2
9. Install the back coverplate. Make sure
the O-ring is securely seated and no
wires are pinched.
10. Connect to the user interface device ac-
cording to manufacturer’s instructions.
11. Refer to the etched K-factor on the tur-
bine. See Turbine Manual for location
of K-factor.
NOTE: Please remember to supply a 820
ohm (minimum) Pull Up Resistor if the
interface device does not have one. Ref-
erence illustration above as necessary.
Frequency Range: 0 to 750 Hz
Housing Material: Nylon 6/6
Strain Relief:
Hubble-PG7
Coverplate Thread: Female 1/2-20 UNF-2B
Cable:
Belden 9363
Std. Cable Length: 10 ft. (3m)
Temperature:
+14
°
to +140
°
F
(–10
°
to +60
°
C)
Open Collector
Currect Sinking Output
Applied Voltage:
0 to 60 Volts DC
Connection:
Two Wire
Allowable Current: Up to 100 mA
Output:
Square Wave Pulse.
Amplitude same as
supplied voltage.
NOTE: Display electronics, which work in
conjunction with this module, continue
to be powered with batteries.
TECHNICAL SPECIFICATIONS
The Pulse Output Module with a standard FTB790
Series Turbine Meter with Display Electronics
which are sold seperately.
Dimensions (FLSC790-P)
0.25 in. (.64 cm)
0.8 in.
(2.0 cm)
➤
➤
➤
➤
3.25 in. (8.26 cm)
➤
➤
1.63 in.
(4.14 cm)
➤
➤
1.0 in.
(2.54 cm)
➤
➤
2.0 in.
(5.1 cm)
➤
➤
Содержание FLSC790-P
Страница 6: ...4 NOTES...