1 - 2 YEAR  RO MEMBRANE  CHANGE/
CARTRIDGE CHANGE/SYSTEM DISINFECTION

NOTICE: 

The quality of the supply water feeding the RO system will

directly affect RO membrane life and Pre-filter Cartridge life.

A. Remove Pre-filter Cartridges and RO Membrane.

1. Follow Steps 1 through 6, under “Pre-filter Cartridge

Change”, Page 4.

2. Unscrew the RO membrane housing cap and pull the RO

membrane out with pliers. Be sure you don’t touch the mem-
brane with your bare hands. Be careful – the membrane
housing is full of water. Leave the post filter in place for now.

3. Clean the Pre-filter tanks and O-Rings in warm (no soap)

water. Rinse them thoroughly.

4. Re-lubricate the O-Rings with vegetable oil and seat them in

the tanks.

B. Fill RO Membrane Housing and Pre-filter Tanks.

1. Run water into pre-filter Tank 1 until it is half-full.  Add 1/2

teaspoon of standard chlorine bleach (unscented). Depress
blue air-bleed buttons on top of tanks to allow air to escape
and tanks to fill.

2. Re-install (without cartridges) both pre-filter tanks. Firmly

hand-tighten them.

3. Screw the RO membrane housing cap back on (without

installing the membrane) to the RO membrane housing.

Make sure you still have the RO membrane outside of the
housing before going on to the next step.

C. Soak and Flush the System.

NOTICE:

The RO membrane is chlorine sensitive and will deteri-

orate if exposed to chlorine. Make sure that all chlorine has been
flushed out of the membrane housing and pre-filter tanks before
reinstalling the RO membrane. 
1. Turn the cold water supply on.
2. Open the storage tank valve to disinfect the tank.
3. Bleed the air from the system by opening the RO faucet until

water comes out of it. Immediately shut off the RO faucet.

4. Let the system stand for 10 minutes.
5. Open the RO faucet and flush the system for 10 minutes.
6. Turn off the water supply and open the RO faucet until the

system pressure has been released. Close the RO faucet.

D. Replace the Filters.

1. Remove both Pre-filter tanks and empty the water out of

them.

2. Follow Steps 7 through 9 under “Pre-Filter Cartridge Change

(TO1 and CB1)”, Page 4.

3. Follow Steps 1 through 4 under “Post Filter Removal and

Installation”, Page 4.

4. Carefully pull the RO membrane housing out of its 

brackets.

5. Place a bucket under the membrane housing. Unscrew the

membrane housing cap and dump all the water into the
bucket.

E. Re-install the RO Membrane.

1. Follow Steps 1 through 5 under “RO Membrane Installation”,

Pages 3 and 4. Before replacing the membrane housing Cap,
re-lubricate the O-Ring with vegetable oil.

2. Unscrew the compression nut holding the black tube onto

the membrane housing.

3. Gently remove the tube from the membrane housing port;

keep the nut on the tube.

4. Remove and discard the flow restrictor from the end of the

black tube (see Figure 10).

5. Install the new flow restrictor in the end of the tubing as

shown in Figure 10. Make sure that the collar on the flow
restrictor seats against the end of the tube.

NOTICE:

Do not cut the flow restrictor.

6. Insert the black tube approximately 3/8” into the port on the

membrane housing and screw on the compression nut until it
is firmly hand tight.

7. Snap the new Post filter into its brackets on the RO mem-

brane housing (large end toward the membrane housing
cap).

F.

Flush the System Before Using.

1. Put the RO unit back under the sink. Open the faucet and the

saddle valve. Flush the system to waste for one hour. Fill and
dump the storage tank to waste twice.

2. Charge the system for at least 6 hours. Periodically check for

leaks. 

3. Open the RO faucet and let the water run until the air and

carbon fines are out of the system. Close the faucet.

4. Charge the system for a minimum of another 6 hours.

Your system is now ready for use.

NOTICE:

For units equipped with Total Dissolved Solids (TDS) moni-

tor: The TDS monitor is designed to detect the presence of TDS
only. 

Do not

rely on the TDS monitor to warn of the presence of

bacterial or other organic substances in the system.

The TDS monitor checks the conductivity of filtered drinking water
each time the RO faucet is used. It displays a green light on the LED
in the faucet if the TDS level of the water is below the set point,
and an amber light if the TDS level is above the set point.

This RO unit must be used only on the cold water line.

RO units work best at a neutral pH (7.0).

