10
r 1
r 1
r 1
r 1
r 1 =Input Type and Range Value
=Input Type and Range Value
=Input Type and Range Value
=Input Type and Range Value
=Input Type and Range Value
0 = TC J
From
-100 to
1000
°C
1 = TC K
From
-100 to
1370
°C
2 = TC T
From
-200 to
400
°C
3 = TC E
From
-100 to
800
°C
4 = TC N
From
-100 to
1400
°C
5 = TC S
From
-50 to
1760
°C
6 = TC R
From
-50 to
1760
°C
7 = TC B
From
0 to
1820
°C
8 = TC L
From
-100 to
900
°C
9 = TC U
From
-200 to
600
°C
10 = TC G
From
0 to
2300
°C
11 = TC D
From
0 to
2300
°C
12 = TC C
From
0 to
2300
°C
13 = TC Plat. II
From
-100 to
1400
°C
14 = RTD Pt 100 From
-200 to
850
°C
15 = Linear
From
0 to
60 mV
16 = Linear
From
12 to
60 mV
17 = Linear
From
0 to
20 mA
18 = Linear
From
4 to
20 mA
19 = Linear
From
0 to
5
V
20 = Linear
From
1 to
5
V
21 = Linear
From
0 to
10
V
22 = Linear
From
2 to
10
V
23 = TC J
From
-150 to
1830
°F
24 = TC K
From
-150 to
2500
°F
25 = TC T
From
-330 to
750
°F
26 = TC E
From
-150 to
1470
°F
27 = TC N
From
-150 to
2550
°F
28 = TC S
From
-60 to
3200
°F
29 = TC R
From
-60 to
3200
°F
30 = TC B
From
32 to
3300
°F
31 = TC L
From
-150 to
1650
°F
32 = TC U
From
-330 to
1110
°F
33 = TC G
From
0 to
4170
°F
34 = TC D
From
0 to
4170
°F
35 = TC C
From
0 to
4170
°F
36 = TC Plat. II
From
-150 to
2550
°F
37 = RTD Pt100 From
-330 to
1560
°F
r2 = Decimal Point Position
r2 = Decimal Point Position
r2 = Decimal Point Position
r2 = Decimal Point Position
r2 = Decimal Point Position
(Available only for linear range r1 = 15 to 22)
_ _ _ _ .
_ _ _ _ .
_ _ _ _ .
_ _ _ _ .
_ _ _ _ .
= No decimal
_ _ _ . _
_ _ _ . _
_ _ _ . _
_ _ _ . _
_ _ _ . _
= One decimal figure
_ _ . _ _
_ _ . _ _
_ _ . _ _
_ _ . _ _
_ _ . _ _
= Two decimal figures
_ . _ _ _
_ . _ _ _
_ . _ _ _
_ . _ _ _
_ . _ _ _
= Three decimal figures
r3 = Initial value of the readout scale
r3 = Initial value of the readout scale
r3 = Initial value of the readout scale
r3 = Initial value of the readout scale
r3 = Initial value of the readout scale
(Available only for linear range r1 = 15 to 22)
Range: From -1999 to 9999
r4 = final value of the readout scale
r4 = final value of the readout scale
r4 = final value of the readout scale
r4 = final value of the readout scale
r4 = final value of the readout scale
(Available only for linear range r1 = 15 to 22)
Range: From -1999 to 9999
r5 = Offset Adjustment
r5 = Offset Adjustment
r5 = Offset Adjustment
r5 = Offset Adjustment
r5 = Offset Adjustment
Range: From -500 to 500
Offset value algebraically added to the measured
value.
r6 =
r6 =
r6 =
r6 =
r6 =Time constant of the filter applied to
Time constant of the filter applied to
Time constant of the filter applied to
Time constant of the filter applied to
Time constant of the filter applied to
the displayed value
the displayed value
the displayed value
the displayed value
the displayed value
Range: From 0 (filter OFF) to 8 seconds.
(First order filter with selected time constant.)
r7 = Alarm action on input fault.
r7 = Alarm action on input fault.
r7 = Alarm action on input fault.
r7 = Alarm action on input fault.
r7 = Alarm action on input fault.
When the instrument detects an input failure
condition, the alarm will operate as in presence of:
uP = as in presence of the full scale value.
doun = as in presence of the initial scale value.
C1 = Type of limit action
C1 = Type of limit action
C1 = Type of limit action
C1 = Type of limit action
C1 = Type of limit action