Cleaning and Maintenance
45
Maintenance
Calibration
It is a requirement that the OmiSmoke is calibrated once a year, or as directed from
time to time by the Vehicle inspectorate Executive Agency in the United Kingdom.
This calibration must be carried out by UKAS approved engineers.
For further information, please contact your supplier or the manufacturer.
Replacing the printer paper
The part number for replacement paper is PE2008A, however the printer paper can
be replaced with any thermal printer paper roll which is between 57-58 mm wide and
has a maximum diameter of 49.5 mm.
To replace the printer paper:
1.
Lift green release clip and open paper compartment lid.
2.
Remove old paper cartridge.
3.
Insert new paper roll.
4.
Feed a short length of paper through and close paper compartment lid.
Replacing the battery
Rechargable batteries have a limited life, and eventually need replacing. If the
smokemeter’s battery needs replacing follow this procedure:
1.
Carefully place the smokemeter on it’s back and locate the battery compartment
cover on the base of the unit.
2.
Remove two screws to release battery compartment.
3.
Slide out battery compartment and release battery leads.
4.
Remove battery from battery compartment.
Note: Ensure the battery is disposed of in accordance with current rules and
regulations applicable and enforced in your area.
5.
Fit new battery in battery compartment and fit battery leads to terminals.
Note: Ensure the battery leads are fitted to the correct battery terminals.
6.
Replace battery compartment and secure with screws.
7.
Charge battery (see Information section).