26
Never try to change or move any part inside the amplifier except the tube or fuses.
Substitution of parts may void intrinsic safety!
Manufacturer’s contacts: OM POWER, s.r.o.
930 30 Báč 126
SLOVAKIA
Email:
Dealer in the USA:
Array Solutions
2611 North Belt Line Road
Suite # 109
Sunnyvale, TX 75182
Tel:
(214)954-7140
Email:
sales@arraysolutions
.
com
6.2.
Fuse replacement
The user is allowed to change mains fuses (6.3 x 32mm), accessible from the rear panel, only. In the case
of fuse (fuses) interruption inside the power amplifier,
exchange can be carried out only by professionally
qualified persons!
Internal fuses are located mainly on the SW ON board (next to the HV transformer).
One special fuse
F 4A
, filled with sand, is used in
the model . In the case of an accidental
discharges or short within the tube this fuse (4
Amps fast, filled with sand) saves the HV supply
circuits.
6.3.
Tube Replacement
In the case of a damaged vacuum tube , contact the manufacturer or your dealer for ordering a new one.
We will provide instructuions for replacing the tube.
Replacement should be done by a professionally
qualified person!
After tube replacement the
automatic BIAS adjustment
procedure must be done.
6.4.
Cleaning
To prevent damage to the amplifier surface and plastic components, do not use aggressive chemicals for
cleaning. Do not open the amplifier for cleaning. Outer surface cleaning may be safely accomplished by
using a piece of soft cotton cloth moistened with clean water or window cleaner.
Type of supported TCVR and working
frequency are visible on the display.
AUTO LED is ON.