Fault
Possible cause
Remedy
LED "Searching/Locked"
has been flashing for
approx. 20 minutes,
CMGPS cannot be
successfully locked to
the GPS signal (TTFF
considerably exceeded).
Cable connection
antenna
⇔
CMGPS
defective.
Check screwed fittings
and contact quality of the
coaxial cable at each
connection.
Position of antenna
inappropriate.
Place antenna in a more
exposed location that
provides sufficient open
sky.
Antenna or antenna
cable defective.
Replace defective
component.
Malfunction of the
CMGPS.
Please contact the
OMICRON Technical
Support (see ”Contact
Information / Technical
Support” on page 45).
Fault
Possible cause
Remedy
LED "Searching/Locked"
is lit, CMGPS is locked
to the GPS signal, but
there is no
synchronization pulse.
Timing parameter for
putting out the
synchronization pulse is
set wrong or too long.
Check the settings by
means of the software. If
necessary change
settings.
Malfunction of the
CMGPS.
Please contact the
OMICRON Technical
Support (see ”Contact
Information / Technical
Support” on page 45).
Содержание CMGPS
Страница 1: ...27 CMGPS Synchronization Unit Reference Manual...
Страница 8: ...GPS Synchronization Unit CMGPS 8...
Страница 10: ...GPS Synchronization Unit CMGPS 10...
Страница 24: ...GPS Synchronization Unit CMGPS 24...
Страница 28: ...GPS Synchronization Unit CMGPS 28...
Страница 34: ...GPS Syncronization Unit CMGPS 34...
Страница 46: ...Contact Information Technical Support 46...