manualshive.com logo in svg
background image

User’s Guide

omega.com  

e-mail: [email protected]

For Latest Product Manuals

omegamanual.info

®

®

Shop on line at

Wireless-to-Ethernet Receiver 

UWTC-REC3

Содержание UWTC-REC3

Страница 1: ...User sGuide omega com e mail info omega com For Latest Product Manuals omegamanual info Shop on line at Wireless to Ethernet Receiver UWTC REC3...

Страница 2: ...is document is believed to be correct but OMEGA Engineering Inc accepts no liability for any errors it contains and reserves the right to alter specifications without notice WARNING These products are...

Страница 3: ...a new IP Address over the Network 14 4 3 Receiver s Configurations and Operations 15 4 3 1 Power Up Device 16 4 3 2 Get Readings from the Connector Transmitter 17 4 3 3 Java Runtime Environment Setup...

Страница 4: ...Antenna 45 Part 6 Specifications 46 Part 7 Factory Preset Values 49 Appendix A Glossary 50 Appendix B IP Address 51 Appendix C IP Netmask 52 Appendix D ASCII Chart 53 ASCII Chart Control Codes 54 Appe...

Страница 5: ...igure 4 9 Comma Separated Value Format 18 Figure 4 10 Java 1 4 2 x Screen Shot 20 Figure 4 11 Java 1 5 x x Screen Shot 22 Figure 4 12 Java Policy 23 Figure 4 13 Java Policy 24 Figure 4 14 Select Chart...

Страница 6: ...important to successfully setup and use the Wireless System CAUTION or WARNING Tells you about the risk of electrical shock CAUTION WARNING or IMPORTANT Tells you of circumstances or practices that ca...

Страница 7: ...ides Web based monitoring of Temperature and Humidity Each Receiver can directly support up to thirty two 32 Thermocouples RTD Infrared and Humidity wireless Connectors Transmitters The Receiver allow...

Страница 8: ...the full span 40 to 125 C and 0 to 100 RH or within any narrow range such as 20 to 30 C The OPC Server software makes it easy to integrate the Receiver with many popular Data Acquisition and Automatio...

Страница 9: ...CB is mounted 7 4 position DIP switch sets the DHCP and Factory Defaults 8 Receiver s radio module firmware revision on label 9 Label with default IP address remove and then write your IP address in t...

Страница 10: ...holes Once the bracket is mounted to the wall align back of unit over the three bracket clips when engaged slide downward the unit will snap in place Version A Metal Enclosure Version B New Plastic E...

Страница 11: ...ON position 2 Power the Receiver on and wait about 10 seconds until the Receiver fully boots up 3 Set the DIP switch 2 back to OFF position it does not matter if the Receiver is powered ON or OFF jus...

Страница 12: ...inout 2 4 2 10Base T Crossover Wiring When connecting the Receiver directly to the computer the transmit data pins of the computer should be wired to the receive data pins of the Receiver and vice ver...

Страница 13: ...rotocols 3 3 DHCP DHCP Dynamic Host Configuration Protocol enables computers and devices to extract their IP configurations from a server DHCP server If DHCP is enabled on your Receiver as soon as the...

Страница 14: ...ery active device connected to the TCP IP network must have a unique IP address This IP address is used to establish a connection to the Receiver Every computer using TCP IP should have a unique 32 bi...

Страница 15: ...168 1 1 as shown below and press OK Figure 3 3 Network Connections 10 10 Look for Internet Protocol click on it and press Properties You can access the Receiver s web server via any internet browser u...

Страница 16: ...not the preferred method you can configure your PC s network connection with an IP address of 192 168 1 x that is in the same range as the Receiver s default IP address 192 168 1 200 and connect to th...

Страница 17: ...partment for obtaining an IP address Figure 4 2 Assigning an IP Address using iConnect 1 Place the IP address in this box 2 Take the MAC address from the label attached to the bottom of the Receiver a...

Страница 18: ...tinued d To access the Wireless System for Configuration Click on the View Webpage button you will access the Wireless System home page refer to Section 4 3 for details Figure 4 3 Accessing the Wirele...

Страница 19: ...e Wireless System Home Page Select button you ll be asked for the password You should be on the Access Control page were you can simply type in the desired Static IP address and click Save For more de...

Страница 20: ...IN and ADMINISTRATOR Passwords There are 2 different access levels 1 ADMINISTRATOR Password administrator allows certain groups and individual users to access and modify entire parameters without any...

Страница 21: ...il it can establish the connection back with the Receiver For a list of battery life versus the transmit time please refer to the UWTC Connector Transmitter manual Section 6 11 Once the Connector Tran...

Страница 22: ...ng page will appear Select the proper Group to view the readings Figure 4 7 Select Readings by Groups In a few seconds the following page will appear showing updates of the Process and Ambient Tempera...

