background image

Page 9 

921468007_90_005 

 

5.

 

If 32 devices are already installed and a user tries to add another, 4 long beeps 
will be heard. No other devices can be installed. 

6.

 

By pressing "#

ESC

"

 

the installation procedure stops. 

 

NOTE:

 For every change in the wireless zone menu and during the extensions 

scan,  an  amount  of  time  is  needed  in  order  to  update  the  data  of  the  wireless 
system. During this time, when we try to enter a menu, a waiting message appears. 
When the update process is complete, the menus can be used as usual. 

 

NOTE:

 The above process could be followed with another way as well. 

First mount all the devices with their batteries to their positions and then enter the 
network  installation  menu.  The  devices  will  be  automatically  installed  in  5-10 
minutes. If you would like to speed up the process, you can go and press the tamper 
in the devices one by one. 

 

3. 

DEVICE’S INSTALLATION

 

 

3.1 Range testing using wireless keypad                                                                                                                                                                                                                                                                                                                                                            

By choosing "SIGNAL STRENGTH" the technician can move to each device's position 
and check the signal strength at the specific location. 

By  entering  the  technician  menu,  go  to  "WIRELESS  NETWORK" 

  "SIGNAL 

STRENGTH".  The  value  shown  on  the  screen  is  the  signal  strength  on  the  specific 
position. This value is refreshed every few seconds. When refresh occurs, 4 flashing 
dots appear on screen. Prices above 30 means good signal, 19 to 30 average signal, 
and below 19 means "low signal". Beyond this value communication is possible, but 
there will be a large number of lost packets. It is not recommended to install a device 
when the mark is below 20. If at some point there is insufficient signal for a device, 
think  of  a  better  place  to  place  the  panel.  The  position  of  the  panel  is  of  key 
importance  for  the  quality  of  the  wireless  network.  It  is  suggested  to  wait  10-20 
seconds at  each  point  to  see  that  the  signal  is not  fluctuating.  The  4  dashes  at the 
bottom  of  the  screen  should  be  also  blinking  regularly.  Note  that  any  presence  of 
material  between  the  device  and  the  board  will  affect  the  signal  strength  to  a 
greater or lesser extent, depending on the material. Do not place the panel in metal 
or behind metal-covered areas. 

3.2 Final placement of wireless devices 

 

Remove the batteries from all devices except the wireless keypad. 

Press "#

ESC

to return to the home screen and let it turn off in order to save battery power. 

 

Place every wireless device on its final place

 (e.g. magnetic traps on doors, siren 

on  outer  space,  etc).

 

Activate  the  wireless  keypad  with  the  touch  of  your  palm 

and  enter  the  technician  menu.  Put  the  batteries  on  all  devices  and  close  their 
lids. The user can refer to each device's instruction manual separately. Be aware 

Содержание BS-468/A

Страница 1: ...WIRELESS BURGLAR ALARM SYSTEM BS 468 A QUICK INSTALLATION GUIDE...

Страница 2: ...S DEVICES 9 4 STARTING UP THE INSTALLED SYSTEM 10 4 1 SYSTEM CONFIGURATION 10 4 2 INSTALLATION COMPLETION 11 5 DEVICES INSTALLATION 11 5 1 Generals 11 5 2 Device s control operation 12 6 BASIC SYSTEM...

Страница 3: ...20 8 1 General 20 8 2 Installation 21 8 3 Codes registration procedure on rf 467 21 8 4 CODES DELETION PROCEDURE ON RF 467 22 9 System s app 22 9 1 Program for PC PC 468 A 22 9 2 Mobile app i olympia...

Страница 4: ...ion in addition to this manual please refer to the BS 468 A manual which is also enclosed within the kit as well as the instructions for the individual devices that are enclosed in the packaging of ea...

Страница 5: ...arm panel 1 PC BS 479 32 wireless zone expansion module for BS 468 A 1 PC RF 467 Remote control transmitter 433MHz for BS 468 BS 468 A panel 2 PCS YET205B 630 MODULE RECEIVER 433MHz RECEIVER MODULE 4...

