art. 0872 
FB 04-182 Rev. 5 
Date: 21.01.2019 

 

 
 
 
 
 
 
 

Manual 

 

 

 

 

Xantos-Nail 

Содержание Xantos-Nail 0872

Страница 1: ...art 0872 FB 04 182 Rev 5 Date 21 01 2019 Manual Xantos Nail ...

Страница 2: ...g to Know the Unit 8 Before First Use 9 Area of Application 9 Installation Site 9 Application 10 Starting up and Operating the Unit 10 Clamping the Bur Tool 10 Setting up the Speed 10 Maintenance Care 11 Handling Instructions 12 Troubleshooting 13 Technical Data 15 ...

Страница 3: ... not blocked and the extracted air can escape well Only switch on the unit if the handpiece rests secured in the handpiece holder or if you hold it safely in your hand To avoid the risk of electrocution only connect the device to the mains power supply If you pull the power plug it will stop the connection to the mains power supply Set up the unit so that the power plug is always accessible The po...

Страница 4: ...illing unit with suction or spray technique Wear a nose and mouth protection Always follow the safety instructions provided by the manufacturer of the materials being formed and used For safety reasons wear goggles during the treatment Ensure that the patient s foot and the handpiece are held firmly in place during the operation To prevent injury work with extreme caution on the foot of the patien...

Страница 5: ...y with the appliance Before using the equipment assure that the tool can be pushed far enough into the chuck Test this with a dipstick and clean the handpiece if necessary the inserted tool sits properly in the chuck and will not cant jam while clamping it the tool is approved for using it at the max speed see manufacturer s instructions or only use the speed required by the instrument the tool is...

Страница 6: ... yourself This is only to be accomplished by an authorized specialist The mains cable may also only be changed by the manufacturer or an authorized specialist Never remove the housing especially not while the equipment is plugged into the socket since some components are under electric voltage Any unauthorized or improper handling e g trying to repair the unit of the equipment will immediately nul...

Страница 7: ...ting tool e g bur capper etc first Then handle the cleaning of the tool according to the instructions of its manufacturer Remove tissue remains by wiping off the unit with a mildly moistened paper cloth Afterwards clean all surfaces with disinfection cloth e g Mikrozid AF Tücher of Schülke and Mayr ...

Страница 8: ...8 Getting to Know the Unit 1 speed display 2 LED 3 increase speed 4 change direction of rotation 5 decrease speed 6 ON OFF button 8 ...

Страница 9: ...ry dental technique dental laboratory Milling trimming and polishing work at plaster casts and models Do not use this unit for dentist purposes i e working directly on the patient industry grinding milling and polishing works Installation Site The installation of the workroom must correspond to any regulations according to your country laws Set up the control unit so that the ventilation slits are...

Страница 10: ...e hand Turn the ring spot B clockwise with your free hand until it snaps Now the chuck is opened Insert the bur until the end of the chuck Screw the ring B counter clockwise until it snaps Check if the bur sticks well It sticks well when you cannot pull it out Please do not turn on the unit while the chuck is opened This can damage the motor and the electronic devices For security reasons only cha...

Страница 11: ...eekly cleaning every 20 working hours Screw off the top pg 10 and brush off the loose parts with the added brush Hold the handpiece that way that the top points downward the table to avoid that more dirt can enter the inside of the handpiece ...

Страница 12: ...e when you not working with the handpiece always remove the bur tool from it Always make sure that you do not let the handpiece fall down or exposes it to any shocks The ball bearings and the motor could be damaged by this Only work with tools which are flawless Do not work with tools which are bent or out of balance whose shaft is worn out or are rusty Working with faulty tools will cause a stron...

Страница 13: ...ck the position of the spring on the carbon The spring should be in the middle of the carbon The carbon is a wearing part and has to be replaced after it is worn out A pair of carbons was added to your delivery Then also check the second carbon If the handpiece becomes hot In case the handpiece should become hot or the noise level extraordinary loud apparently the ball bearings of the front part o...

Страница 14: ...14 Troubleshooting Assembly Drawing More manuals for repair workshops you will find at http hadewe online de guides index htm Attend to fitting position ...

Страница 15: ...e in household refuse Respect your local disposal regulations Declaration of Conformity We declare under our sole responsibility that the products 0872 and to which this declaration relates are conform to the following standards or normative documents 2014 30 EU directive EMC 2014 35 EU low voltage directive hadewe GmbH Grambartstraße 10 30165 Hannover Germany Safety Check A safety check must be d...