Electromagnetic Compliance

Manufacturer’s declaration of electromagnetic immunity

Immunity test IEC 60601 

test level

Compli-

ance level

Electromagnetic 

environment - 

guidance

Portable and mobile RF communications equipment should 

be used no closer to any part of the OML LINQ™, including 

cables, than the recommended separation distance calculated 

from the equation applicable to the frequency of the transmitter.
Conducted RF 

IEC 61000-4-6

3 Vrms 

(150kHz 

to 80MHz)
6 Vrms in 

ISM bands

3 Vrms 

(150kHz to 

80MHz)
6 Vrms in 

ISM bands

Recommended 

separation distance:

d = 1.2 * √P

Radiated RF

IEC 61000-4-3

10 V/m
80 Mhz to 

2.5 GHz

10 V/m

Recommended 

separation distance:

d = 1.2 * √P  (80Mhz 

to 800MHz)

d = 2.3 * √P   

(800MHz to 2.5GHz)

Note 1: Where (P) is the maximum output rating of the transmitter in watts (W) according to the 
transmitter manufacturer and (d) is the recommended separation distance in metres (m).

Note 2: Field strengths from fixed RF transmitters, as determined by an electromagnetic site survey,

a

 

should be less than the compliance level in each frequency range

b

. Interference may occur in the 

vicinity of equipment marked with the following symbol.
Note 3: At 80 MHz and 800 MHz, higher frequency range applies. 

Note 4: These guidelines may not apply in all situations. Electromagnetic propagation is affected by 
absorption and reflection from structures, objects and people.

a

 

Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones 

and land mobile radios, amateur radio, AM and FM radio broadcast and TV broadcast cannot be 

predicted theoretically with accuracy. To assess the electromagnetic environment due to fixed RF 
transmitters, an electromagnetic site survey should be considered. If the measured field strength in 

which the OML LINQ™ is used, exceeds the applicable RF compliance level above, the OML LINQ™ 
should be observed to verify normal operation. If abnormal performance is observed, additional 
measures may be necessary, such as re-orientating or relocating the OML LINQ™.

b

 

Over the frequency range 150 kHz to 80 MHz, field strengths should be less than 3 V/m.

Содержание LINQ 1.0

Страница 1: ...Odstock Medical Limited To be used in conjunction with the OML Stimulator Instruction Manual www odstockmedical com USER INSTRUCTION MANUAL OML LINQTM Model OML LINQTM Model Version 1 0 Software V1 2...

Страница 2: ...ing the Holder 7 Installing a Battery 8 Joining Instructions 10 Installing a Wired Footswitch 12 Use and Care Instructions 13 Miscellaneous 14 Warranty 15 Components and Accessories 16 Specification a...

Страница 3: ...two Wired Footswitches attached allowing for additional triggering options refer to the OML LINQTM Addendum for Clinicians The OML LINQTM has been designed to allow the user to set the device up with...

Страница 4: ...tch if lead becomes stiff or damaged 4 Warning battery may explode if mistreated Do not recharge disassemble or dispose of in fire 5 The OML LINQTM should be securely mounted especially if used for jo...

Страница 5: ...hibited e g aircraft The OML LINQTM should be carried in luggage with the battery removed from the device Revert to using the stimulator with a Wired Footswitch 13 Whilst driving ensure that the OML L...

Страница 6: ...e of the device The Holder allows the OML LINQTM to be attached to the side of a shoe or sock Ensure that it is securely attached before use When removing the Holder from the shoe be careful not to ov...

Страница 7: ...7 1 Pull either arm of the Holder away from the OML LINQTM 2 Gently lift the Holder away from the OML LINQTM Removing the Holder...

Страница 8: ...se refer to image A and B 4 If present then remove the old battery 5 Install the new battery with the positive side of the battery facing out from the OML LINQTM If installed correctly the blue light...

Страница 9: ...9 A C D B...

