Err07
Current limiting resistor break
Problem with black tablet (power resistor)
(contact assistance)
Err08
Low Voltage Table Inverter
Problem with table inverter relating to low bus
voltage
Err09
High Temperature Table
Inverter
Problem with high temperature of table inverter
Err10
High Voltage Table Inverter
Problem with high tension Table Inverter
Err11
Maximum Current Table Inverter Problem with inverter high current table
Err12
Short Circuit Table Inverter
Problem with Inverter table short circuit
Err13
Inverter Table I2T
Problem with inverter table with maximum
thermal current I2T
Err14
Low Voltage Inverter Carriage
Problem inverter carriage relating to low bus
voltage
Err15
High Temperature Inverter
Carriage
Problem with high temperature of carriage
inverter
Err16
High Voltage Inverter Carriage Problem high Voltage Inverter Carriage
Err17
Maximum Current Carriage
Inverter
Problem with inverter high current table
Err18
Short Circuit Inverter Carriage
Problem inverter carriage short circuit
Err19
Inverter Carriage I2T
Problem inverter carriage with maximum
thermal current I2T
Err20
Carriage out of position
If the pallet moves during wrapping (G21 = 02
“machine Motus”) and the parameter G20 is
enabled, this error is generated
Err21
YoYo Fail
If during reset, while going down, the carriage
meets the low limit switch before the YoYo
sensor, this error is generated (G21 = 02
“machine Motus”)
CARRIAGE SAFETY LIMIT SWITCH
If the carriage safety limit switch is pressed due to an obstacle, then, the carriage blocks instantly
and goes up until the limit switch is unblocked and the machine passes automatically in the Manual
mode. The display shows the wording “-SiC-“ and a prolonged acoustic warning is emitted.