pg. 13 of 33
e)
Electrical Connections – Current Output Units (“I” Suffix)
The FLR 1000–ST-I provides a 4-20mA active current output proportional
to the flow rate.
The cable assembly should be connected to the sensor as detailed in
section 5(b) above. Power should not be applied to the sensor until all the
connections have been made and checked. Electrical connections should
be made as follows:
Wiring Schematic For Current Ouput Units (“I” suffix only).
The
RED
wire should be connected to the Positive of the power source.
The
BLACK
wire should be connected to the Negative ( Ground ) of the
power source.
The
WHITE
wire provides the signal output (active current) and should be
connected to the positive terminal of the display, data acquisition system
or current meter with an impedance of 0 - 500
Ω
(Ohms).
The
GREEN
wire is NOT used.
Caution: Avoid high voltage static discharges to any of the
connections. Do not short the input/output signal wires or allow
them to contact the power wires at any time. DAMAGE WILL
RESULT!
Содержание FLR 1000
Страница 1: ...FLR 1000 1000BR 1000ST Series Flow Sensors Meters For Liquids...
Страница 2: ......
Страница 25: ...pg 25 of 33 FLR 1000 BR FLR 1000 ST For Liquids 1 4 Compression Fittings Shown...
Страница 26: ...pg 26 of 33 FLR 1000 ST I For Liquids 1 4 Fittings Shown...
Страница 27: ...pg 27 of 33 FLR 1000 D For Liquids 1 4 Acetal Fittings Shown...
Страница 28: ...pg 28 of 33 FLR 1000 BR D FLR 1000 ST D For Liquids 1 4 Compression Fittings Shown...
Страница 32: ...pg 32 of 33...
Страница 33: ...M4574 0807 pg 33 of 33...