23
STANDARD RANGES TABLE
D) LOGIC INPUTS
D) LOGIC INPUTS
D) LOGIC INPUTS
D) LOGIC INPUTS
D) LOGIC INPUTS
(for models with RS-485 only)
(for models with RS-485 only)
(for models with RS-485 only)
(for models with RS-485 only)
(for models with RS-485 only)
This instrument is provided of 1 logic input used
for remote acknowledgement.
NOTES
NOTES
NOTES
NOTES
NOTES
1) Use an external dry contact capable of
switching 0.5 mA, 5 V DC.
2) The instrument needs 100 ms to recognize a
contact status variation.
3) The logic inputs are NOT
NOT
NOT
NOT
NOT isolated by the
measuring input.
OUTPUTS
OUTPUTS
OUTPUTS
OUTPUTS
OUTPUTS
Output updating time
Output updating time
Output updating time
Output updating time
Output updating time :
- 250 ms when a linear input is selected
- 500 ms when a TC or RTD input is selected.
OUTPUT 1
OUTPUT 1
OUTPUT 1
OUTPUT 1
OUTPUT 1
Type: relay
Type: relay
Type: relay
Type: relay
Type: relay SPDT contact .
Contact rated
Contact rated
Contact rated
Contact rated
Contact rated: 3 A at 250 V AC on resistive load.
Function
Function
Function
Function
Function: Safety limiter output.
Action
Action
Action
Action
Action: reverse (fail-safe).
OUTPUT 2
OUTPUT 2
OUTPUT 2
OUTPUT 2
OUTPUT 2
Type: relay
Type: relay
Type: relay
Type: relay
Type: relay SPST contact .
Contact rated
Contact rated
Contact rated
Contact rated
Contact rated: 2 A at 250 V AC on resistive load.
Function
Function
Function
Function
Function: Alarm output
Action
Action
Action
Action
Action: direct/reverse programmable by front
keyboard.
ALARM
ALARM
ALARM
ALARM
ALARM
Action
Action
Action
Action
Action: Direct or reverse acting.
Alarm functions
Alarm functions
Alarm functions
Alarm functions
Alarm functions: configurable as process alarm,
band alarm or deviation alarm.
Alarm reset
Alarm reset
Alarm reset
Alarm reset
Alarm reset: automatic reset, manual reset or
"Silence" function is programmable.
Stand by (mask) alarm
Stand by (mask) alarm
Stand by (mask) alarm
Stand by (mask) alarm
Stand by (mask) alarm: the alarm can be
configured with or without stand by (mask)
function.
Process alarm
Process alarm
Process alarm
Process alarm
Process alarm:
Operative mode
Operative mode
Operative mode
Operative mode
Operative mode : High or low programmable.
Threshold
Threshold
Threshold
Threshold
Threshold : programmable in engineering unit within
the readout span.
Hysteresis
Hysteresis
Hysteresis
Hysteresis
Hysteresis: programmable from 0.1 % to 10.0 % of
the readout span.
Input type
Input type
Input type
Input type
Input type
15
16
17
18
19
20
21
22
0 - 60 mV
0 - 60 mV
0 - 60 mV
0 - 60 mV
0 - 60 mV
12 - 60 mV
12 - 60 mV
12 - 60 mV
12 - 60 mV
12 - 60 mV
0 - 20 mA
0 - 20 mA
0 - 20 mA
0 - 20 mA
0 - 20 mA
4 - 20 mA
4 - 20 mA
4 - 20 mA
4 - 20 mA
4 - 20 mA
0 - 5 V
0 - 5 V
0 - 5 V
0 - 5 V
0 - 5 V
1 - 5 V
1 - 5 V
1 - 5 V
1 - 5 V
1 - 5 V
0 - 10 V
0 - 10 V
0 - 10 V
0 - 10 V
0 - 10 V
2 - 10 V
2 - 10 V
2 - 10 V
2 - 10 V
2 - 10 V
impedance
impedance
impedance
impedance
impedance
> 1 M
Ω
< 5
Ω
> 400 k
Ω
> 400 k
Ω
Accuracy
Accuracy
Accuracy
Accuracy
Accuracy
0.2 % + 1 digit
@ 25°C
(77 °F)
LHL-1-NEUTRO.pmd
19/04/2004, 15.07
23