Страница 6: ...lease refer to the user manual Section 3 6 Programming via computer B BS 466 A wired Keyboard The installation process through the wired keyboard is the same as that of the wireless keyboard in steps...

Страница 7: ...ncludes the devices detection and the second installs a wireless keypad When the BS 477 wireless keypad is installed the installation of the other devices can be completed by the keypad menu In order...

Страница 8: ...carried out by the menu NETWORK INSTALLATION 1 Press Go to MASTER OR TECH MENU By entering the technician code the user has now TECHNICIAN privileges 2 Go to WIRELESS NETWORK Press Choose NETWORK INST...

Страница 9: ...d every few seconds When refresh occurs 4 flashing dots appear on screen Prices above 30 means good signal 19 to 30 average signal and below 19 means low signal Beyond this value communication is poss...

Страница 10: ...IRELESS TAMPERS This feature allows the user to monitor in real time whether the tamper spring of each wireless device installed on the network is pressed or not The numbers displayed are the wireless...

Страница 11: ...all them on the system The installation procedure has come to its end You have set up an operating system and you know all the basic details to operate this system You can try an arm disarm test to ch...

Страница 12: ...D on the radar lights up and the keypad screen changes Let it be noted that radars turn on the LED on each activation only in the technician menu Be careful if a zone is in Disabled Off mode The senso...

Страница 13: ...added when entering in an armed system This extra time is rarely used It is suggested that NEXT DELAY zones to be placed in a separate section So some user could have one section with motion sensors...

Страница 14: ...Page 14 921468007_90_005 7 HANDLING THE SYSTEM WITH THE WIRELESS KEYPAD 7 1 Key Operations and Functions of the Wireless Keyboard...

Страница 15: ...EVICE ASSIGN ZONE NETWORK INSTALLATION DELETE SINGLE ZONE DELETE ALL ZONES RF COMM SUPERVISION WIRELESS TAMPERS WIRELESS SENSORS SIGNAL STRENGTH SIREN LED SETTING RF MASTER INFO 7 2 Basic Menu Passwor...

Страница 16: ...s locked Therefore once the device is switched on it is not necessary for the user to press first but can press for 5 seconds and send a panic alarm 7 4 Basic handling and settings The panel has 1 mai...

Страница 17: ...sarm each subsystem The arming of one subsystem does not affect the status armed disarmed of the other subsystems If during the arming procedure a zone is active then the keyboard shows the message Wh...

Страница 18: ...is means that it is disabled but would prevent the panel from arming if it was not disabled Selecting BYPASS W LESS ZONES we see The same applies for wireless zones The only difference is that the zon...

Страница 19: ...this is the 70th event of a total of 70 events With the up and down arrow keys 2 and 8 the user can see all the registered events The event memory has a capacity of 250 events and once filled the new...

Страница 20: ...alarm event only if the system is armed While the system is disarmed an information on the WIRELESS SENSORS menu screen is depicted If a wireless device does not communicate with the panel for a long...

Страница 21: ...tions A System arming B System disarming C Silent alarm D Panic alarm Photo 1 RF 467 Photo 2 BS 468 A panel Top View Photo 3 YET 250B 630 wireless receiver YET 205B 630 Photo 3 is a wireless receiver...

Страница 22: ...ure on rf 467 Press the YET 205B 630 BT key continuously and note that the LED E remains on Do not stop pressing the key and after about 5 seconds the blue LED E goes out indicating that the codes are...

Страница 23: ...ard installed and it has now been removed or is not working Check the card s connection with the panel If the error does not disappear in a few minutes contact your technician EXTENSION NO CONNECTED U...

Страница 24: ...ided or has any repairs or re setting done by a third party unless Olympia Electronics has fully agreed to them in writing Products that have been damaged can be returned to the premises of our compan...

Страница 25: ......

Страница 26: ......

Страница 27: ......

Страница 28: ......

Отзывы: