Table 1.3:
IEMP060J3A-DCG160
specifications
Model name
IEMP060J3A
Power supply
1-phase, 220-240V, 50Hz
Cooling
Capacity
W
15500(4430~15500)
Input
(IDU+ODU)
W
6600(1340~6600)
Input(IDU)
W
180
EER
/
2.35
Heating
Capacity
W
17200(4720~17200)
Input(IDU+ODU)
W
5800(1120~5800)
Input(IDU)
W
180
COP
/
2.97
Fan motor
Model
YSK180-4P
Type
Ac motor
Brand
Welling
Speed (H/M/L)
r/min
1080/960/710
Coil
Number of rows
4
Tube pitch × row pitch
mm
21×13.37
Fin spacing
mm
1.5
Fin type
Arc shutter
Tube OD and type
mm
Ф7, Copper pipe with internal thread
Dimensions (L×H ×W)
mm
1030×378×53.48
Number of circuits
8
Airflow rate
m3/h
2000/1750/1300
External static pressure
Pa
50(0-100)
Sound pressure level
dB(A)
46/39/36
Unit
Net dimensions (W×H×D)
mm
1200×300×800
Packed dimensions (W×H×D)
mm
1400×375×925
Net/Gross weight
kg
46.5/54(48/55.5)
4
Refrigerant type
R410A
Design pressure (H/L)
MPa
4.4/2.6
Pipe
connections
Liquid/Gas pipe
mm
Ф9.5/Ф15.9
Drain pipe
mm
Ф25
Piping Length
m
50
Level Difference
m
25
Controller
WDC-86E/K
Note:
1. The design implementation standard of this unit is GB/T 18836-2017.
2. The parameters in the table are the nominal values tested under the rated working conditions specified in GB/T 18836-2017, and
actual operating parameters will vary with the working conditions.
3. The above parameters may change due to product improvement. Please refer to the nameplate parameters of the product.
Содержание OTEC IEMP-D Series
Страница 1: ...IEMP D Series Ducted Fan Coil Technical Manual...
Страница 4: ...2 Part 1 General information 1 Model Names of Indoor Outdoor Units 3 2 External Appearance 4...
Страница 17: ...17 ICHD031J0A DMG090...
Страница 18: ...18 ICHD036J0A DMG105 ICHD042J0A DMG120 ICHD048J0A DMG140...
Страница 19: ...19 ICHD060J0A DMG160...
Страница 29: ...36 IEMP031J3A DCG090 IEMP060J3A DCG160...
Страница 30: ...37 IEMP036J3A DCG105 IEMP042J3A DCG120 IEMP048J3A DCG140...
Страница 86: ...126 IEMP031 36 42 48 60 J3A DCG090 105 120 140 160...