41
7.2
LCD Display
The display content consists of 2 lines. The bottom line (Line 2) always displays the output
power (Pac = xxxx W). The top line (Line 1) shows current state information by default, and by
pressing function key it will display different operating information as the following flow chart
and table.
execution sequence
name
LCD example
1
Day total energy/kWh
E-Today = xx.x kWh
2
Total energy/kWh
E-Total = xxxxx kWh
3
PV Voltage/V
Vpv = xxx.x V
4
PV Current/A
Ipv = xx.x A
5
Grid voltage/V
Vac = xxx.x V
6
Grid current/A
Iac = xx.x A
7
Grid frequency/Hz
Frequency = xx.x Hz
8
Models
Omniksol-3k-TL3-S
9
Standard
Italy
10
Version
Version
11
Temperature
Temperature
12
Language
Language
:
English
13
S/N and IP address
SN/IP
14
Time setting
Date: 20xx-xx-xx
Time : xx:xx:xx
15
Grid setting
Set V/F Value
16
Protect setting
Protect
:
xx
17
Coefficient setting
Coefficient
18
Self Test(for Italy)
Self Test
19
P(f)and Q(v)
P(f)&Q(v)
20
Error Record
Error Record
*
Item 9 and 15 - 20 needs passwords. Contact your dealer or Omnik if you need to set them.