4.10. FINAL TESTING
The static and dynamic load test with overloads are performed at the Manufacturer’s premises
The user may perform nominal load test (with ± 10% tolerance admitted for maximum valve calibration)
with distribution of the loads as described in the Loading conditions paragraph of the installations, use and
maintenance manual.
Test can be carried out with the following “overloading factors”
With loading distributed according the foreseen scheme of the machine of the machine in the chapter
“Loading conditions”
STATIC TEST
overload
150%
DYNAMIC TEST
overload
115%