Pressure limits: Minimum 40 psi, Maximum 100 psi.

Temperature limits: Minimum 40° F (4° C), Maximum 100° F (38° C).

Sanitize the system at every membrane change (when replacing all
filter cartridges). This should be done every 2 years or whenever
daily water production is greatly reduced. The condition of the sup-
ply water to your unit will directly affect membrane life.

Most newer sinks have a 1-3/8” or 1-1/2” hole through the sink
top. If your sink does not have such a hole, or if it is already in use,
the installer must drill (or punch) a 1-1/8” hole in the sink top
before installing the RO unit.

5

3638 0100

Flow
Restrictor

Waste Water
Tube

Figure 10: Flow Restrictor

IN

OUT

From Membrane
(Product Water)

From Pre-Filter
(Supply Water)

To Tee/Post Filter
(Product Water)

To Membrane
(Supply Water)

3640 0100

Figure 11: Flow Controller Tubing Connections. Please See
Exploded View, Page  6.

Содержание RO2000 Series

Страница 1: ...ssary drill or punch a 1 1 8 hole in the sink top 3 Remove the nut and spacer from the RO faucet and feed the two lengths of black tubing attached to the faucet stem down through the hole in the sink top until the faucet is seated on the sink top The vertical ridge on the faucet handle should be facing toward the user 4 Reach below the sink top and slide the channel washer up the faucet stem Insta...

Страница 2: ...ough the wall of the supply line Do not force it and do not overtighten REVERSE OSMOSIS RO UNIT ASSEMBLY AND INSTALLATION 1 Place the storage tank in a convenient location under the sink Make sure that the tank valve is OPEN See Figure 4 2 Place the RO unit in a shallow pan on the floor in front of the sink 3 Connect the free end of the 1 4 black tube out of the faucet to the compression fitting c...

Страница 3: ...itor Be sure that the connection ports on the electronics enclosure face down 2 Run the grey telephone style cable with the yellow plug from the RO faucet to the right hand yellow port on the TDS Monitor 3 Run the grey telephone style cable from the white flow switch to the left hand port on the TDS Monitor 4 Remove the lid from the monitor and install a 9 volt battery pur chase separately Use a p...

Страница 4: ...any tubing 5 Using the plastic tank wrench supplied remove Pre Filter Tanks TO1 and CB1 Be careful the tanks will be full of water 6 Remove the used cartridges and dispose of them 7 Check the tank O Rings to be sure that they are seated properly Apply vegetable oil to the O Rings 8 Rinse the tanks with clear water no soap and wipe them out with a clean rag or paper towel 9 Put the replacement filt...

Страница 5: ...e the O Ring with vegetable oil 2 Unscrew the compression nut holding the black tube onto the membrane housing 3 Gently remove the tube from the membrane housing port keep the nut on the tube 4 Remove and discard the flow restrictor from the end of the black tube see Figure 10 5 Install the new flow restrictor in the end of the tubing as shown in Figure 10 Make sure that the collar on the flow res...

Страница 6: ...I NSF Standard 58 for the reduction of Fluoride Cysts Lead TDS Nitrate and Nitrite For further operating installation or maintenance assistance Call Omnifilter Customer Service at 800 937 6664 The Chlorine claim was tested off of the R200 post filter NOTICES Daily production rate is 13 gpd The reverse osmosis system contains a replaceable treatment component critical for the effective reduction of...

Страница 7: ...orter à la Figure 1 1 Fermer le robinet d arrivée d eau froide 2 Au besoin percer ou perforer un trou de 1 1 8 pouce dans le dessus de l évier 3 Déposer l écrou et l entretoise du robinet d eau traitée de l évier et faire passer les deux tubes noirs branchés sur la tige du robinet dans le trou de l évier jusqu à ce que le robinet repose sur l évier La saillie verticale de la poignée du robinet doi...

Страница 8: ...asser à l opération 5 Dans le cas du modèle RO2000 TDS passer à l opération 4 qui suit 4 Visser le contacteur débitmétrique blanc sur l extrémité du robinet se reporter à la Figure 6 A Piercing Needle Cold Water Pipe B C 3631 0100 Secure the Saddle Valve by tightening the nuts and bolts Turn handle clockwise to pierce the supply line with the piercing needle Figure 3 Installation du robinet à étri...