Страница 10: ...ator refer to stimulator user instruction manual or OML LINQTM Joining to ODFS Pace XL quick start card supplied 4 When the stimulator indicates that it is waiting to join this will time out after 1 m...

Страница 11: ...11 Flashing Blue Light Joining in Progress Joining Button Single Press...

Страница 12: ...ur shoe insole for reliable operation If using a single footswitch it does not matter which socket the footswitch is inserted into NB Two Odstock Medical Wired Footswitches can be used on the OML LINQ...

Страница 13: ...or use solvents If the OML LINQTM becomes wet please remove the battery cover and battery and allow to air dry thoroughly for 24 hours before re use If unresponsive contact Odstock Medical Limited Exp...

Страница 14: ...not to be used for an extended period i e 1 month then remove the coin cell battery Close Proximity Joining Close proximity joining is used if many devices are being joined at the same time in a confi...

Страница 15: ...uld the failure be due to manufacturing or material defect the device will be repaired or a replacement supplied free of charge The warranty is valid providing that 1 The failure can not be attributed...

Страница 16: ...1 0004 1 Universal Foam Insole 01 005 0043 1 Optional Extras and Spares Description Product Code Footswitch length options Black Wired Footswitch 22cm 01 005 0044 for standard footwear Black Wired Foo...

Страница 17: ...erature 25 to 70 o C Operating Relative Humidity 15 to 93 Storage and Transport Relative Humidity 15 to 93 Pressure Range 700 to 1060hPa Wireless Specification Frequency Band 2 4 to 2 483GHz 2 4GHz IS...

Страница 18: ...L LINQ TM not properly inserted 2 Slots dirty 3 Holder broken Please refer to instructions on page 6 Clean slots Replace Holder Stimulator unpauses but is not triggered by the wired footswitch 1 Wired...

Страница 19: ...objects of greater than 2 5mm and dripping water at an angle up to 15 degrees The OML LINQTM should not be disposed of with other household waste CR2430 The OML LINQTM uses a CR2430 coin cell battery...

Страница 20: ...15 USA meeting the requirements for modular transmitter approval as detailed in FCC public notice DA00 107 Transmitter Quality of service The OML LINQ is designed and tested to have a response rate o...

Страница 21: ...the OML LINQ page 8 Wireless Communication indications On pausing the stimulator the wireless connection is confirmed by display of a battery level for the footswitch If the connection Is not found t...

Страница 22: ...l function Therefore its RF emissions are very low and are not likely to cause any interference in nearby electronic equipment Radiated Spurious Emissions ETSI EN 300 328 V2 1 1 Clause 5 4 9 30MHz to...

Страница 23: ...kV contact 15kV air Floors should be wood concrete or ceramic tile If floors are covered with synthetic material the relative humidity should be at least 30 Electrical fast transient burst IEC 6100 4...

Страница 24: ...by an electromagnetic site survey a should be less than the compliance level in each frequency rangeb Interference may occur in the vicinity of equipment marked with the following symbol Note 3 At 80...

Страница 25: ...itter m 150 kHz to 80 MHz d 1 2 P 80 MHz to 800 MHz d 1 2 P 800MHz to 2 5GHz d 2 3 P 0 01 0 12 0 12 0 23 0 1 0 38 0 38 0 73 1 1 20 1 20 2 30 10 3 79 3 79 7 27 100 12 0 12 0 23 0 For transmitters rated...

Страница 26: ...ed by local regulations Any adverse incidences or regulatory problems should be reported via local representative If in doubt please contact Odstock Medical Limited for advice EU Emergo Europe Prinses...

Страница 27: ...27 Notes Local contact information may be placed here...

Страница 28: ...Hospital Salisbury Wiltshire SP2 8BJ United Kingdom Tel 44 0 1722 439540 www odstockmedical com enquiries odstockmedical com Registered Company No 5532620 Manual Revision V5 0 Manual Part Number 11 00...

Отзывы: