Troubleshooting
Problem
Possible Cause
Solution
Pilot will not light.
Gas valve may be off.
Turn the gas valve on.
Tank fuel is empty.
Refill LPG tank.
Opening blocked.
Clean or replace opening.
Air in supply system.
Purge air from lines.
Loose connections.
Check all fittings.
Pilot will not stay on.
Debris around pilot.
Clean dirty area.
Loose connections.
Tighten connections.
Bad thermocouple.
Replace thermocouple.
Gas leak in line.
Check connections.
Lack of fuel pressure.
Tank near empty. Refill LPG tank.
Burner will not light
Pressure is low.
Tank near empty. Refill LPG tank.
Opening blocked.
Remove and clean.
Control is not on.
Turn valve to on.
Bad thermocouple.
Replace thermocouple.
Pilot light assembly is bent.
Place pilot properly.
Not in the correct location.
Position properly and retry.
If the appliance has any faults or problems during assembly or use, please don’t try to modify it yourself.
Contact Omcan for assistance.