manualshive.com logo in svg
background image

The system may be "Disarmed" by any of 2 methods:

1) 

Remote Control Disarming:   Press & Release the “Disarm” button

Upon Disarm: • The siren will chirp twice. 

(4 chirps if alarm has activated & reset)

• The parking lights will flash twice. 

(4 times if alarm has activated)

• The starter interrupt will disengage.
• The LED Status Indicator turns off

Disarming the Alarm

2)  Emergency Override:

   THEN WITHIN
   10 SECONDS

Page 3

 Step 1:

With the system in the armed condition use your key, turn the

  ignition to the "On" position.

 Step 2:

Within 10 seconds, Press & Release the Valet/  Override Switch.

System  Armed & Activated

Regardless of the method used to Arm the alarm, once Armed, the alarm will
monitor all protected zones, and if an intrusion attempt is detected it will activate,
or “trigger”.

A trigger consists of the following:

• The electronic siren will start sounding.
• The parking lights will flash on and off repeatedly.

An activation has a 30 second duration unless the system is disarmed using the
remote control or the Valet /Override switch. If all protected zones are secure at
the end of the trigger, the system will stop and rearm itself to detect further entry
attempts. If a protected zone is still open at the end of the trigger cycle, the alarm
will continue to re-trigger itself for up to six activated cycles before it resets itself
and ignores the violated zone.

Содержание MC-1

Страница 1: ...MC 1 Motocycle Personal Craft Security System Operation and Installation Guide c 2009 Omega Research Development Inc...

Страница 2: ...his device must accept any interference received includinginterferencethatmaycauseundesiredoperation The manufacturer is not responsible for any radio or TV interferencecausedbyunauthorizedmodificatio...

Страница 3: ...ights will flash once The LED Status Indicator will begin to flash slowly The starter interrupt will engage The alarm is now fully armed Once it is disarmed it will not automatically arm again This fe...

Страница 4: ...med Activated Regardless of the method used to Arm the alarm once Armed the alarm will monitor all protected zones and if an intrusion attempt is detected it will activate or trigger A trigger consist...

Страница 5: ...ivated if the vehicle s ignition is On ThissecuritysystemisequippedwithadualstageDigitalTiltSensortoincrease it seffectiveness Eachtimethealarmisarmed thetiltsensorentersa5second learning period in wh...

Страница 6: ...s The siren will emit a 2 long chirps to endicate it has exited the sensitivity adjustment mode The parking lights will flash twice Or the horn will sound if connected TheLEDStatusIndicatorvisuallysho...

Страница 7: ...n use Valet Mode can only be entered into while the alarm is Disarmed ValetModeisdesignedforsituationsinwhichitisnotconvenientfortheautomatic armingandautomaticrearmingportionofthealarmtobeoperational...

Страница 8: ...med at the same time How to Program Features To access Features Programming Mode Step 1 Turn the ignition On then Off Step 2 Within 10 seconds of turning the ignition Off press the Valet Switch 5 time...

Страница 9: ...en arming and disarming Pressingthe Arm buttonmakesthesirendurationsettoMedium pressingthe Disarm buttonmakesthesirendurationsettotheLowestsetting andpressing the button extends the time to the Highes...

Страница 10: ...these is the case In either case the included fuse holder and a 15 amp fuse must be used The fuse holders should always be close to the power source connection not the control module Remove the 15 amp...

Страница 11: ...rm is triggered SIREN CONNECTION The Brown wire may be connected directly to the siren s Red wire and the siren s Black wire is connected to Ground SIRENMOUNTING Findalocationawayfromtheextremeheatoft...

Страница 12: ...tional output operated by the remotes button CONNECTION If the target wire is Positive switching and or draws more than 250mA an optional relay must be used To configure a relay to the Pink wire conne...

Страница 13: ...Page 12...

Отзывы: