powered down for further power savings PP Single Shot Mode Write Use this mode to capture and process a single buffer of data The module will stay in PP mode until either a PA or PI command is given...

Страница 10: ...umbers are least sensitive Command Name R W Value QI Squelch Control 100 Write Highest sensitivity setting QV Squelch Control 500 Write QX Squelch Control 1 000 Write QL Squelch Control 5 000 Write QC...

Страница 11: ...cian for help FCC 15C Statement This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause interference and 2 this device must...

Страница 12: ...not approved any changes or modifications to this device by the user Any changes or modifications could void the user s authority to operate the equipment The final product containing the modular tran...

Страница 13: ...M 001 C User Manual OmniPreSense Corporation 13 Revision History Version Date Description A July 9 2018 Initial release B August 10 2018 FCC language added C August 27 2018 Correction to frequency cha...

Отзывы: