22
5.3.
Operation mode
CAUTION
In STBY the amplifier is in bypass-mode and your transceiver is directly connected to the antenna.
Maximum allowed power in bypass mode is 100 Watts! Passing RF power is measured with analog
wattmeter only. It is not displayed if PA is either in standby mode or turned OFF.
Press
OPER
to activate operation mode.
STBY
LED switched OFF.
Changing of
DSP
allows user to watch couple
of basic parameters of the PA in operation
mode without input RF signal. Notice: These
are three default display settings (software
version 6.1.)
Check all connections again. Set BAND selector, TUNE and LOAD capacitors according to TCVR
parameters and delivered tuning table (see next part for more details). Apply
low
input power
and press
PTT. Check Analog wattmeter first. Try to tune PA for maximum output power and minimum SWR.
Type of supported TCVR and working
frequency are visible on the display.
AUTO LED is ON.
Содержание OM2000+