8. MOVE the 

selector switch 

to the center 

OFF position.

9.  SWITCH

 off 

the wall outlet 

socket.

10. REMOVE 

the wall power 

supply from the 

wall socket.

11. REMOVE the wall power supply connector

 

from the Omnilux clear-U.

12. CLEAN

 the transparent lens of the Omnilux 

 

clear-U with a damp (not wet) cloth or an 

 

isopropyl alcohol wipe.

13.  PLACE

 the Omnilux clear-U and the wall

 

power supply in a safe storage area.

PAGE 13

How to use the Omnilux clear-U

Before a treatment session 

ALWAYS 

wash the skin 

with a suitable skin cleanser to remove all product 

residues, pollutants, and any traces of make-up. 

This will make sure that all the light from the 

Omnilux clear-U reaches the skin.

1.   ALWAYS

 switch the wall outlet socket off. If 

 

you do not switch the outlet off there is a risk 

 

that you may touch a live pin when plugging 

 

the Wall Power Supply into the outlet.

2.   PLUG

 the power supply mains cable into the 

 

wall outlet socket.

3.  PLUG

 the power supply connector into the 

 

Omnilux clear-U.

4.   SWITCH

 the wall outlet socket on.

5.   OPERATE

 the selector switch on the front of 

 

the Omnilux clear-U to turn on the correct

 

color LEDs for the treatment session. 

 

(See ‘Treatment Recommendations’).

6.   PLACE

 the transparent lens of the Omnilux 

 

clear-U in contact with the treatment area.

7.   REMOVE the Omnilux clear-U from the  

 

affected area after the correct treatment time.  

 

(See ‘Treatment Recommendations’).

Содержание Clear-U

Страница 1: ...USER GUIDE For beautiful clear skin switch on the light...

Страница 2: ...magnetic optical chemical manual or otherwise without the prior written consent of Photo Therapeutics Inc Contents Introduction 1 The Omnilux clear U 3 Omnilux clear U Lifetime 6 Indications for Use...

Страница 3: ...frequently asked questions about light therapy and acne However the entire user guide must be read before operating the unit What is acne Acne is NOT caused by bad diet or greasy foods In fact acne d...

Страница 4: ...of acne pimples in a clinical study an average of 7 out of every 10 inflamed red pimples or spots had cleared following a course of Omnilux clear U Is Omnilux clear U safe and painless Yes subjects o...

Страница 5: ...separate Wall Power Supply with Cord The Omnilux clear U treatment unit contains an array of Light Emitting Diodes LEDs a ventilation fan a three position switch and a connection socket 3 way switch L...

Страница 6: ...wavelength The switch on the front of the Omnilux clear U allows you to choose between the RED light output the BLUE light output or the OFF position Omnilux clear U treatment unit Switch Positions M...

Страница 7: ...all coaxial connector which plugs into the socket on the rear of the Omnilux clear U Omnilux Wall Power Supply with Cord The Omnilux clear U has been tested to International standards to ensure that i...

Страница 8: ...to be run continuously for one or two years before the eye might begin to notice The Omnilux clear U has been designed with this effect in mind The brightness and lifetime of the LEDs used in the Omn...

Страница 9: ...his type of treatment please consult your doctor for a more appropriate treatment 4 Comedonal acne is characterized by whiteheads and blackheads small raised white or black bumps under the skin If you...

Страница 10: ...The safety of the treatment for children less than 12 years of age has NOT been tested in trials To reduce the risk of serious injury or fatal electrical shock NEVER use the Omnilux clear U or the Wa...

Страница 11: ...ock the air vents ALWAYS keep the Omnilux clear U its Wall Power Supply and cord away from heated surfaces High temperatures may damage the plastic cases or the internal parts ALWAYS unplug the Wall P...

Страница 12: ...lear U 4 SWITCH the wall outlet socket on 5 OPERATE the selector switch on the front of the Omnilux clear U to turn on the red LEDs place the transparent lens of the Omnilux clear U in contact with or...

Страница 13: ...atment has stopped You may experience erythema mild skin redness If it lasts longer than 24 hours you should stop using the Omnilux clear U and seek advice from a healthcare professional The Omnilux c...

Страница 14: ...adverse reaction within 24 hours start treatment regime 20 minutes BLUE light 3 Week 1 first day Day 1 20 minutes BLUE light 4 Two days later Day 3 20 minutes RED light 5 Week 2 first day Day 8 20 min...

Страница 15: ...up This will make sure that all the light from the Omnilux clear U reaches the skin 1 ALWAYS switch the wall outlet socket off If you do not switch the outlet off there is a risk that you may touch a...

Страница 16: ...efore the lamp is cleaned Outside the United States The Wall Power Supply which comes with your PAGE 14 Omnilux clear U is designed to operate with an electrical input between 90 250 Volts at 50 60 Cy...

Страница 17: ...uring treatment fan running Overheating Ensure ventilation slots are not blocked Allow a few minutes for the Omnilux clear U to cool and try again If the problem persists return your device to Photo T...

Страница 18: ...urrent and voltage Any other conditions beyond our control Photo Therapeutics Inc shall not be responsible for any incidental special or consequential damages resulting from the use of this product Al...

Страница 19: ...r U has been classified as a CLASS 1 device in accordance with the requirements of the international standard IEC 60825 1 2001 Safety of LED Products This standard also recommends Maximum Permissible...

Страница 20: ...United Kingdom Sales 44 0 1827 252 830 Support 44 0 161 925 5610 Facsimile 44 0 1827 287 391 Photo Therapeutics Inc 2720 Loker Ave West Suite C Carlsbad CA 92010 USA Tel 760 607 0488 Toll Free 800 74...