15

  6.   To program minimum graph percentage, 

the  display will indicate 0 0 with the right 
digit flashing, the bottom most segment 
of the bar graph will flash, and the 
display will read “PCTFS” (percent full 
scale).   Press 

U

C

U

D

  

  to scroll to a 

num-ber 0-9. Press  

U

u

|

|

    

  to select that 

num-ber.  The left digit will now begin to 
flash.  Press 

U

C

U

D

  

.  to scroll to a  

number 0-9.  

U

u

|

|

     

.  to select that 

number.  The 2 digit number entered 
represents the percentage of full scale 
to be used as the low end of the graph 
(0-99%).

  7.   To program maximum percentage of full 

scale the display will indicate 1 0 0 with 
the right digit flashing, the upper most 
segment of the graph will flash, and 
the display will read PCTFS (percent full 
scale). Press 

U

C

U

D

 

.  to scroll to  

a number 0-9. Press  

U

u

|

|

    

   to select 

that number.  The left 2 digits will now 
begin to flash. Press 

U

C

U

D

 

 to  

scroll to a number 0-10. Press  

U

u

|

|

  

  

to select that number.  The number 
entered represents the percentage of full 
scale to be used as the high end of the 
graph.  Note: 100 is the highest and only 
possible 3 digit number.  If the low num-
ber is equal to or larger than the high 
number, the unit will flash “REJCT”  
and it will exit back into the “GRAPH” 
sub-menu.

 

 Note:

 Custom graph function is not available 

on vacuum and compound ranges.

 

 Note:

 A display message “ULOCK” indicates 

that custom units are being used and bar 
graph minimum and maximum are set to 
the factory defaults

Reset: 

Returns the product to the factory default val-
ues.Preserves field calibration. Factory calibra-
tion can be restored in the “RECAL” menu. 
  1.   In menu mode 

U

C

U

D

 

 until 

“RESET” appears on display’s lower 
line.

  2.  Press  

U

u

|

|

    

.

  3. Press 

U

C

U

➟ 

to scroll CNFRM  

   

(confirm) or CANCEL (cancel).

  4.  Press  

U

u

|

|

    

➟ 

to select.

   

Factory defaults pertain to units, timer,    

   

back light, update rate, zero lock.

   

 Display will indicate “DONE” then gauge 
will switch to “OFF”  condition. 

Содержание DPG8001

Страница 1: ...1 omega com e mail info omega com For latest product manuals omegamanual info DPG8001 M 5103 0217 General Purpose Digital Pressure Gauge Shop online at User sGuide ...

Страница 2: ...2 ...

Страница 3: ... specifications without notice omega com info omega com Servicing North America U S A Omega Engineering Inc Headquarters Toll Free 1 800 826 6342 USA Canada only Customer Service 1 800 622 2378 USA Canada only Engineering Service 1 800 872 9436 USA Canada only Tel 203 359 1660 Fax 203 359 7700 e mail info omega com For Other Locations Visit omega com worldwide ...

Страница 4: ...4 ...

Страница 5: ...lastic housing can cause permanent damage to the product m m WARNING READ BEFORE INSTALLATION 1 GENERAL A failure resulting in injury or damage may be caused by excessive overpressure excessive vibration or pressure pulsation excessive instrument temperature corrosion of the pressure containing parts or other misuse Consult Omega Engineering before installing if there are any questions or concerns...

Страница 6: ...er U u b Zero Up Arrow Tare U ZERO CTare c Menu Selection Down Backlight Arrow U MENU D d Key presses are short less than 0 5 seconds or long greater than 0 5 seconds Note Key presses designated as short less than 0 5 sec are indicated by ICON a b d c ...

Страница 7: ...ressure display b 20 segment pressure range bar graph each segment equals 5 of range c Sleep and Backlight Timer symbols d Maximum Minimum Pressure and Tare icons e 5 character alpha numeric digit display f 4 segment battery life indicator 7 Negative pressure indicator ...

Страница 8: ...cally to the Measure ment Mode Zero Function Press U ZERO Upon release the numeric display momentarily disappears and ZERO shows in alpha display then returns to mea surement mode The pressure should now read 0 Zero value is stored in memory Note 1 A display message of RLOCK indi cates that zero is more than 5 from factory calibration Zeroing is not possible Note 2 A message of ZLOCK indicates tha...

Страница 9: ...d to programming mode 2 Press U C U D to scroll through pro grammable menu options 3 When desired option is reached press U u to access that parameter 4 If at any time you choose to EXIT the menu mode or sub menu mode hold U MENU Your work will not be saved Programmable Parameters Units of Measure 1 In Menu mode press U C U D to scroll to UNITS press U u 2 Choose engineering units by scrolling U C...

Страница 10: ...t remains at the location chosen in step 1 Press U C U D to change the value of the digit between 0 9 Once the desired value is displayed press the U u button to lock it in place Now the next digit to the right will begin blinking Repeat this procedure for all 5 digits When the U u is pressed and released with the fifth digit flashing the gauge will briefly display DONE then return to measurement ...

Страница 11: ...ts when any key is pressed Light this is initiated upon powering the unit or since the values were cleared 1 When in menu mode press U C U D to scroll to Max maximum display this is indicated in small font to the left of the display s unit of measure 2 To clear both Min and Max values press and hold U ZERO 3 Release of this key will leave you in Menu mode Use U C U D to continue scrolling through ...

Страница 12: ...ode Note In PRESS mode factory has set 1 hour timer to save battery Feature Back light indicator will blink 10 sec onds prior to light shut off Update Utilized to select the rate at which the displayed pressure value is updated on the screen This function is used when rapid changes in pressure cause flutter in the display values longer intervals will reduce the update rate and average the readings...

Страница 13: ...will restore values of factory calibration 4 Pressing U u when FIELD is dis played will restore values from latest field calibration 5 Pressing Enter key U u when NEW appears will enter the recalibrate mode 6 When NEW is displayed press U u upon release display will flash CNFRM or CANCEL press U C or U D to select then press Enter key U u then the dis play will flash CNFRM press ENTER OK APPLY REF...

Страница 14: ... are within 7 If outside this window the display will indicate CAL FAIL INPUT PRES TOO LOW HIGH PRESS ENTERTORETRY PRESSOTHERTOABORT Note FIELD option appears only if gauge has been successfully field recalibrated Graph Provides the user the ability to modify pressure values dictating the minimum maximum indi cations over the 20 segment bar graph 1 In menu mode press U C U D until GRAPH appears pr...

Страница 15: ...h Press U C U D to scroll to a number 0 10 Press U u to select that number The number entered represents the percentage of full scale to be used as the high end of the graph Note 100 is the highest and only possible 3 digit number If the low num ber is equal to or larger than the high number the unit will flash REJCT and it will exit back into the GRAPH sub menu Note Custom graph function is not a...

Страница 16: ...ries are in the proper polarity position For reattachment of cover align the unlock icon with the arrow push cover straight in then turn clockwise until the arrow is in alignment with the Lock icon Note Reinstallation of the back cover may cause the unit to read negative pressure This is a temporary issue as the internal case pressure will be relieved by the case vent and equalize with atmospheric...

Страница 17: ...an 3000 5000 150 7500 25 000 120 Burst Pressure Vac 2000 800 of Span 3000 5000 500 7500 25 000 300 Environmental Specifications Temperature Storage Batteries removed 20 C to 80 C 4 F to 176 F Batteries installed 20 C to 60 C 4 F to 140 F Ambient Operating 20 C to 60 C 4 F to 140 F Process Media 20 C to 80 C 4 F to 176 F Agency Approvals CE Annex A Heavy Industrial UL cUL 61010 1FileE171189 Vol X1 ...

Страница 18: ...18 ...

Страница 19: ... by OMEGA if the unit is found to be defective it will be repaired or replaced at no charge OMEGA s WARRANTY does not apply to defects resulting from any action of the purchaser including but not limited to mishandling improper interfac ing operation outside of design limits improper repair or unauthorized modification This WARRANTY is VOID if the unit shows evidence of having been tampered with o...

Страница 20: ...ors M U Turbine Paddlewheel Systems M U Totalizers Batch Controllers pH CONDUCTIVITY M U pH Electrodes Testers Accessories M U Benchtop Laboratory Meters M U Controllers Calibrators Simulators Pumps M U Industrial pH Conductivity Equipment DATA ACQUISITION M U Communications Based Acquisition Systems M U Data Logging Systems M U Wireless Sensors Transmitters Receivers M U Signal Conditioners M U D...

Отзывы: