1. Power on Start: Program starts from the current PV value.
2. Output on END:
Output condition at the end of the program (rEnd)
3. Output on OFF:
Output condition when program is terminated (roFF)
4. Repeat function: Ramp-soak program operates repeatedly.
If the repeat function is off, the SV value on the last
step is maintained.
Stand-by mode:
Output -3%, Alarm off.
Going on Control:
When program ends (rEnd), control is at the SV value
on the last step. When program is terminated (roFF), control
is at the main SV value.
MOD Power on start Output on END
Output on OFF Repeat function
0
No
Continue controlling
Continue controlling
No
1
No
Continue controlling
Continue controlling
Yes
2
No
Continue controlling
Stand-by mode
No
3
No
Continue controlling
Stand-by mode
Yes
4
No
Stand-by mode
Continue controlling
No
5
No
Stand-by mode
Continue controlling
Yes
6
No
Stand-by mode
Stand-by mode
No
7
No
Stand-by mode
Stand-by mode
Yes
8
Yes
Continue controlling
Continue controlling
No
9
Yes
Continue controlling
Continue controlling
Yes
10
Yes
Continue controlling
Stand-by mode
No
11
Yes
Continue controlling
Stand-by mode
Yes
12
Yes
Stand-by mode
Continue controlling
No
13
Yes
Stand-by mode
Continue controlling
Yes
14
Yes
Stand-by mode
Stand-by mode
No
15
Yes
Stand-by mode
Stand-by mode
Yes
Table of Ramp/Soak Modes
Содержание CN4321
Страница 33: ...32 SYSTEM WIRING DIAGRAMS Example 1 Example 2...
Страница 45: ...44 Deadband Overlap...
Страница 48: ...47 Table of Input Type Codes...
Страница 50: ...49...
Страница 53: ...52 Table of Alarm Action Type Codes CN4321...
Страница 54: ...53 Table of Alarm Action Type Codes CN4431...
Страница 59: ...58 Table of Output Type Codes...