FCC 15B Statement

 

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant 
to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful 
interference in a residential installation. This equipment generates, uses and can radiate radio frequency 
energy and, if not installed and used in accordance with the instructions, may cause harmful interference 
to radio communications. However, there is no guarantee that interference will not occur in a particular 
installation. If this equipment does cause harmful interference to radio or television reception, which can 
be  determined  by  turning  the  equipment  off  and  on,  the  user  is  encouraged  to  try  to  correct  the 
interference by one or more of the following measures:  

Reorient or relocate the receiving antenna.  

Increase the separation between the equipment and receiver.  

Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.  

Consult the dealer or an experienced radio/TV technician for help. 

 

FCC 15C Statement

 

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 
(1) this device may not cause interference, and (2) this device must  accept any interference, including 
interference that may cause undesired operation of the device. 

 

FCC RF Exposure Statement 

This transmitter must be installed to provide a separation distance of at least 20cm from all persons and 
must not be co-located or operating in conjunction with any other antenna or transmitter. End-users must 
be provided with transmitter operation conditions for satisfying RF exposure compliance. 

  

IC Statement (English and French):

 

This  device  complies  with  ISED  Canada  license-exempt  RSS  standard(s).  Operation  is  subject  to  the 
following two conditions: (1) this device may not cause interference, and (2) this device must accept any 
interference, including interference that may cause undesired operation of the device. 

  

Le  présent  appareil  est  conforme  aux  CNR  d'ISED  Canada  applicables  aux  appareils  radio  exempts  de 
licence. L'exploitation est autorisée aux deux conditions suivantes: (1) l'appareil ne doit pas produire de 
brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radio électrique subi, même si le 
brouillage est susceptible d'en comprom-ettre le fonctionnement. 

Содержание OPS242

Страница 1: ...ions The OPS242 provides a complete radar module on a single board The coverage area or field of view FOV for the OPS242 is 76 in the azimuth horizontal and elevation vertical Install the OPS242 facin...

Страница 2: ...configuration window such as in Figure 2 or Figure 3 will appear TeraTerm can detect the active COM port greyed out to right of Serial button if TCP IP is selected Select the Serial button and press...

Страница 3: ...OPS UM 001 C User Manual OmniPreSense Corporation 3 Figure 4 Streaming Data with Tera Term Figure 5 Streaming Data with PuTTY...

Страница 4: ...Output Or Off Speed Report OS On Time Report Ot Off Module Power PA Active Operating Range The maximum speed reported is determined by the Sampling Frequency For slow moving objects a sample rate of...

Страница 5: ...ber returns sensor model number consisting of OmniPreSense ACPI vendor ID and part number Command Name R W Value P Sensor Part Number Read Product OMPS242A Firmware Version returns current firmware ve...

Страница 6: ...rted The buffer size influences the report rate and accuracy A buffer size of 512 will have a report rate between 5 30Hz The accuracy becomes worse by a factor of two with a 512 buffer size versus 102...

Страница 7: ...orts outbound direction R Clear Direction Control Write Reports both directions Frequency Control use this setting to set the desired transmit frequency Set n to a positive or negative number between...

Страница 8: ...te Turn the LEDs on OL or off Ol Turning off the LED s can save approximately 10mA of current consumption On Number Reports Write Define how many reports to provide n is a number between 1 and 9 The n...

Страница 9: ...powered down for further power savings PP Single Shot Mode Write Use this mode to capture and process a single buffer of data The module will stay in PP mode until either a PA or PI command is given...

Страница 10: ...umbers are least sensitive Command Name R W Value QI Squelch Control 100 Write Highest sensitivity setting QV Squelch Control 500 Write QX Squelch Control 1 000 Write QL Squelch Control 5 000 Write QC...

Страница 11: ...cian for help FCC 15C Statement This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause interference and 2 this device must...

Страница 12: ...not approved any changes or modifications to this device by the user Any changes or modifications could void the user s authority to operate the equipment The final product containing the modular tran...

Страница 13: ...M 001 C User Manual OmniPreSense Corporation 13 Revision History Version Date Description A July 9 2018 Initial release B August 10 2018 FCC language added C August 27 2018 Correction to frequency cha...

Отзывы: