background image

ENGLISH

Intended use

 The Philips Avent Nipple Shield is intended 

to cover and protect the nipples of lactating women 
to support breastfeeding. The device is intended for 
a single user.

Indications for use

 The Philips Avent Nipple Shield is 

indicated for use when the mother has sore, sensitive, 
cracked nipples or suffers from nipple pain. It is also 
indicated to help the baby develop better latch-on 
behavior in case of oral anomalies or when the mother 
has flat/inverted nipples. Moreover, it can be used to 
alleviate milk supply difficulties when the baby is not 
transferring the milk well, has an uncommon sucking 
technique (i.e. weak sucking, small/preterm babies) or to 
help the baby in coping with milk flow.

Contraindications

 There are no contraindications.

Side effects

 When using the device, undesirable side effects 

that may occur are mastitis, cessation of breastfeeding, 
infant thrush and poor infant weight gain. If you or your 
baby experience any of these symptoms, contact a 
healthcare professional or breastfeeding specialist.

Important safety information

Read this important information carefully before you use 
the product and save it for future reference.

  

Warning to avoid choking and swallowing

 

-

Never leave the nipple shield and the hygiene case 
unattended and keep out of reach of children.

 

-

Inspect before each use. Throw away at the first signs 
of damage or weakness or after 2 months of usage.

   

Warning to avoid contamination and to ensure hygiene

 

-

Follow the instructions described in the Cleaning and 
Disinfection sections.

Recommendations

 

-

Use the product only in case of breastfeeding 
problems as described in the Indications For Use.

 

-

Recommended to be used with advice from health 
care professional. If problems or pain occur, consult 
your lactation consultant or physician.

 

-

An electronic copy of these instructions can be found 
at 

www.philips.com/support

.

 

-

Any serious incident that has occurred in relation  
to this device should be reported to Philips via  

www.philips.com/support

 and to the competent 

authority of the Member State in which the user  
and/or patient is established.

Before usage

Step 1 - Cleaning 

   

Warning

Do not use abrasive cleaning agents or aggressive 
chemicals or substances when you clean the nipple 
shield. Clean the nipple shield and hygiene case before 
first use and immediately after each use.

Manual cleaning

1

   Rinse with drinking-quality water for 10-15 seconds.

2

   Wash in warm, drinking-quality water (approx. 35 °C) 

with washing-up liquid, preferably without artificial 
fragrances or coloring.

 

3

   Rinse with drinking-quality water for 10-15 seconds. 

4

  

Dry with a clean cloth or leave to dry on a clean 
surface.

Dishwasher cleaning

 

1

   Place on top rack of the dishwasher. 

2

   Run standard program with common household 

dishwasher detergent. 

3

   If not fully dry after dishwasher program, dry with a 

clean cloth or leave to dry on a clean surface.

Step 2 - Disinfection

 

Warning

Disinfect before first use and at least once a day. Clean 
before disinfection.
Be careful: After disinfection, the nipple shields may be 
very hot. The hygiene case and the water remaining in 
the case may still be hot. To prevent burns, only use after 
cooling down for 5 minutes.

 

Warnings to avoid contamination and to ensure hygiene

If you use the hygiene case for disinfection: 
-  Clean the case before first use. 
-   Use the correct water level, microwave power and 

time. Not doing so can lead to reduced disinfection 
and can damage the case or nipple shields. 

-   Only use the case provided.

Boiling

1

   Clean as described under ‚Cleaning‘. 

2

   Boil the nipple shields in drinking-quality water for  

5 minutes. 

3

   Leave to dry on a clean surface.

Microwave

 - Alternatively, use only the hygiene case 

provided according to the instructions below. 

1

   Clean the hygiene case (as described under ‚Cleaning‘). 

2

   Add 25 ml of drinking-quality water to the case, up to 

the indicated line (Fig. 1). 

3

   Place the nipple shield(s) in the hygiene case and 

securely close the lid (Fig. 2). 

4

   Place the filled hygiene case in the microwave for  

3 minutes at 750-1000 W (Fig. 3). 

5

   Let the hygiene case cool down for 5 minutes (Fig.4).

6

   Drain water from the hygiene case (Fig.5). 

7

   Dry the nipple shield(s) with a clean cloth or leave to 

dry on a clean surface.

Usage

 

Warning

Wash your hands and breasts thoroughly with soap and 
water before you touch the nipple shields to prevent 
contamination.

Applying the product

 - Follow the instructions below 

when placing the device on your breast: 

1  

Remove the cleaned and disinfected nipple shield 
from the hygiene case. 

2

   Place drinking-quality water or breast milk on the 

skin-facing side of the brim to help the shield stick  
to your skin (Fig. 6). 

3  

Hold the shield at the base of the nipple area and 
press the nipple cavity partially inside out, so that it 
becomes half way inverted (Fig. 7). 

4  

Rotate the shield so that the baby can have nose and 
chin contact with your breast skin (Fig. 8). 

5  

Center the shield over your nipple and slightly stretch 
the wings of the shield as you stick the product onto 
your breast (Fig. 9). 

6  

With the shield applied, you can now breastfeed as 
normal.

Storing

 Store the clean nipple shield(s) in the hygiene 

case or in a dry, clean container. Storing the nipple 
shield(s) in an unclean or wet container could cause 
contamination.

Disposal

  According to local regulations.

Explanation of symbols

The warning signs and symbols are essential to ensure 
that you use this product safely and correctly and to 
protect you and others from injury. Below you find the 
meaning of the warning signs and symbols on the label 
and in the user manual.

This symbol indicates that the device 
complies with European Medical Device Directive 
93/42/EEC requirements.

This symbol indicates the hygiene case is 
microwave compatible.

This symbol indicates to fill the hygiene case 
with water.

This symbol indicates to wait 5 minutes before 
taking the hygiene case out of the microwave.

Indicates the storage and transportation 
temperature limits to which the medical device can 
be safely exposed: -25 °C/-13 °F to +70 °C/+158 °F.

The 5 inside this symbol is the recycling code 
used to identify the material from which the 
hygiene case is made, which is polypropylene 
(PP), to facilitate recycling or other reprocessing.

The Green Dot (‚Der Grüne Punkt‘ in German) 
is the license symbol of a European network 
of industry-funded systems for recycling the 
packaging materials of consumer goods.

Technical specifications

 

-

 Product type: Two type nipple shield size:  
Small 15 mm; Medium: 21 mm.

 

-

 Materials: Silicone (nipple shield); Polypropylene 
(hygiene case)

 

-

Service life: 2 months

ESPAÑOL

Uso previsto

 el protector de los pezones Philips AVENT 

está diseñado para cubrir y proteger los pezones de las 
mujeres lactantes para apoyar la lactancia materna. Este 
dispositivo está diseñado para un solo usuario.

Indicaciones de uso

 el protector de los pezones Philips 

AVENT está indicado para el uso cuando la madre tiene 
los pezones doloridos, sensibles o agrietados. También 
está indicado para ayudar al bebé a agarrarse mejor en 
caso de anomalías orales o si la madre tiene los pezones 
planos o invertidos. También se puede utilizar para aliviar 
las dificultades del suministro de leche cuando el bebé 
no transfiere la leche correctamente, tiene una forma 
de succión poco habitual (por ejemplo, bebés con poca 
fuerza, bebés pequeños o prematuros) o para ayudar al 
bebé a manejar el flujo de leche.

Contraindicaciones

 no hay contraindicaciones.

Efectos

 secundarios al utilizar el dispositivo, pueden 

ocurrir efectos secundarios indeseables, como 
mastitis, cese de la lactancia materna, aftas en el bebé y 
poco aumento de peso en el bebé. Si usted  o su bebé  
experimentan alguno de estos síntomas, consulte con un 
asesor en lactancia o profesional de la salud.

Información de seguridad importante

Antes de usar el producto, lea atentamente esta 
información importante y consérvela por si necesitara 
consultarla en el futuro.

 

Advertencia para evitar la asfixia y la ingestión

 

-

No deje nunca el protector de pezones y el estuche 
de higiene desatendidos y manténgalos fuera del 
alcance de los niños.

 

-

Compruebe todos los elementos antes de cada uso. 
Deseche el producto a los primeros signos de daños 
o debilidad, o después de 2 meses de uso.

  

Advertencia para evitar la contaminación y 

garantizar la higiene

 

-

Siga las instrucciones descritas en las secciones sobre 
limpieza y desinfección.

Recomendaciones

 

-

Utilice el producto solo en caso de problemas de 
lactancia, tal como se describe en las indicaciones 
de uso.

 

-

Se recomienda utilizarlo con el asesoramiento de un 
profesional sanitario. Si surgen problemas o dolor, 
consulte con su médico o consultor de lactancia.

 

-

Puede encontrar una copia electrónica de estas 
instrucciones en

 www.philips.com/support

.

 

-

Cualquier incidente grave que haya ocurrido en 
relación con este dispositivo deberá notificarse a 
Philips a través de 

www.philips.com/support

 y a la 

autoridad competente del estado miembro en el que 
residan el usuario y/o el paciente.

Antes del uso

Paso 1: Limpieza 

 

Advertencia

No utilice agentes limpiadores abrasivos ni sustancias 
químicas o productos agresivos al limpiar el protector de 
los pezones. Limpie el protector del pezón y el estuche 
de higiene antes del primer uso e inmediatamente 
después de cada uso.

Limpieza manual

1

  

Enjuagar con agua potable durante 10-15 segundos. 

2

  

Lavar en agua potable tibia (aproximadamente 35 °C) 
con jabón líquido, preferiblemente sin aromas ni 
colorantes artificiales. 

3

  

Enjuagar con agua potable durante 10-15 segundos. 

4

  

Secar con un paño limpio o dejar secar el producto 
sobre una superficie limpia.

Limpieza en el lavavajillas

1

  

Colocar en el estante superior del lavavajillas. 

2

  

Ejecutar un programa estándar con detergente para 
lavavajillas doméstico común. 

3

  

Si no está completamente seco después del programa 
del lavavajillas, secar con un paño limpio o dejar secar 
sobre una superficie limpia.

Paso 2: Desinfección

 

Advertencia

Desinfectar antes del primer uso y al menos una vez al 
día. Limpiar antes de desinfectar.
Tenga cuidado: Después de la desinfección, los 
protectores de los pezones pueden estar muy calientes. 
El estuche de higiene y el agua restante en el estuche 
pueden estar todavía calientes. Para evitar quemaduras, 
utilice el producto solo después de enfriarlo durante 
5 minutos.

–13°F

–25°C

158°F

70°C

750 – 1000W

3 min.

3

5

8

6

9

25 ml/

0.9 fl.oz

1

2

5 min.

4

7

SCF153/01

SCF153/03

 Philips Consumer Lifestyle BV

Tussendiepen 4, 9206 AD Drachten, The Netherlands
www.philips.com/avent

Trademarks are the property of Koninklijke Philips N.V.
© 2019 Koninklijke Philips N.V.
All rights reserved.
3000.038.9739.2 (24/10/2019)