background image

2. Peel back the bag from the cut end and use it as a holder to

insert the RO Membrane, O-Rings first, into the Membrane
Housing (see Figure 9).

3. Push the RO membrane into the housing until it seats. The end of

the membrane should be about 3/8” into the housing.

4. Check the O-Ring on the membrane housing shoulder to make

sure it is seated in place.

5. Screw the membrane housing cap back onto the membrane

housing. Firmly hand tighten the cap on the housing, but do not
overtighten it and do not use a wrench.

Flushing the System

1. Open the cold water supply valve and the Cold Water Saddle

Valve, allowing the water to enter your system.

2. Open the RO faucet and let it run for one hour.

3. Close the RO faucet and open the storage tank valve. Check the

system for leaks.

4. Put the RO unit under the sink.

5. Let the RO unit charge for at least 6 hours. Periodically check for

leaks. Then open the RO faucet and let the water run until the air
and carbon fines are out of the system. Close the faucet.

6. Let the system charge for approximately another 6 hours.

7. Open the RO faucet and let the water run until the water comes

out at a slow drip or stops. Close the faucet and allow the system
to fill.

Your system is now ready for use.

TDS MONITOR OPERATION

Once the drinking water system installation is complete, run water
from the RO faucet and watch the LED in the base of the faucet.
• A green light will appear if the product water TDS is below the

set point. No action is required.

• An amber light will appear if the product water TDS is above the

set point. Proceed with Steps 1 and 2 below.

1. Run a few cups of water through the faucet and see if the LED

changes to green.

2. If the color of the LED does not change, run the water until the

storage tank is empty.
Allow the tank to refill and recheck it. If the LED is still amber, the
drinking water system may require service.

• If the LED is blank, replace the battery.

PRE-FILTER CARTRIDGE CHANGE
(TO1 AND  CB1)

NOTICE:

Do not disconnect any tubing for this operation!

1. Turn off the water supply either at the Cold Water Saddle Valve

or the cold water supply valve.

2. Close the valve on the storage tank.

3. Open the RO faucet until the water stops running; close the

faucet.

4. Pull the RO unit out from under the sink (don’t bring the storage

tank out) and put it in a shallow pan on the floor in front of the
sink.

NOTICE:

Do not disconnect any tubing!

5. Using the plastic tank wrench supplied, remove Pre-Filter Tanks

TO1 and CB1. Be careful – the tanks will be full of water.

6. Remove the used cartridges and dispose of them.

7. Check the tank O-Rings to be sure that they are seated properly.

Apply vegetable oil to the O-Rings.

8. Rinse the tanks with clear water (no soap) and wipe them out

with a clean rag or paper towel.

9. Put the replacement filter cartridges into the tanks and reinstall

the tanks.

NOTICE: 

The 

carbon

filter cartridge (dark grey) goes onto the

tank head marked TO1 (toward the prefilter inlet). The 

CB

filter

cartridge (white) goes onto the tank head marked CB1 (toward
the unit outlet).

10. Screw the filter tanks onto the tank heads firmly hand tight.

NOTICE: Do not

use the wrench to tighten the filter tanks – you

could crack the tanks or the tank heads. Tighten them hand-
tight only.

POST FILTER REMOVAL AND
INSTALLATION

1. Note that the large end of the R200 Post Filter is on the same

end of the unit as the membrane housing cap. The new Post
Filter must be installed with the same orientation.

2. Disconnect the tubing from the old Post Filter (see Figures 5 and

6) and pull it out of the brackets holding it to the RO membrane
housing.

3. Insert the yellow tubing into the input end of the new Post Filter.

Push it in firmly until it stops (about 5/8” of tubing should go
into the connector).

NOTICE:

Before reconnecting the filter note the flow direction

arrow on the filter. Be sure it is installed correctly.

4. Insert the blue tubing into the output end of the new Post Filter.

Push it in firmly until it stops (about 5/8” of tubing should go
into the connector).

5. Snap the new Post Filter into its brackets on the RO membrane

housing (inlet end toward the Membrane Housing Cap).

6. Open the RO faucet, the valve on the storage tank, and the

water supply valve. Flush the system until the water stops run-
ning or slows down to a slow drip. This will flush the ‘carbon
fines’ (very small particles of carbon that are present in a new
cartridge) out of the system.