Страница 9: ...dans un endroit pratique sur le mur à l aide des attaches autoadhésives du module de contrôle S assurer que les orifices de branchement du boîtier électron ique sont orientés vers le bas 2 Amener le câble gris de type téléphone muni d une prise jaune branché sur le robinet d eau traitée de l évier jusqu à l orifice jaune qui se trouve à droite du module de contrôle des matières totales dissoutes 3...

Страница 10: ... d eau traitée et les mettre dans un bac creux sur le plancher à l avant de l évier NOTA Ne débrancher aucun tube 5 À l aide de la clé en plastique fournie déposer les cuves des cartouches préfiltrantes TO1 et CB1 Prudence les cuves sont pleines d eau 6 Sortir les cartouches filtrantes puis les jeter 7 Vérifier les joints toriques des cuves et s assurer qu ils reposent adéquate ment Appliquer de l...

Страница 11: ...ice de la cuve de la membrane laisser l écrou sur le tube 4 Déposer et jeter le limiteur de débit de l extrémité du tube noir se reporter à la Figure 10 5 Poser le limiteur de débit neuf dans l extrémité du tube comme il est illustré à la Figure 10 S assurer que le rebord du limiteur de débit repose contre l extrémité du tube NOTA Ne pas couper le limiteur de débit 6 Introduire le tube noir d envi...

Страница 12: ...SF en ce qui concerne la réduction de fluore de kystes de plomb de matières totales dissoutes de nitrate et de nitrite Pour tout autre renseignement concernant le fonctionnement l installation ou l entretien Appeler le service à la clientèle Omnifilter en composant le 800 937 6664 La réduction de chlore a été testée avec une cartouche postfiltrante R200 NOTA La production journalière d eau traitée...

Страница 13: ...del fregadero 3 Saque la tuerca y el espaciador del grifo de OI y haga pasar dos largos del tubo negro conectado al vástago del grifo hacia abajo por el orificio en la parte superior del fregadero hasta que el grifo quede asentado sobre la parte superior del fregadero La protuberancia vertical del mango del grifo debe quedar mirando hacia el usuario 4 Debajo de la parte superior del fregadero haga...

Страница 14: ...lo RO2000 vaya al paso 5 Para el Modelo RO2000 TDS vaya al paso 4 a continuación 4 Enrosque el conmutador de flujo blanco al extremo del grifo ver Figura 6 14 A Piercing Needle Cold Water Pipe B C 3631 0100 Secure the Saddle Valve by tightening the nuts and bolts Turn handle clockwise to pierce the supply line with the piercing needle Figura 3 Instalación de la Llave de Silla para Agua Fría Shut O...

Страница 15: ... monitor Asegúrese de que las aberturas de conexión en el recinto electrónico estén mirando hacia abajo 2 Haga correr el cable gris tipo telefónico con el enchufe amarillo desde el grifo de OI a la abertura derecha amarilla en el Monitor TDS 3 Haga correr el cable gris tipo telefónico desde el conmutador blanco de flujo a la abertura izquierda en el Monitor TDS 4 Saque la tapa del monitor e instal...

Страница 16: ...uercas para tanques de plástico suministrada saque los Tanques de Prefiltración TO1 y CB1 Tenga cuidado ya que los tan ques estarán llenos de agua 6 Saque los cartuchos usados y deséchelos 7 Inspeccione los aros tóricos del tanque para asegurarse de que estén debidamente acomodados Aplique aceite vegetal en los aros tóricos 8 Enjuague los tanques con agua limpia sin jabón y séquelos con un paño li...

Страница 17: ...embrana 3 Delicadamente retire el tubo de la abertura de la envoltura de la membrana manteniendo la tuerca en el tubo 4 Saque y deseche el restrictor de flujo del extremo del tubo negro ver Figura 10 5 Instale el nuevo restrictor de flujo en el extremo de la tubería según se ilustra en la Figura 9 Asegúrese de que el collarín en el restrictor de flujo quede acomodado contra el extremo del tubo AVI...

Страница 18: ...uro esporas plomo TDS Nitrato y Nitrito Para mayor asistencia sobre el funcionamiento instalación o mantenimiento Llame al departamento de servicio al cliente de Omnifilter al 800 937 6664 La reivindicación sobre el cloro no fue incluida en la prueba del postfiltro R200 AVISOS La tasa de producción diaria es de 13 gpd El sistema de osmosis inversa contiene un componente de tratamien to reemplazabl...

Страница 19: ...19 ...

Страница 20: ...20 ...

Отзывы: