8
Installation
•
The installation must conform to local codes, or in absence of local codes, with the standard for the storage
and handling of liquid petroleum gases.
•
A dented, rusted or damaged propane tank may be hazardous and should be checked by your tank
supplier. Never use a propane tank with a damaged valve connection.
•
The propane tank must be arranged to provide for vapor withdrawal from the operating cylinder.
•
Never connect an unregulated propane tank to the heater.
LEAKAGE TEST
Gas connections on the heater are leak tested at the factory prior to shipment. A complete gas tightness check
must be performed at the installation site due to possible mishandling in shipment or excessive pressure being
applied to the heater.
• Make a soap solution of one part liquid detergent and one part water. The soap solution can be applied with
a spray bottle, brush or rag. Soap bubbles will appear in case of a leak.
•
The heater must be checked with a full cylinder.
•
Make sure the safety control valve is in the OFF position.
•
Turn the gas supply ON.
• In case of a leak, turn off the gas supply. Tighten any leaking fittings, then turn the gas supply on and
recheck.
•
Never leak test while smoking.
ASSEMBLY PROCEDURES
STEP 1
•
Put the 3 pcs. post brackets on each position on the base.
• Use 3 medium bolts (M8x16) to join the post brackets and stand.