Page 9
7. Auxiliary Ouput: ( •On Demand = 1 siren chirp / Latched = 2 chirps /
Remote Start = 3 chirps)
- This feature allows the user to change the setting for the Auxillary Output wire.
- Pressing the “Arm” button turns the feature On Demand, pressing the “Disarm”
button turns the feature to Latched, and pressing the “••” button turns the Remote
Start feature on. The Remote Start feature off the Digital Tilt Sensor, ignition input,
and disable the starter kill before it activates.
Programmable Features (Continued)
6 Pin Connector:
Red Wire - (Constant Power Input): The Red wire supplies constant Positive
12 Volts for the system's operation.
CONNECTION: Connect this wire to a Positive battery voltage; both wires
must be connected. One source is the battery's Positive terminal, and another
potential source is the power supply wires at the ignition switch.
If the battery is selected as the power source, and the Red wire must
extended, the added wire must be at least the same gauge, or preferably
heavier, than the Red wire.
Some vehicles have a Constant 12 Volt circuit supplying the ignition switch,
while others have multiple supply circuits. A schematic of the vehicles
electrical system will show which of these is the case.
In either case, the included fuse holder and a 15 amp fuse must be used.
The fuse holders should always be close to the power source connection, not
the control module. Remove the 15 amp fuse before making the holders’
connection, and only reinsert it after all of the other wiring connections have
been made. Caution! The use of the 15 amp fuse and the fuse holder are
required! Failure to properly install the fuse holder and the 15 amp fuse
will void all warranties.
20ga Black Wire - (Ground): The Black wire provides Negative ground for the
system; proper connection of this wire is very important.
CONNECTION: Using the correctly sized crimp-on ring terminal, connect
the Black wire to the metal frame of the vehicle, preferably using an existing
machine-threaded fastener. Make sure that the ring terminal attached to the
Black wire has contact with bright, clean metal. If necessary, scrape any paint,
rust or grease away from the connection point until the metal is bright and clean.
If the control module has an insufficient ground connection, the security system
can find partial ground through the wires that are connected to other circuits,
and function, but not correctly. As the system can partially operate, a bad
ground wire connection would not likely be suspected, and in many cases a
poor ground is difficult to diagnose.