Legend - Légende: 

 

Pos. 

- GB -  DESCRIPTION 

- F - DESCRIPTION   

Pos. 

- GB - DESCRIPTION 

- F -  DESCRIPTION 

AR 

Air flow rate 

Performances 

 

AMB T MIN-

MAX 

Min-Max. ambient 

temperature 

Temp. Ambiante min-

max. 

POW SUPPLY 

Power supply 

Alimentation 

 

AIR W PRESS 

Air working pressure 

Pression travail d’air 

HP 

Nominal power 

Puissance nom. 

 

AIR PRESS 

MAX 

Max. air pressure 

Pression max. d’air 

kW 

Nominal consumption 

Consommation nom. 

 

DEWP 

Pressure dew point 

Pression pt de rosée 

Max kW 

Full load consumption 

Cons. pleine charge 

 

REF 

Refrigerant 

Réfrigérant 

RLA 

Nominal Current 

Ampère nominale 

 

MAX FUSE 

Max fuse size 

Maximum fusibles 

FLA 

Full load current 

Ampère pl. charge 

 

MIN CIRCUIT 

AMPACITY 

Minimum circuit 

ampacity 

Minimum courant 

électrique 

LRA 

Locked rotor current 

Ampère max. 

 

Weight 

Poids 

TOTAL A

 

Total current 

Ampère total 

 

EVAP. TEMP 

Evaporation 

Temperature

 

Température 

d'évaporation 

CONNECTION 

Air connections 

Connexion aircomp. 

 

SUCTION TEMP 

Suction Temperature

 

Température 

d'aspiration 

AIR T 

Air inlet temperature 

Temp. entrée d’air 

 

DISCH. PRESS. 

Discharge Pressure

 

Pression de décharge 

AIR T MAX 

Max. air inlet temperature 

Temp. entrée d’air 

max. 

 

HP SWITCH 

SETTING 

High pressure switch 

setting 

Réglage du pressostat 

de haute pression 

AMB T 

Ambient temperature 

Temp. ambiante 

 

 

 

 

 

 

D) CORRECTION FACTORS - FACTEURS DE CORRECTION 

Correction factor for working pressure - Facteur de correction pour la pression du travail 

bar 

10 

11 

12 

13 

14 

psi 

73 

87 

102 

116 

131 

145 

160 

174 

188,5 

203 

FC1 

0,85 

0,93 

1,06 

1,11 

1,15 

1,18 

1,2 

1,22 

1,24 

Correction factor for inlet air temperature - Facteur de correction pour la température de l'air d'entrée 

°C 

26,5 

32 

37,8 

43,5 

49 

54,5 

60 

 

 

 

°F 

80 

90 

100 

110 

120 

130 

140 

 

 

 

FC3 

1,3 

1,18 

0,8 

0,6 

0,42 

0,25 

 

 

 

Correction factor for ambient temperature- Facteur de correction pour la température ambiante 

°C 

26,5 

32 

37,8 

40,5 

43,5 

50 

 

 

 

 

°F 

80 

90 

100 

105 

110 

122 

 

 

 

 

FC2 

1,1 

1,05 

0,93 

0,83 

0,65 

 

 

 

 

 

Calculation of the dryer REAL FLOW RATE = nominal dryer flow rate x FC1 x FC2 x FC3 
Calcul du DÉBIT RÉEL du séchoir = débit nominal du séchoir x FC1 x FC2 x FC3 

 

Calculation of the GIVEN FLOW RATE to select a suitable dryer = given flow rate ÷ FC1 ÷ FC2 ÷ FC3 
Calcul du DÉBIT DONNÉ pour sélectionner un séchoir approprié = débit donné ÷ FC1 ÷ FC2 ÷ FC3 

Содержание ED24-SR

Страница 1: ...EN DIRECT EXPANSION COMPRESSED AIR DRYERS Operators Manual For 60 Hz dryers NPT version FR SECHEUR D AIR A EXPANSION DIRECTE Manuel des Op rateurs Pour des s cheurs 60 Hz NPT version ED18 ED24 SR ED5...

Страница 2: ...Factors 25 E Dryer Dimensions 26 F Basic Spare Parts 28 FR TABLE DES MATIERES 1 INFORMATIONS GENERALES 1 1 Description fonctionnelle 12 1 2 Utilisation du s choir en toute s curit 12 2 INSTALLATION 2...

Страница 3: ...essure and to refer to the Operators manual Qualified personnel must be trained and certified in accordance with local laws and regulations WARRANTY The Company warrants that the equipment manufacture...

Страница 4: ...s the minimum protection degree IP 42 Improper grounding can result in electrical shock and can cause severe injury or death This product must be connected to a grounded metallic permanent wiring syst...

Страница 5: ...re to leave sufficient clearance 20 inches 500 mm around the dryer in order to allow an adequate cooling of the machine and for maintenance and or control operations The incoming air must be free from...

Страница 6: ...tuation can happen when ambient temperature is low and there is no compressed air load Variable speed fan control A patented microprocessor allows to adjust dryer s cooling capacity by changing the fa...

Страница 7: ...ower before performing any operation on the machine 3 1 2 CONDENSATE DISCHARGE PARAMETERS PROGRAMMING Push the SET key for 10 seconds to enter the parameters configuration menu the display will show i...

Страница 8: ...sists call your local OMI distributor ESA The automatic Energy saving mode activated due to low load Alarm output OFF Refrig Compressor output OFF Fan output OFF Drain cycle standard No action necessa...

Страница 9: ...dryer Otherwise wait 10 minutes before switching the dryer on again in order to allow freon pressure to rebalance 4 MAINTENANCE TROUBLESHOOTING AND DECOMMISSIONING 4 1 MAINTENANCE Before attempting a...

Страница 10: ...he electronic control board if the trouble persists replace them Activation of compressor s internal thermal protection Wait one hour and check again If the fault persists stop dryer and call your loc...

Страница 11: ...olenoid valve jammed clean or replace it Verify the condensate drainage times set on the electronic control board C8 and C9 Check the signal from the control board if it is continuous replace the cont...

Страница 12: ...ion n effectuer aucune op ration d entretien sur cette machine sans avoir coup l alimentation lectrique avoir purg compl tement l air sous pression et consult le manuel des op rateurs Le personnel qua...

Страница 13: ...ion des prestations du s choir point de ros e lev mais ne nuit pas la s curit Le circuit lectrique annexe B a un degr de protection minimum IP 42 Merci de noter que une mise terre incorrecte peut prov...

Страница 14: ...r le syst me de commande du ventilateur Garantir suffisamment d espace libre autour du s choir 20 inches 500 mm pour permettre le refroidissement correct de la machine et pour les op rations d entreti...

Страница 15: ...qu il n y a pas de traitement d air comprim Commande de variation de vitesse du ventilateur Un microprocesseur brevet permet d ajuster la capacit de refroidissement du s cheur en variant la vitesse du...

Страница 16: ...utes les 0 1 secondes ON OFF Appuyer sur la touche pendant 1 seconde active ou d sactive le processus Lorsque le processus est d sactiv l afficheur affiche le message OFF ATTENTION lorsque la carte le...

Страница 17: ...de la centrale Contacter le votre revendeur OMI local autoris ESA Option d conomie d nergie active Sortie alarme active Sortie compresseur inactive Sortie ventilateur inactive Sortie vacuation standar...

Страница 18: ...PANNES ET DEMANTELEMENT 4 1 ENTRETIEN Avant d effectuer toute op ration d entretien s assurer que 1 L installation n a pas de parties sous pression 2 L installation n a pas de parties sous tension UN...

Страница 19: ...avec la carte de commande lectronique V rifiez le c blage et la carte de commande lectronique remplacez les si le probl me persiste Activation de la protection thermique interne du compresseur Attend...

Страница 20: ...ation de la condensation lectrovanne d vacuation bloqu e Nettoyez la ou remplacez la V rifiez les temps d vacuation de la condensation r gl s sur la carte de commande lectronique C8 et C9 V rifiez le...

Страница 21: ...2 Fuses Fusibles FD Air filter 10 micron Filtre air 10 micron FF Filter dryer Filtre d shydrateur FH Air filter 0 01 micron Filtre air 0 01 micron FP Air filter 1 micron Filtre air 1 micron FQ Air fil...

Страница 22: ...dels ED18 to ED180 Cod 713 0057 06 00 Rev 00 Models ED270 to ED360 Condensate drain Purge de condensant Refrigerant line Ligne r frig rant Air inlet Entr e de l air Compressed air line Ligne de l air...

Страница 23: ...Cod 710 0138 62 00 Rev00 03 2016 22 30 B WIRING DIAGRAM SCHEMA LECTRIQUE Cod 714 0164 01 00 Rev 00 Models ED18 to ED72 115V 1Ph 60Hz Cod 714 0165 01 00 Rev 00 Models ED108 to ED180 115V 1Ph 60Hz...

Страница 24: ...Cod 710 0138 62 00 Rev00 03 2016 23 30 Cod 714 0168 03 00 Rev 00 Models ED270 to ED360 230V 1Ph 60Hz...

Страница 25: ...N NPT 3 8 3 8 1 1 AIR T F 100 C 38 AIR T MAX F 140 C 60 AMB T F 100 C 38 AMB T MIN MAX F 36 122 C 2 50 AIR W PRESS psi 100 bar 7 AIR PRESS MAX psi 203 174 bar 14 12 DEW POINT F 44 6 ISO CLASS 5 C 7 IS...

Страница 26: ...Temp entr e d air DISCH PRESS Discharge Pressure Pression de d charge AIR T MAX Max air inlet temperature Temp entr e d air max HP SWITCH SETTING High pressure switch setting R glage du pressostat de...

Страница 27: ...16 2 13 1 16 15 16 Power supply Alimentation Air flow Circulation de l air Models ED54 to ED180 A B C D E F G H L ED54 to ED72 mm 390 432 441 100 85 65 45 65 12 1 2 NPT 1 2 NPT 6mm 115 1 60 V ph Hz i...

Страница 28: ...30 Models ED270 to ED360 A B C D E F G H mm 500 679 980 157 254 99 5 114 40 1 1 2 NPT 1 1 2 NPT 6mm 230 1 60 V ph Hz inches 19 11 16 26 3 4 38 9 16 6 3 16 10 3 15 16 4 1 2 1 9 16 Power supply Aliment...

Страница 29: ...093 00 245 0093 00 245 0093 00 245 0093 00 245 0093 00 245 0093 00 1S1 Main power switch 250 0003 00 250 0003 00 250 0003 00 1V1 Complete solenoid drain valve 240 0106 00 240 0106 00 240 0106 00 240 0...

Страница 30: ...0093 00 245 0093 00 1S1 Main power switch 250 0015 00 250 0015 00 1V1 Complete solenoid drain valve 240 0108 00 240 0108 00 1B1 Drain solenoid valve coil 240 0102 00 240 0102 00 CND Condenser 921 0069...

Страница 31: ......

Отзывы: