7. Auxiliary Ouput: ( •On Demand = 1 siren chirp / Latched = 2 chirps /
Remote Start = 3 chirps)
- This feature allows the user to change the setting for the Auxillary Output wire.
- Pressing the “Arm” button turns the feature On Demand, pressing the “Disarm”
button turns the feature to Latched, and pressing the “••” button turns the Remote
Start feature on. The Remote Start feature off the Digital Tilt Sensor, ignition input,
and disable the starter kill before it activates.

Programmable  Features (Continued)

6 Pin Connector:

Red Wire -  (Constant Power Input):  The Red  wire supplies constant Positive
12 Volts for the system's operation.

CONNECTION:  Connect this wire to a Positive battery voltage; both wires

must be connected.  One source is the battery's Positive terminal, and another
potential source is the power supply wires at the ignition switch.

If the battery is selected as the power source, and the Red wire must

extended, the added wire must be at least the same gauge, or preferably
heavier, than the Red  wire.

Some vehicles have a Constant 12 Volt circuit supplying the ignition switch,

while others have multiple supply circuits.  A schematic of the vehicles
electrical system will show which of these is the case.

In either case, the included fuse holder and a 15 amp fuse must be used.

The fuse holders should always be close to the power source connection, not
the control module.  Remove the 15 amp fuse before making the holders’
connection, and only reinsert it after all of the other wiring connections have
been made.  Caution! The use of  the 15 amp fuse and the fuse holder are
required!  Failure to properly install the fuse holder and the 15 amp fuse
will void all warranties.

20ga Black Wire -  (Ground):  The Black wire provides Negative ground for the
system; proper connection of this wire is very important.

CONNECTION: Using the correctly sized crimp-on ring terminal, connect

the Black wire to the metal frame of the vehicle, preferably using an existing
machine-threaded fastener.  Make sure that the ring terminal attached to the
Black wire has contact with bright, clean metal.  If necessary, scrape any paint,
rust or grease away from the connection point until the metal is bright and clean.
If the control module has an insufficient ground connection, the security system
can find partial ground through the wires that are  connected to other circuits,
and function, but not correctly.  As the system can partially operate, a bad
ground wire connection would not likely be suspected, and in many cases a
poor ground is difficult to diagnose.

Wiring Description

Содержание MC-1

Страница 1: ...MC 1 Motocycle Personal Craft Security System Operation and Installation Guide c 2009 Omega Research Development Inc...

Страница 2: ...his device must accept any interference received includinginterferencethatmaycauseundesiredoperation The manufacturer is not responsible for any radio or TV interferencecausedbyunauthorizedmodificatio...

Страница 3: ...ights will flash once The LED Status Indicator will begin to flash slowly The starter interrupt will engage The alarm is now fully armed Once it is disarmed it will not automatically arm again This fe...

Страница 4: ...med Activated Regardless of the method used to Arm the alarm once Armed the alarm will monitor all protected zones and if an intrusion attempt is detected it will activate or trigger A trigger consist...

Страница 5: ...ivated if the vehicle s ignition is On ThissecuritysystemisequippedwithadualstageDigitalTiltSensortoincrease it seffectiveness Eachtimethealarmisarmed thetiltsensorentersa5second learning period in wh...

Страница 6: ...s The siren will emit a 2 long chirps to endicate it has exited the sensitivity adjustment mode The parking lights will flash twice Or the horn will sound if connected TheLEDStatusIndicatorvisuallysho...

Страница 7: ...n use Valet Mode can only be entered into while the alarm is Disarmed ValetModeisdesignedforsituationsinwhichitisnotconvenientfortheautomatic armingandautomaticrearmingportionofthealarmtobeoperational...

Страница 8: ...med at the same time How to Program Features To access Features Programming Mode Step 1 Turn the ignition On then Off Step 2 Within 10 seconds of turning the ignition Off press the Valet Switch 5 time...

Страница 9: ...en arming and disarming Pressingthe Arm buttonmakesthesirendurationsettoMedium pressingthe Disarm buttonmakesthesirendurationsettotheLowestsetting andpressing the button extends the time to the Highes...

Страница 10: ...these is the case In either case the included fuse holder and a 15 amp fuse must be used The fuse holders should always be close to the power source connection not the control module Remove the 15 amp...

Страница 11: ...rm is triggered SIREN CONNECTION The Brown wire may be connected directly to the siren s Red wire and the siren s Black wire is connected to Ground SIRENMOUNTING Findalocationawayfromtheextremeheatoft...

Страница 12: ...tional output operated by the remotes button CONNECTION If the target wire is Positive switching and or draws more than 250mA an optional relay must be used To configure a relay to the Pink wire conne...

Страница 13: ...Page 12...

Отзывы: