It is not recommended to use self-tapping screws to fix the product onto a metal or
plastic tank with the wall sickness under 3mm. This type of fixation cannot ensure
reliability of product attachment to the tank.
b. Metal tank with wall thickness over 3mm
Prepare the tank for product installation on a threaded joint.
The tanks which shape corresponds with the figure (Figure 2) should be prepared in
accordance with Appendix E.
Drill holes in the tank: the central hole - by a bi-metal crown ø35mm and mounting
holes - by a drill ø4mm as shown in the figure (Figure 8).
Make an М5 thread with the help of an М5 tap.