Страница 23: ...remented for each newly received data Therefore it indicates if the sensor is transmitting data successfully This area also will display error messages Lost Receiver has not received data from the Con...

Страница 24: ...applet you have to enable the web browser and disable cache 4 3 3 1 Java Runtime Environment 1 4 Setup instructions 1 Go to your computer s Control Panel Open the Java Plug in 2 Select the Cache Tab...

Страница 25: ...below You should either select the Use Browser Settings option or the Direct Connection option depending on the network connections between your computer and the Receiver Generally select Direct Conn...

Страница 26: ...ions dialog and make sure that the Proxy tab shows that the Use Browser Settings option is not selected i e when you specify proxy connections in the Java Plugin control panel Accessing Receiver units...

Страница 27: ...shown in the file needs to be changed otherwise it will not work If more than one Receiver is being monitored from the same computer it is necessary to repeat the above for each of the Receivers in t...

Страница 28: ...ta Logging and Save Current Graph buttons in the Readings Charts and Diagnostic pages will not be active if the instructions explained in the above Section 4 3 4 are not followed Java Runtime Settings...

Страница 29: ...a Runtime Environment you may download it from our website or contact the Customer Service Department nearest you Figure 4 15 Chart UWTC RECEIVER Main Menu CHART 5 Seconds Div 1 Minute 1 Minute 1 Day...

Страница 30: ...icked once it turns bold highlights the process sensor trend line and displays current sensor readings When clicked twice it turns white and the trend line will disappear When clicked again it comes b...

Страница 31: ...work traffic Any error message LOST OPEN will be shown here as well Radio Signal Strength 0 100 the higher the better The blue line and blue triangle roof connecting to the Receiver indicates the radi...

Страница 32: ...io Version Firmware version of the radio module also shown on model serial label Configuration CONFIGURATION CONFIGURATION http 192 168 1 200 Address Main Menu Name UWTC REC3 Radio Reset Temperature C...

Страница 33: ...The Sensor Setup Page is for configuring the Connector Transmitter parameters such as Name and Update Rate Sensor Setup SENSOR SETUP BY GROUPS SENSOR SETUP http 192 168 1 200 Address Main Menu Wirele...

Страница 34: ...a text field and can take up to 8 alphanumeric characters Updates Seconds How often a Connector Transmitter sends its data to the Receiver Units Type of data and the corresponding units Units of meas...

Страница 35: ...webpage Therefore changing Update will not change the actual sample rate stored on the Connector Transmitter For a more accurate success rate and lost packet information it is necessary to change the...

Страница 36: ...which requires an Administrator password The default Login password is 12345678 This password can be up to 16 alpha numeric case sensitive characters If there is no Login Password assigned blank box...

Страница 37: ...t for obtaining a gateway address Subnet Mask It s a 32 bit number that is used to determine which part of the IP address is the network portion and which part is the host portion The Receiver default...

Страница 38: ...TPget exe file is used to setup and read information from the Receiver This file will be automatically installed when you install the MailNotifier software available on our website and CD Notes on usi...

Страница 39: ...eceiver s MAC address 4 6 ARP Protocol ARP is the Internet layer protocol responsible for matching or obtaining the MAC hardware address that corresponds to a particular IP address The ARP command all...

Страница 40: ...168 1 96 Pinging 192 168 1 96 with 32 bytes of data Reply from 192 168 1 96 bytes 32 time 5ms TTL 32 Reply from 192 168 1 96 bytes 32 time 3ms TTL 32 Reply from 192 168 1 96 bytes 32 time 3ms TTL 32 R...

Страница 41: ...s 95 98 NT 2000 XP and Vista c If you have Excel 2007 or higher when installing iLog choose Custom installation option and on the next window check the box for Excel 2007 Apps and continue the install...

Страница 42: ...3 column iTHX W Dual Probe 1st probe 3 column 6 column iSE TC iSD TC 3 column 5 column iSE TH iSD TH 3 column 5 column iBTHX W iBTHX D 3 column 4 column iBTX M iBTX SD 2 column iPTX W 2 column iTCX 3...

Страница 43: ...isting email that supports the MAPI messaging interface If MS OutlookTM has been loaded the MAPI support should be available 4 8 1 Installation The Mail Notifier must be loaded on a computer running M...

Страница 44: ...05 The Mail Notifier will attempt to automatically identify whether the Outlook is a newer version A red bar appears under the Mail Notifier splash window to confirm that the detection of the 2002 or...

Страница 45: ...gh value or Low value Specify Email Interval This determines how many seconds each subsequential alarm notification will be sent Determine Monitor interval This establishes the interval or time resolu...

Страница 46: ...use it within the Mail Notifier environment T Mobile phone_number tmomail net Virgin Mobile phone_number vmobl com AT T phone_number txt att net Sprint phone_number messaging sprintpcs com Verizon pho...

