M789-038A

15 June 1999

 

   

   

Содержание CYD201

Страница 1: ...M789 038A 15 June 1999...

Страница 2: ...nty and repair requests inquiries to the OMEGA Customer Service Department Call toll free in the USA and Canada 1 800 622 2378 FAX 203 359 7811 International 203 359 1660 FAX 203 359 7806 BEFORE RETUR...

Страница 3: ...2 1 2 3 Power and Ground Requirements 2 2 2 4 Sensor Installation Recommendations 2 2 2 4 1 Two Lead Vs Four Lead Measurements 2 3 2 4 2 Connecting Leads to the Sensor 2 4 2 4 3 Sensor Mounting 2 4 2...

Страница 4: ...face Command Summary 4 4 5 SERVICE 5 1 5 0 General 5 1 5 1 Model CYD201 Rear Panel Connections 5 1 5 2 Model CYD208 Rear Panel Connections 5 2 5 3 Error Code Troubleshooting 5 3 5 4 General Maintenanc...

Страница 5: ...J10 RJ 11 Cable Assembly Wiring Details 5 6 5 6 Model CYD200 D RJ 11 to DB 25 Adapter Wiring Details 5 6 5 7 Model CYD200 B RJ 11 to DE 9 Adapter Wiring Details 5 3 6 1 Serial Interface Adapters 6 3 L...

Страница 6: ...OMEGA Model CYD201 CYD208 User s Manual iv Table of Contents This Page Intentionally Left Blank...

Страница 7: ...ding this instrument Please return the instrument warranty card to ensure receipt of future software updates 1 1 MODEL CYD201 CYD208 GENERAL DESCRIPTION Model CYD201 CYD208 Digital Thermometers are id...

Страница 8: ...channels with selectable dwell times of 0 skip 5 10 30 and 60 seconds for each channel Connections Four lead sensor connection 2 current 2 voltage Response Curves Standard Curve 10 DT 500DI 8A also 8...

Страница 9: ...ded by the manufacturer WARNING Liquid helium is a potential asphyxiant and can cause rapid suffocation without warning Store and use in an adequately ventilated area DO NOT vent the container in conf...

Страница 10: ...F 40 C DO NOT rub the frozen part either before or after rewarming Protect the injured tissue from further damage and infection and call a physician immediately Flush exposed eyes thoroughly with warm...

Страница 11: ...e container An operator inserting or removing a device or assembly from a container must maintain contact with a conductive portion of the container Use only plastic bags approved for storage of ESD m...

Страница 12: ...Instrument Do not install substitute parts or perform any unauthorized modification to the instrument Return the instrument to an authorized OMEGA Cryotronics Inc representative for service and repair...

Страница 13: ...l shipping material is saved for their examination After examining and removing contents save packing material and carton in the event reshipment is necessary 2 2 REPACKAGING FOR SHIPMENT To return th...

Страница 14: ...l the National Electrical Manufacturer s Association NEMA recommends and some local codes require grounded instrument panels and cabinets The 3 conductor power cable when plugged into an appropriate r...

Страница 15: ...asurement Sometimes system constraints dictate two lead measurement Connect the positive terminals V and I together and the negative terminals V and I together at the instrument then run two leads to...

Страница 16: ...eft The OMEGA CY 7 SD silicon diode sensor lead configuration is shown to the right For other sensors read accompanying literature or consult the manufacturer to positively identify sensor leads Lead...

Страница 17: ...asurement error can approach several tenths of a kelvin To determine if this problem exists perform either procedure below 1 Place a capacitor across the diode to shunt induced AC currents Capacitor s...

Страница 18: ...on 1 V Input 1 2 V Input 1 3 V Input 2 4 V Input 2 5 V Input 3 6 V Input 3 7 V Input 4 8 V Input 4 9 V Input 5 10 V Input 5 11 V Input 6 12 V Input 6 Terminal Description 13 V Input 7 25 I Input 4 14...

Страница 19: ...in the Model CYD208 press CHANNEL to scroll through the eight channels To change the curve press UNITS The instrument scrolls through curves 0 through 6 In the Model CYD208 press CHANNEL to select ot...

Страница 20: ...A B A A B A 0 265 6 73 0 215 5 46 Model CYD201 or CYD208 Front Panel Hole Sizes A 0 189 0 480 Diameter 4 Places B 0 169 0 429 Diameter 2 Places C L 1 44 35 58 1 44 35 58 4 18 106 17 1 25 31 75 1 50 3...

Страница 21: ...a problem exists an error message displays on the front panel of the instrument Er01 indicates a hardware problem in the instrument memory This error is not user correctable First perform the procedur...

