2) On the working length of the product L, measure length L1 equal to the depth of
the tank minus 20mm.
Minimum allowable length of the measuring probe cutting is 150 mm.
4) Cut the product at length L1 by a hack-saw so that the line of the cut is strictly
perpendicular to the longitudinal axis of the product (Figure 10).
5) Fill the 1/4 to 1/5 of the sealing cap with a sealant (supplied). Recommended
sealants are listed in the Appendix J.
6) Put the plastic isolating cap included into the product delivery set on the central
rod of the product.
Note: When using the sensor without cutting, it is necessary to take off the rubber
transportation cap and put on the plastic isolating cap using sealant.
Setting the Product with Omnicomm Configurator
Connect the Product to the PC following the connection diagram (see Appendix E),
using the REUSABLE TOOL-UNU (Figure 11) or Omnicomm UNU-USB (Figure 12).
11
Abbreviations and Symbols