Страница 47: ...l for this device specifies the specific antenna supplied with this device 5 1 General Deployment Guidelines 1 Position Receiver in a central location When multiple Connector Transmitters are in opera...

Страница 48: ...A large building may have few obstructions between nodes but large amount of metallic paneling that cause reflections b A small domestic installation may have numerous brick walls between nodes in in...

Страница 49: ...itter and Receiver Also if the antennas are mounted just barely off the ground or below the ceiling over half of the Fresnel zone ends up being obstructed resulting in significant reduction in range B...

Страница 50: ...l Reduction Wood Plaster Sheetrock Fiberglass Uncoated Glass w out Metal 0 to 10 Brick Pressboard 5 to 35 Reinforced Concrete 10 to 90 Metal Walls Metal Doors Elevators Metal Piping Metal Stair Cases...

Страница 51: ...pean Community and other countries applies An improper combination of power level can result in an EIRP above the allowed amount per regulations See Appendix H Data Rate Bit rate 250 Kp s Symbol rate...

Страница 52: ...See Appendix H This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept an...

Страница 53: ...AckAGING Version A Metal Enclosure Version B New Plastic Enclosure Figure 6 1 Dimensions of the Receiver 66 0 2 60 93 1 3 67 Ethernet Ethernet 90 3 3 56 23 6 0 93 27 4 1 08 61 6 2 42 108 4 3 108 4 3 4...

Страница 54: ...ost Name z and last 4 digits from the MAC address Login Password 12345678 Admin Password 00000000 DHCP Disabled Web Server Enabled TCP Connections 1 Port 2000 Network ID 13106 0x3332 Channel 12 Name U...

Страница 55: ...number When you re connected to the Internet from your computer a correspondence table relates your IP address to your computer s physical MAC address on the LAN Ping is a utility that tests the netw...

Страница 56: ...pport approximately 216 65 536 computers per network The IP addresses range in binary from 10000000 00000000 xxxxxxxx xxxxxxxx to 10111111 11111111 xxxxxxxx xxxxxxxx The IP addresses range in decimal...

Страница 57: ...Mask Dotted Notation Mask Binary Mask Bits Class A 255 0 0 0 Default 0 255 192 0 0 2 255 224 0 0 3 255 240 0 0 4 255 248 0 0 5 255 252 0 0 6 255 254 0 0 7 255 255 0 0 8 255 255 128 0 9 255 255 192 0...

Страница 58: ...01010010 DC3 19 13 00010011 S 83 53 01010011 DC4 20 14 00010100 T 84 54 01010100 NAK 21 15 00010101 U 85 55 01010101 SYN 22 16 00010110 V 86 56 01010110 ETB 23 17 00010111 W 87 57 01010111 CAN 24 18...

Страница 59: ...11 Crtl Q Data Control 1 XON SOH 01 01 Crtl A Start of DC2 18 12 Crtl R Data Control 2 Header STX 02 02 Crtl B Start of Text DC3 19 13 Crtl S Data Control 3 XOFF ETX 03 03 Crtl C End of Text DC4 20 1...

Страница 60: ...d 10007 Windows socket error Wrong IP or wrong Port number was used 10008 The Receiver failed to respond to a request Wrong IP or wrong Port number was used 10011 Response came empty No data was sent...

Страница 61: ...rent address of Connector Transmitter EQPG Group ID 00A 00D Get sleep period battery voltage signal Get sleep period of strength success network address and group B EQPG00B parent address of a group a...

Страница 62: ...r Transmitter is lost 1 means there has not been any data received from that particular Connector Transmitter for 1 minute or 4 times the update rate whichever is a longer time interval Based on the a...

Страница 63: ...tructive object is only temporary you will get the sensor readings once the path is open Q Nothing happens when I click on the Data Logging button what could be wrong A The Java policy file is not set...

Страница 64: ...java runtime argument in Java Setup Control Panel with the appropriate path to the policy file Close all web browser and re open the applet again See Java Setup Section Q Nothing is shown inside the D...

Страница 65: ...er Connect the equipment to an outlet on a circuit different from which the receiver is connected Consult dealer or an experienced radio TV technician The following alert sign indicates that there are...

Страница 66: ..._______________________ ______________________________________________________________________________ ______________________________________________________________________________ __________________...

Страница 67: ..._______________________ ______________________________________________________________________________ ______________________________________________________________________________ __________________...

Страница 68: ..._______________________ ______________________________________________________________________________ ______________________________________________________________________________ __________________...

Страница 69: ...ONS Equipment sold by OMEGA is not intended to be used nor shall it be used 1 as a Basic Component under 10 CFR 21 NRC used in or with any nuclear installation or activity or 2 in medical applications...

Страница 70: ...tors R Turbine Paddlewheel Systems R Totalizers Batch Controllers pH coNdUcTIVITY R pH Electrodes Testers Accessories R Benchtop Laboratory Meters R Controllers Calibrators Simulators Pumps R Industri...