Страница 22: ...OMEGA Model CYD201 CYD208 User s Manual 2 10 Installation This Page Intentionally Left Blank...

Страница 23: ...Operation Paragraph 3 8 and Erasing SoftCal Compensations Paragraph 3 9 UNITS ON OFF CYD201 THERMOMETER K V C F Figure 3 1 Model CYD201 Front Panel CHANNEL UNITS ON OFF CYD208 THERMOMETER K V C F Fig...

Страница 24: ...60 seconds A dwell time of 0 instructs the thermometer to skip that particular channel To set the dwell 1 Hold CHANNEL for 3 seconds Do not release 2 While still pressing CHANNEL use UNITS to select...

Страница 25: ...2 Latched And Unlatched Alarms Alarms are either latched or unlatched The alarm is latched when the LATCH switch is in position 1 the alarm turns On when triggered by the alarm setpoint but will not a...

Страница 26: ...play rises release and press again 4 Press CAL ENABLE on rear panel with a pen tip The display reads SOF to indicate the unit is ready to erase the current SoftCal calibration Within 2 seconds press U...

Страница 27: ...SoftCal is set for above 28 K 3 6 3 Erasing SoftCal Compensations When SoftCal compensations are erased the thermometer returns to normal operation 1 Move the SET switch to position 1 2 Hold UNITS un...

Страница 28: ...OMEGA Model CYD201 CYD208 User s Manual 3 6 Operation This Page Intentionally Left Blank...

Страница 29: ...rial Interface Specifications Table 4 1 Serial Interface Connections Paragraph 4 1 1 Serial Interface Hardware Configuration and Adapters Figures 4 1 4 2 Serial Interface Operation Paragraph 4 1 2 and...

Страница 30: ...Connector Model CYD200 B RJ 11 to DB 25 Adapter Model CYD200 B RJ 11 to DE 9 Adapter Model CYD200 J10 RJ 11 Cable Assembly RS 232C Interface Output on rear of Model CYD201 or CYD208 Use whichever adap...

Страница 31: ...racters placed by the user or where they appear on a returning character string from the unit Leading zeros and zeros following a decimal point are not needed in a command string but they are sent in...

Страница 32: ...08 response PRINT B print instrument response REJUMP GOTO RESTART jump back to beginning FINISH CLOSE 1 close serial port END end exit program 4 2 SERIAL INTERFACE COMMAND SUMMARY Command Function Com...

Страница 33: ...L Select Low Alarm Setpoint Value Input Lxxx x Returned Nothing Remarks Sets low alarm setpoint where xxx x temperature setpoint in units specified by F0 command If the instrument is set for volts th...

Страница 34: ...current input channel The instrument skips every channel with a dwell time of zero WA Switch ID and Alarm Data Input WA Returned For a Model CYD201 returns switch ID high or low alarm alarm sign alarm...

Страница 35: ...ctive and I inactive WY Scan Status Model CYD208 Only Input WY Returned scan status current channel number channel which caused the alarm state channel 1 dwell time channel 2 dwell time channel 8 dwel...

Страница 36: ...OMEGA Model CYD201 CYD208 User s Manual 4 8 Remote Operation This Page Intentionally Left Blank...

Страница 37: ...ar 4 pin connector temperature sensor 201 MC J2 SERIAL I O RJ 11 jack for serial remote communications to a host computer May require accessories CYD200 J10 RJ 11 phone cord and CYD200 D RJ 11 to DB 2...

Страница 38: ...and CYD200 D RJ 11 to DB 25 adapter J3 ALARM Relay responds to alarm setpoints and can trigger another device Contact 1 is normally open contact 2 is normally closed FIX switch Switches alarm functio...

Страница 39: ...7 before the unit can be used OL indicates a voltage input overload This can be caused by an open sensor or diode sensor wired backwards Before calling the factory about a persistent problem try the p...

Страница 40: ...e selected 5 Replace enclosure cover rear panel and all screws 5 6 Line Voltage Configuration The rear panel 3 pronged line power connector permits Model CYD201 CYD208 operation at either 110 or 220 V...

Страница 41: ...volves current source and analog digital A D converter calibration A D calibration erases all SoftCal compensations perform it after current source calibration not before 5 7 1 Current Source Calibrat...

Страница 42: ...CAL ENABLE then within 2 seconds press UNITS The display window shows CAL for approximately 15 seconds 6 Repeat procedure with 25 k resistor 7 For Model CYD208 repeat procedure for other 7 channels S...

Страница 43: ...OMEGA Model CYD201 CYD208 User s Manual Service 5 7 5 4 3 2 1 9 8 7 6 NOT USED 6 5 4 3 2 1 DE 9 CONNECTOR RJ 11 RECEPTACLE Gnd RxD TxD Figure 5 7 Model CYD200 B RJ 11 to DE 9 Adapter Wiring Details...

Страница 44: ...OMEGA Model CYD201 CYD208 User s Manual 5 8 Service This Page Intentionally Left Blank...

Страница 45: ...1 2010 Model CYD201 calibration connector 2080 Model CYD208 calibration connector 2081 Screw Terminal Adapter Connects Model CYD208 to multiple sensor probe assemblies with stripped ends and non perm...

Страница 46: ...pper disk 30 AWG copper leads anchored to disk Mass excluding leads 4 3 grams 2084 Multi Connector Adapter Required with Model CYD208 when using multiple probe cable assemblies and Model 201 MC mating...

Страница 47: ...Diode Temperature Sensor Repeatable interchangeable accurate wide range customized for cryogenics Series DT 471 An economical version of the CY 7 for applications where temperature measurements below...

Страница 48: ...OMEGA Model CYD201 CYD208 User s Manual 6 4 Options and Accessories This Page Intentionally Left Blank...

Страница 49: ...1 31868 23 0 1 26476 24 24 0 1 21712 23 25 0 1 17857 22 26 0 1 15106 21 27 0 1 13317 20 28 0 1 12169 19 29 0 1 11353 18 30 0 1 10729 17 32 0 1 09810 16 34 0 1 09125 15 36 0 1 08547 38 0 1 08038 14 40...

Страница 50: ...1 09178 13 36 0 1 08559 12 38 0 1 07992 40 0 1 07502 45 0 1 06307 50 0 1 05136 55 0 1 03951 11 60 0 1 02744 65 0 1 01475 70 0 1 00193 10 75 0 0 98892 77 4 0 98264 80 0 0 97557 85 0 0 96216 90 0 0 9487...

Страница 51: ...1 0970 15 34 0 1 0902 36 0 1 0850 38 0 1 0798 14 40 0 1 0746 45 0 1 0633 50 0 1 0520 13 55 0 1 0407 60 0 1 0287 65 0 1 0166 12 70 0 1 0046 75 0 0 99172 80 0 0 97890 85 0 0 96609 11 90 0 0 95327 95 0 0...

Страница 52: ...20 26 0 1 1559 19 27 0 1 1365 18 28 0 1 1239 17 29 0 1 1150 16 30 0 1 1080 15 32 0 1 0981 14 34 0 1 0909 13 36 0 1 0848 38 0 1 0797 12 40 0 1 0746 45 0 1 0630 50 0 1 0515 55 0 1 0399 11 60 0 1 0284 6...

Страница 53: ...35 21 60 0 1 0100 20 65 0 0 9958 70 0 0 9822 75 0 0 9690 19 77 4 0 9626 80 0 0 9560 18 85 0 0 9440 17 90 0 0 9314 16 95 0 0 9184 15 100 0 0 9049 105 0 0 8907 14 110 0 0 8769 13 115 0 0 8625 120 0 0 85...

Страница 54: ...1 0 1 1039 32 0 1 0991 15 33 0 1 0949 34 0 1 0913 14 35 0 1 0879 36 0 1 0850 37 0 1 0822 13 38 0 1 0795 39 0 1 0770 40 0 1 0746 42 0 1 0697 12 44 0 1 0649 46 0 1 0603 48 0 1 0558 50 0 1 0512 52 0 1 04...

Страница 55: ...19 0 1 23184 19 5 1 22314 23 20 0 1 21555 21 0 1 19645 22 0 1 17705 23 0 1 15558 22 24 0 1 13598 21 25 0 1 12463 20 26 0 1 11896 19 27 0 1 11517 18 28 0 1 11202 29 0 1 10945 30 0 1 10702 17 31 0 1 104...

Страница 56: ...45858 330 0 0 44647 335 0 0 43435 5 340 0 0 42238 345 0 0 41003 350 0 0 39783 355 0 0 38561 360 0 0 37337 365 0 0 36110 370 0 0 34881 375 0 0 33650 380 0 0 32416 385 0 0 31180 4 390 0 0 29958 395 0 0...

Страница 57: ...NOTES...

Страница 58: ...NOTES...

Страница 59: ...and Process Monitors Data Acquisition Modules and Data Loggers Computer Sensor Interface PRESSURE STRAIN Transducers Strain Gauges Load Cells Pressure Gauges Instrumentation FLOW Rotameters Flowmeter...

Страница 60: ......