7. Turn off the faucet and check for leaks. Carefully tighten any-

thing that is leaking. Do not overtighten fittings.

8. Put the RO unit back under the sink and let it charge for at least

6 hours. After 6 hours, check for leaks. Open the RO faucet and
let the water run until the air and carbon fines are out of the
system. Close the faucet.

9. Let the system charge for approximately another 6 hours.

Your system is now ready for use.

4

3637 0100

Do not touch 

the membrane

with your bare hands!

Figure 9: Peel the bag back from the membrane before
inserting in housing

Содержание RO2000 Series

Страница 1: ...ssary drill or punch a 1 1 8 hole in the sink top 3 Remove the nut and spacer from the RO faucet and feed the two lengths of black tubing attached to the faucet stem down through the hole in the sink top until the faucet is seated on the sink top The vertical ridge on the faucet handle should be facing toward the user 4 Reach below the sink top and slide the channel washer up the faucet stem Insta...

Страница 2: ...ough the wall of the supply line Do not force it and do not overtighten REVERSE OSMOSIS RO UNIT ASSEMBLY AND INSTALLATION 1 Place the storage tank in a convenient location under the sink Make sure that the tank valve is OPEN See Figure 4 2 Place the RO unit in a shallow pan on the floor in front of the sink 3 Connect the free end of the 1 4 black tube out of the faucet to the compression fitting c...

Страница 3: ...itor Be sure that the connection ports on the electronics enclosure face down 2 Run the grey telephone style cable with the yellow plug from the RO faucet to the right hand yellow port on the TDS Monitor 3 Run the grey telephone style cable from the white flow switch to the left hand port on the TDS Monitor 4 Remove the lid from the monitor and install a 9 volt battery pur chase separately Use a p...

Страница 4: ...any tubing 5 Using the plastic tank wrench supplied remove Pre Filter Tanks TO1 and CB1 Be careful the tanks will be full of water 6 Remove the used cartridges and dispose of them 7 Check the tank O Rings to be sure that they are seated properly Apply vegetable oil to the O Rings 8 Rinse the tanks with clear water no soap and wipe them out with a clean rag or paper towel 9 Put the replacement filt...

Страница 5: ...e the O Ring with vegetable oil 2 Unscrew the compression nut holding the black tube onto the membrane housing 3 Gently remove the tube from the membrane housing port keep the nut on the tube 4 Remove and discard the flow restrictor from the end of the black tube see Figure 10 5 Install the new flow restrictor in the end of the tubing as shown in Figure 10 Make sure that the collar on the flow res...

Страница 6: ...I NSF Standard 58 for the reduction of Fluoride Cysts Lead TDS Nitrate and Nitrite For further operating installation or maintenance assistance Call Omnifilter Customer Service at 800 937 6664 The Chlorine claim was tested off of the R200 post filter NOTICES Daily production rate is 13 gpd The reverse osmosis system contains a replaceable treatment component critical for the effective reduction of...

Страница 7: ...orter à la Figure 1 1 Fermer le robinet d arrivée d eau froide 2 Au besoin percer ou perforer un trou de 1 1 8 pouce dans le dessus de l évier 3 Déposer l écrou et l entretoise du robinet d eau traitée de l évier et faire passer les deux tubes noirs branchés sur la tige du robinet dans le trou de l évier jusqu à ce que le robinet repose sur l évier La saillie verticale de la poignée du robinet doi...

Страница 8: ...asser à l opération 5 Dans le cas du modèle RO2000 TDS passer à l opération 4 qui suit 4 Visser le contacteur débitmétrique blanc sur l extrémité du robinet se reporter à la Figure 6 A Piercing Needle Cold Water Pipe B C 3631 0100 Secure the Saddle Valve by tightening the nuts and bolts Turn handle clockwise to pierce the supply line with the piercing needle Figure 3 Installation du robinet à étri...

Страница 9: ...dans un endroit pratique sur le mur à l aide des attaches autoadhésives du module de contrôle S assurer que les orifices de branchement du boîtier électron ique sont orientés vers le bas 2 Amener le câble gris de type téléphone muni d une prise jaune branché sur le robinet d eau traitée de l évier jusqu à l orifice jaune qui se trouve à droite du module de contrôle des matières totales dissoutes 3...

