background image

the  device’s  back  up  operation  and 
emergency duration. This test is conducted 
automatically  every  6  months

In  order  to 

be performed, the mains power supply and 
the  battery  should  be  connected  and  fully 
charged

If the battery is not fully charged

the  test  is  postponed

 

until  the  battery  is   

completely  charged.  If  during  this  test,  the 
autonomy is less than the nominal then the 
battery  fault  led  will  turn  on  continuously 
and the battery must be replaced. 

Back Up Operation

The autonomous duration of battery during 
emergency mode is at least the one that is 
stated  in  the  list  of  the  technical 
characteristics. During emergency mode, a 
light source test is also performed.

Resetting Errors

Push  the  test  button  for  >10  seconds  to 
delete  all  indicated  errors.  Then  the 
luminaire enters regular operation mode.

INSTALLATION

To 

install 

the 

luminaire 

follow 

the 

installation instructions on page 3.

ΑΤΤΕΝΤΙΟΝ

!!!

1. Operations for installation, maintainance 
or  testing  must  be  done  by  authorized 
personnel only

.

2. 

The  device  must  be  connected  to  the 

mains  power  supply  through  a  fuse 
dependent by the total amount of the line’s  
power load

.

3. 

In case of battery or lamp replacement, 

these  must  be  replaced  by  parts  of  the 
same  type,  by  the  manufacturer  or  by  a 
competent person.

4.  In  case  of  inactive  use  for  a  period 
greater  than  2  months,  disconnect  the 
battery  by  pulling  out  the  battery’s 
connector. 
5

I

s  not  allowed  to  discard  batteries 

t  i

into common trash bins, they must 
be  discarded  only 

 

in  battery 

recycling points. Do not incinerate.

The  light  source  contained  in  this 

luminaire  shall  only  be  replaced  by 
the  manufacturer,  or  his  agent,  or  a 

similar qualified person.

NOTE!  The  light  source  is  non-user 
replaceable.

Connection to module

This  luminary  can  be  connected  to  any  of 
the  following  modules:  Remote  module, 
address  module  and  fault  relay  module.  If 
you  connect  it  to  a  module  that  supports 
inhibit  or  rest  mode,  you  should  know  that 
these  commands  can  be  cancelled  only 
during normal mode (ie. not in emergency). 
You  can  also  refer  to  the  user  manual  of 
each module for additional information. The 
picture  bellow  shows  the  installation  of  the 
optional module.

GREEN

RED

RED

Description

Battery charged no faults

Charging (battery test not possible while charging)

Mains off, battery not connected or charger fault

Battery test

Battery fault

Light source test

Light source fault

Battery fault and light source fault 

Off

On

Flashing

Led status explanation

 

Indicator LEDs

Page 2 from

 

6

Picture 1

923064003_09_00

2

Содержание LLB-26/90

Страница 1: ...est is performed This test will last for the stated duration and can only be performed when the battery is fully charged steady green LED The white LEDs will be lit and the red LED will flash during this test sequence Automatic Autonomous Test The Automatic Autonomous Test measures SELF TESTING MAINTAINED EMERGENCY LUMINAIRIES WITH LEDs OPERATION TEMPERATURE RANGE RELATIVE HUMIDITY VIEWING DISTANC...

Страница 2: ... lamp replacement these must be replaced by parts of the same type by the manufacturer or by a competent person 4 In case of inactive use for a period greater than 2 months disconnect the battery by pulling out the battery s connector 5 I s not allowed to discard batteries t i into common trash bins they must be discarded only in battery recycling points Do not incinerate The light source containe...

Страница 3: ...ire and use the two supplied mounting screws to install the aluminum bracket to the plastic bracket figure 2 Slide the luminaire to the aluminum bracket and use the bolt on the center to stabilize the luminaire figure 2 CEILING MOUNTING double sided Remove the aluminum bracket from the luminaire and install it with the included spacers screws and plugs in the ceiling page 3 Slide the luminaire to ...

Страница 4: ...Figure 2 Side view Figure 1 GENERAL Measure the distance of the mounting holes and after the drilling place on these spots the mounting plugs and fasten the base with the mounting screws Figure 3 Front view Figure 4 Aluminum bracket Plastic bracket Page 4 from 6 1 2 SIDE WALL CLEARANCE Depending on the size of the luminaire the distance from the side wall must be more than LLB 26 440mm LLB 40 580m...

Страница 5: ...INSTALLATION double side luminaire A 1136 SET OPTIONAL AFTER REQUEST INSTALLATION PICTOGRAMMS 1 Unfasten the two screws of the luminaire and remove the top part of the luminaire 2 Insert the pictogramm after removing the protective film from the back side 3 Carefully fit the top aluminium cover and reinstall the retaining screws 923064003_09_002 ...

Страница 6: ...ectronics gr info olympia electronics gr Battery replacement process Maintained operation The luminaire lights its illumination source when it is powered by the mains power supply or not It can be done only by a competent person and after the mains interruption 1 Unfasten the two side cover screws and remove the plastic cap with the indications by sliding it gently to the right 2 Remove the old ba...

Отзывы: