The OMEGA Family of Blackbody Calibrators

9

9-1

The OMEGA Family of Blackbody Calibrators

Listed below is a selection guide of OMEGA’s current line of blackbody calibration 

sources in addition to the one you have selected. This family of rugged, portable and 

accurate calibrators cover a wide range of temperatures, target plate sizes and features 

making them perfect for infrared pyrometer field service testing and laboratory 

calibrations. 

BB701 Hot/Cold Blackbody Calibration Source  

 

Calibration Range: -18 to 149°C (0 to 300°F) 

Accuracy: ±0.8°C (±1.4°F) 

Emissivity: 0.95  

Ambient Temp.: 4 to 43°C (40 to 110°F) 

Cavity Size: 63.5 mm (2.5 in.) 

Power: 115/230V, 50/60 Hz, 175W 

BB702 Blackbody Calibration Source 

 

Calibration Range: 32 to 215°C (amb. 90 to 420°F) 

Accuracy: ± 0.5°C (±0.9°F), ±0.25% rdg. 

Emissivity: 0.95 

Ambient Temp.: 5 to 45°C (41 to 113°F) 

Cavity Size: 63.5 mm (2.5 in.) 

Power: 115/230V, 50/60 Hz, 75W 

BB703 Mini Blackbody Calibration Source 

 

Calibration Range: 32 to 400°C (90 to 752°F) 

Accuracy: ±1.4°C (±2.5°F) 

Emissivity: 0.95 

Ambient Temp.: 0 to 40°C (32 to 104°F) 

Cavity Size: 28.6 mm (1.125 in.) 

Power: 115/230V, 50/60 Hz, 175W 

BB704 4” Target Plate Blackbody Calibration Source   

Calibration Range: 100 to 400°C (212 to 752°F) 

Accuracy: ±0.8°C (±1.4°F) 

Emissivity: 0.95  

Ambient Temp.: 0 to 50°C (32 to 122°F) 

Cavity Size: 101.6 mm (4 in.) 

Power: 115/230V, 50/60 Hz, 425W 

BB705 Laboratory Grade Blackbody Calibration Source   

Calibration Range: 100 to 1046°C (212 to 1915°F) 

Accuracy: ±1.0°C (±1.8°F), ±0.25% rgd   

Emissivity: 0.99 

Ambient Temp.: 0 to 35°C (32 to 95°F) 

Cavity Size: 44 mm (1.75 in.) 

Power: 115/230V, 50/60 Hz, 1100W 

BB-4A High Temperature Blackbody Calibration Source   

Calibration Range: 100 to 982°C (212 to 1800°F) 

Accuracy: ±1.0°C (±1.8°F), ±0.25% rdg 

Emissivity: 0.99 

Ambient Temp.: 0 to 50°C (32 to 122°F) 

Cavity Size: 22.2 mm (0.88 in.) 

Power: 115/230V, 50/60 Hz, 400W 

For a complete, updated specification sheet and price on any of the calibrators listed here visit our 

website at www.omega.com. Please call our sales or customer service department for information 

and pricing on any new models available.

Содержание BB700 Series

Страница 1: ...latest product manuals www omegamanual info BB705 Very High Temperature Laboratory Blackbody Calibration Source Shop online at omega com User sGuide TM This datasheet has been downloaded from http www...

Страница 2: ...pecifications without notice omega com info omega com Servicing North America U S A Omega Engineering Inc Headquarters Toll Free 1 800 826 6342 USA Canada only Customer Service 1 800 622 2378 USA Cana...

Страница 3: ...4 Controller Settings 3 5 3 4 1 Changing the Temperature Setpoint 3 5 3 4 2 Changing the Controller Parameter Settings 3 6 3 5 Temperature Reference Meter Settings 3 7 3 6 Target Cavity Temperature T...

Страница 4: ...e 3 3 5 Rear Panel 3 4 6 Controller Default Parameters 3 6 7 Controller Programming Procedures 3 7 8 Approximate Target Plate Temperature Transition Times 3 8 9 Connecting a PC to the BB705 s Controll...

Страница 5: ...t this unit to a non grounded non polarized outlet or power source This unit is intended for indoor use only Avoid exposure to any moisture or rain Do not connect the serial ports to equipment with ex...

Страница 6: ...The calibration source with built in PID digital controller maintains an accuracy of 0 25 of reading 1 C The cavity has a 44 5 mm 1 75 diameter aperture with an emissivity of 0 99 and can be set to a...

Страница 7: ...reshipment is necessary The following items are supplied in the box Item OMEGA Part Number BB705 Blackbody Calibration Source BB705 or BB705 230 User Manual M 3638 Calibration Certificate CAL 3 3 DATA...

Страница 8: ...0 VAC 50 60 Hz Models On 230 VAC 50 60Hz models an International style power cord with the proper color code and approvals is provided with stripped wire ends for connection to the proper connector us...

Страница 9: ...3 3 1 C A U T I O N CAVITY MAY B E H O T 1000C 1000 00C 1000C SETPTS MAX DEV MENU TEMPERATURE REFERENCE METER TEMPERATURE CONTROLLER SET VARIABLE PROCESS VARIABLE CAVITY APERTURE APERTURE PLATE POWER...

Страница 10: ...is used to set the setpoint temperature and change engineering units Temperature Reference Meter The temperature reference meter displays the cavity temperature with high precision See Section 3 5 for...

Страница 11: ...ronment only Never operate the unit outside or around children Nothing should come in contact with the heater cavity aperture or aperture plate Even when the unit is off Never unplug the unit while it...

Страница 12: ...E METER CAUTION FOR CONTINUED PROTECTION AGAINST THE RISK OF FIRE REPLACE WITH ONLY THE SAME TYPE RATING AND SIZE OF FUSE DISCONNECT POWER FROM SOURCE BEFORE CHANGING FUSE INSTALLATION CATEGORY II 208...

Страница 13: ...t temperature of the target plate Setpoint Temperature This field displays the desired target plate temperature Once the target plate reaches this desired temperature both displays will read the same...

Страница 14: ...hrough LED indicators An indicator may be lit continuously blink or shut off entirely to indicate that the process is on being pulsed or off respectively 3 4 2 Changing the Controller Parameter Settin...

Страница 15: ...ress the MENU key until the display reads RDG CNF 2 Press the MIN key until the display reads RDG 5 3 Set this parameter as desired using the MAX key 0 C 1 F 2 K 4 Press MENU to store the settings 5 P...

Страница 16: ...to another First determine the current heater cavity temperature and go to the corresponding row Now decide the new heater cavity temperature and go to the appropriate column Note that there are X s a...

Страница 17: ...ers should be viewed or queried from the controller directly It is highly recommended that baud rate for the controller be modified on the controller directly Note that both the BB705 and the computer...

Страница 18: ...case R To read a parameter from the controller M To temporarily modify a controller parameter lost upon shutdown E To modify a controller param in non volatile mem saved even after shutdown parameter...

Страница 19: ...ing soot from heater cavity be sure to wear protective goggles NEVER REMOVE SOOT FROM A HOT OR WARM CAVITY Be sure unit has cooled to room temperature and is disconnected from power source before vacu...

Страница 20: ...ontrol Sensor Platinum Thermocouples Accuracy 1 C 0 25 rdg 1 8 F 0 25 rdg Ref Meter Display Accuracy 0 06 C over entire range Resolution 0 01 on temperature reference meter Overall System Stability 0...

Страница 21: ...ler display shows Error a Unit requires service contact our and the target plate will not get customer service department hot or cold 4 Target plate temperature will a Verify that the controller is se...

Страница 22: ...e ratio of energy emitted by a surface to the energy emitted by a blackbody at the same temperature IEC International Electrotechnical Commission Infrared IR A range of the electromagnetic spectrum ex...

Страница 23: ...ource Calibration Range 32 to 400 C 90 to 752 F Accuracy 1 4 C 2 5 F Emissivity 0 95 Ambient Temp 0 to 40 C 32 to 104 F Cavity Size 28 6 mm 1 125 in Power 115 230V 50 60 Hz 175W BB704 4 Target Plate B...

Страница 24: ...NOTES BB705 Very High Temperature Laboratory Blackbody Calibration Source 9 2...

Страница 25: ...A if the unit is found to be defective it will be repaired or replaced at no charge OMEGA s WARRANTY does not apply to defects resulting from any action of the purchaser including but not limited to m...

Страница 26: ...s M U Turbine Paddlewheel Systems M U Totalizers Batch Controllers pH CONDUCTIVITY M U pH Electrodes Testers Accessories M U Benchtop Laboratory Meters M U Controllers Calibrators Simulators Pumps M U...

Отзывы: