safety and warranty

Sufficient space

To allow for proper air circulation and increased 

refrigeration capabilities, the refrigerator must have at 

least 4”/10cm of space between wall/ceiling and the 

machine.

Proper ventilation

Always place the refrigerator in an area with good 

ventilation. For first time use, set in location and wait 

at least 2 hours before plugging into wall socket.

Away from heat source

Never place the refrigerator near any type of heat 

source or in direct sunlight, as it reduces refrigeration 

capabilities.

No heavy load

Never put heavy items on top of the refrigerator.

No altercations/tampering

Never tamper with or make changes to the 

refrigerator. Changes and add-ons should not be 

installed to the inside or outside of the refrigerator.

Stable location

Unpack and place the refrigerator on flat, solid 

ground.

PREPARATION AND POwER SUPPLY

Exclusive power outlet

Power supply should be 110V, single phase AC with 

exclusive single phase three pin outlet (125V/15A). 

The power outlet must be in close proximity to the 

ground.

No shared power outlets

Refrigerator cable should never share the power 

outlet with any other appliance, as cable will overheat 

and may result in a fire.

Protect cables

Extra caution should be used when handling cables, 

as broken or damaged cables can cause sparking 

and may result in a fire.

No water flushing

Never flush the refrigerator surface. This can cause 

leakage, which may result in electrical damage or fire.

Never store flammables and explosives

No explosives or flammables should be stored in, 

or in proximity to, the refrigerator, such as gasoline, 

alcohol, and adhesives.

No spray

Never spray flammables such as paint or coating 

near the refrigerator. This may cause fire or 

malfunction.

After power outage

After a power outage or the unplugging of the 

refrigerator, wait at least 5 minutes before plugging it 

back in.

No medicine

Medicine should not be stored inside of the 

refrigerator.

RESIDENTIAL USERS: Vendor assumes no liability for parts or labor coverage for component failure 

or other damages resulting from installation in non-commercial or residential applications. The right 

is reserved to deny shipment for residential usage; if this occurs, you will be notified as soon as 

possible.

1 YEAR PARTS AND LABOUR wARRANTY

Within the warranty period, contact Omcan Inc. at 1-800-465-0234 to schedule an Omcan authorized 

service technician to repair the equipment locally.

Содержание BB-CN-230S

Страница 1: ...Back Bar Cooler Model BB CN 230S Item 47587 Instruction Manual Revised 02 16 2023 Toll Free 1 800 465 0234 Fax 905 607 0234 Email service omcan com www omcan com...

Страница 2: ...4 15 Table of Contents Section Disclaimer General Information Safety and Warranty Technical Specifications Installation Operation Maintenance Troubleshooting Parts Breakdown Electrical Schematics Note...

Страница 3: ...causados por fugas de agua La garant a por fugas de agua queda anulada si la temperatura ambiente supera los 75 F y el 55 de humedad relativa y el desag e del aparato no est conectado directamente a...

Страница 4: ...e It s of the utmost importance to save these instructions for future reference Also save the original box and packaging for shipping the equipment if servicing or returning of the machine is required...

Страница 5: ...nspeccionar da os externos Si no hay da os evidentes en el empaque exterior Habra el carton para asegurararse que todos los articulos solicitados sten dentro de la caja y no encuentre da os ocultos en...

Страница 6: ...ower outlet with any other appliance as cable will overheat and may result in a fire Protect cables Extra caution should be used when handling cables as broken or damaged cables can cause sparking and...

Страница 7: ...products separately differentiated waste according to the current norms DO NOT DISCARD ANY PACKAGING MATERIALS IN THE ENVIRONMENT Technical Specifications Model BB CN 230S Capacity 208 L 7 34 cu ft Te...

Страница 8: ...failure General Operation The cabinet door should remain firmly closed during normal operation This prevents warm moist air from entering and creating frost within the cabinet If the cabinet is left...

Страница 9: ...al components Must not be cleaned by a water jet Always wipe dry after cleaning with soft cloth Take care when cleaning the rear of the cabinet An agent or qualified technician must carry out repairs...

Страница 10: ...n Ambient temperature is too high Increase ventilation or move appliance to a cooler position Appliance is overloaded Reduce the amount of containers in the appliance The appliance is unusually loud L...

Страница 11: ...11 Parts Breakdown Model BB CN 230S 47587...

Страница 12: ...586 Drain Pan for 47587 23 AM602 Evaporator Fan Support for 47587 38 AM571 Condenser for 47587 8 AM587 Drain Pipe for 47587 24 AM603 Support Long for 47587 39 AM572 Condenser Fan for 47587 9 AM588 Spr...

Страница 13: ...13 Electrical Schematics Model BB CN 230S 47587...

Страница 14: ..._______________ ________________________________________________________________________________________ ________________________________________________________________________________________ ______...

Страница 15: ...ter online by visiting OMCAN PRODUCT WARRANTY REGISTRATION 3115 Pepper Mill Court Mississauga Ontario Canada L5L 4X5 https omcan com warranty registration or email to service omcan com Purchaser s Inf...

Страница 16: ...relations avec nos clients et les fabricants de valeur Aujourd hui avec des partenaires en Am rique du Nord Europe Asie et Am rique du Sud nous travaillons continuellement am liorer et d velopper l e...

Отзывы: