9 Installation
9.1 General requirements for installation
The RDP refrigeration air dryer is designed to operate in an environment that ensures the following
conditions:
•
Internal installation, clean and dry space
•
Non-aggressive atmosphere
•
The minimum ambient temperature is +1,5
° C
•
The maximum ambient temperatu
re is +45 ° C
•
Ensure adequate ventilation to cool the device
•
Installation without vibration (refers to the floor and pipes)
•
For maintenance and servicing, provide sufficient space for uninhibited work around the unit
(1 m).
•
The ventilation grilles of the device must not be covered for the operation of the system
The air supplied to the refrigeration air dryer must satisfy the following conditions:
•
The quality of compressed air 2 for particulate matter (if the dryer is equipped with a super
fine coalescent filter 0,01um)
•
The quality of compressed air 2 for oil particles (if the dryer is equipped with a super fine
coalescent filter 0,01um)
•
Absence of aggressive substances