9
Installation
ELECTRICAL CONNECTION
WARNING
All wiring must conform to local, state and national regulations.
•
This ice maker must be plugged into an independent power source, or an electrical socket of voltage at
specified range.
•
This ice maker must be connected with an independent fuse / circuit breaker.
WATER SUPPLY AND DRAIN CONNECTION
• Check if there is a need to install water treatment & filter system based on the local water situation. This
can avoid the formation of precipitates, filter impurities and remove the smell of bleach.
• Water supply pressure should be minimum 0.14Mpa and maximum 0.55Mpa. If the pressure exceed
0.55Mpa use a pressure reducing valve. Do NOT bend the supply tap.
• A plumbing permit and service of a licensed plumber may be required in some area.
•
Water should drain into an open trap.
• Ice maker drain is gravity flow. Please ensure drain pipe has an adequate pitch or fall.
WARNING
Piping installation must conform to relevant regulations.
WARNING
The machine must be plugged into a properly grounded outlet and electricity supply as per rating plate.
• To prevent a backflow into machine, please refer to the below image for installing water drain pipe.