Страница 10: ... d eau traitée et les mettre dans un bac creux sur le plancher à l avant de l évier NOTA Ne débrancher aucun tube 5 À l aide de la clé en plastique fournie déposer les cuves des cartouches préfiltrantes TO1 et CB1 Prudence les cuves sont pleines d eau 6 Sortir les cartouches filtrantes puis les jeter 7 Vérifier les joints toriques des cuves et s assurer qu ils reposent adéquate ment Appliquer de l...

Страница 11: ...ice de la cuve de la membrane laisser l écrou sur le tube 4 Déposer et jeter le limiteur de débit de l extrémité du tube noir se reporter à la Figure 10 5 Poser le limiteur de débit neuf dans l extrémité du tube comme il est illustré à la Figure 10 S assurer que le rebord du limiteur de débit repose contre l extrémité du tube NOTA Ne pas couper le limiteur de débit 6 Introduire le tube noir d envi...

Страница 12: ...SF en ce qui concerne la réduction de fluore de kystes de plomb de matières totales dissoutes de nitrate et de nitrite Pour tout autre renseignement concernant le fonctionnement l installation ou l entretien Appeler le service à la clientèle Omnifilter en composant le 800 937 6664 La réduction de chlore a été testée avec une cartouche postfiltrante R200 NOTA La production journalière d eau traitée...

Страница 13: ...del fregadero 3 Saque la tuerca y el espaciador del grifo de OI y haga pasar dos largos del tubo negro conectado al vástago del grifo hacia abajo por el orificio en la parte superior del fregadero hasta que el grifo quede asentado sobre la parte superior del fregadero La protuberancia vertical del mango del grifo debe quedar mirando hacia el usuario 4 Debajo de la parte superior del fregadero haga...

Страница 14: ...lo RO2000 vaya al paso 5 Para el Modelo RO2000 TDS vaya al paso 4 a continuación 4 Enrosque el conmutador de flujo blanco al extremo del grifo ver Figura 6 14 A Piercing Needle Cold Water Pipe B C 3631 0100 Secure the Saddle Valve by tightening the nuts and bolts Turn handle clockwise to pierce the supply line with the piercing needle Figura 3 Instalación de la Llave de Silla para Agua Fría Shut O...

Страница 15: ... monitor Asegúrese de que las aberturas de conexión en el recinto electrónico estén mirando hacia abajo 2 Haga correr el cable gris tipo telefónico con el enchufe amarillo desde el grifo de OI a la abertura derecha amarilla en el Monitor TDS 3 Haga correr el cable gris tipo telefónico desde el conmutador blanco de flujo a la abertura izquierda en el Monitor TDS 4 Saque la tapa del monitor e instal...

Страница 16: ...uercas para tanques de plástico suministrada saque los Tanques de Prefiltración TO1 y CB1 Tenga cuidado ya que los tan ques estarán llenos de agua 6 Saque los cartuchos usados y deséchelos 7 Inspeccione los aros tóricos del tanque para asegurarse de que estén debidamente acomodados Aplique aceite vegetal en los aros tóricos 8 Enjuague los tanques con agua limpia sin jabón y séquelos con un paño li...

Страница 17: ...embrana 3 Delicadamente retire el tubo de la abertura de la envoltura de la membrana manteniendo la tuerca en el tubo 4 Saque y deseche el restrictor de flujo del extremo del tubo negro ver Figura 10 5 Instale el nuevo restrictor de flujo en el extremo de la tubería según se ilustra en la Figura 9 Asegúrese de que el collarín en el restrictor de flujo quede acomodado contra el extremo del tubo AVI...

Страница 18: ...uro esporas plomo TDS Nitrato y Nitrito Para mayor asistencia sobre el funcionamiento instalación o mantenimiento Llame al departamento de servicio al cliente de Omnifilter al 800 937 6664 La reivindicación sobre el cloro no fue incluida en la prueba del postfiltro R200 AVISOS La tasa de producción diaria es de 13 gpd El sistema de osmosis inversa contiene un componente de tratamien to reemplazabl...

Страница 19: ...19 ...

Страница 20: ...20 ...

Отзывы: