6.3 Entrance, exit, extra time settings 

 The  exit  time  must  be  sufficient  enough  for  the  user  to  leave  the  guarded  area 
before  the  system  arms.  Entry  time  should  be  enough  for  the  user  to  enter  the 
password for system disarm. It is advisable not to be marginal, in case of accidentally 
mistyped  passwords.  If  a  password  is  typed  from  a  wireless  keypad,  an  extra  5 
seconds  should  be  taken  care  of,  in  order  to  open  and  unlock  the  keypad.  It  is 
suggested that the input time is not less than 30 seconds when a wireless keyboard 
is used. As far as the extra time is concerned, it may be necessary for some zone to 
take extra time from the normal delay. For example, if some user needs to arm the 
system, but also needs to leave with the car from the garage, he could set the garage 
door zone as a "NEXT DELAY" zone and set its extra time by "TECHNICIAN MENU" 

 

"SETTINGS" 

 "EXTRA EXIT TIME". This additional time is also added when entering 

in an armed system. This extra time is rarely used. It is suggested that "NEXT DELAY" 
zones to be placed in a separate section. So some user could have one section with 
motion  sensors, one  with  magnetic  sensors  set to  "NEXT  DELAY"  and  one  with the 
other magnetic sensors. 
 

6.4 Zones bypass 

 forced arm 

 It is suggested that motion sensors have the following options during setup: Bypass 
=  "NO",  Forced  Arm  =  "YES".  In  that  way  the  user  can  arm  the  system,  bypassing 
them, but as soon as he leaves, the devices are able to give an alarm event. As far as 
magnetic  contacts  are  concerned,  they  are  usually  chosen  not  to  be  bypassed,  in 
order to prevent the system from arming and notify the user to secure those zones 
(close  an  open  window).  The  setting  for  this  is  Bypass  =  "NO"  and  Forced  Arm  = 
"NO". The keypad notifies the user one-by-one for zones that do not let the system 
arm. When all doors and windows are closed, the system starts the exit countdown 
without  having  to  re-enter  the  password.  If  a  user  wants  to  be  able  to  leave  a 
window  open  when  the  system  is  armed,  then  the  "FORCED  ARM"  option  for  this 
zone should be selected "YES". 
 

 

 

 

 

 

 

 

 

 

 

 

 

Содержание BS-468/A

Страница 1: ...WIRELESS BURGLAR ALARM SYSTEM BS 468 A QUICK INSTALLATION GUIDE...

Страница 2: ...S DEVICES 9 4 STARTING UP THE INSTALLED SYSTEM 10 4 1 SYSTEM CONFIGURATION 10 4 2 INSTALLATION COMPLETION 11 5 DEVICES INSTALLATION 11 5 1 Generals 11 5 2 Device s control operation 12 6 BASIC SYSTEM...

Страница 3: ...20 8 1 General 20 8 2 Installation 21 8 3 Codes registration procedure on rf 467 21 8 4 CODES DELETION PROCEDURE ON RF 467 22 9 System s app 22 9 1 Program for PC PC 468 A 22 9 2 Mobile app i olympia...

Страница 4: ...ion in addition to this manual please refer to the BS 468 A manual which is also enclosed within the kit as well as the instructions for the individual devices that are enclosed in the packaging of ea...

Страница 5: ...arm panel 1 PC BS 479 32 wireless zone expansion module for BS 468 A 1 PC RF 467 Remote control transmitter 433MHz for BS 468 BS 468 A panel 2 PCS YET205B 630 MODULE RECEIVER 433MHz RECEIVER MODULE 4...

Страница 6: ...lease refer to the user manual Section 3 6 Programming via computer B BS 466 A wired Keyboard The installation process through the wired keyboard is the same as that of the wireless keyboard in steps...

Страница 7: ...ncludes the devices detection and the second installs a wireless keypad When the BS 477 wireless keypad is installed the installation of the other devices can be completed by the keypad menu In order...

Страница 8: ...carried out by the menu NETWORK INSTALLATION 1 Press Go to MASTER OR TECH MENU By entering the technician code the user has now TECHNICIAN privileges 2 Go to WIRELESS NETWORK Press Choose NETWORK INST...

Страница 9: ...d every few seconds When refresh occurs 4 flashing dots appear on screen Prices above 30 means good signal 19 to 30 average signal and below 19 means low signal Beyond this value communication is poss...

Страница 10: ...IRELESS TAMPERS This feature allows the user to monitor in real time whether the tamper spring of each wireless device installed on the network is pressed or not The numbers displayed are the wireless...

Страница 11: ...all them on the system The installation procedure has come to its end You have set up an operating system and you know all the basic details to operate this system You can try an arm disarm test to ch...

Страница 12: ...D on the radar lights up and the keypad screen changes Let it be noted that radars turn on the LED on each activation only in the technician menu Be careful if a zone is in Disabled Off mode The senso...

Страница 13: ...added when entering in an armed system This extra time is rarely used It is suggested that NEXT DELAY zones to be placed in a separate section So some user could have one section with motion sensors...

Страница 14: ...Page 14 921468007_90_005 7 HANDLING THE SYSTEM WITH THE WIRELESS KEYPAD 7 1 Key Operations and Functions of the Wireless Keyboard...

Страница 15: ...EVICE ASSIGN ZONE NETWORK INSTALLATION DELETE SINGLE ZONE DELETE ALL ZONES RF COMM SUPERVISION WIRELESS TAMPERS WIRELESS SENSORS SIGNAL STRENGTH SIREN LED SETTING RF MASTER INFO 7 2 Basic Menu Passwor...

Страница 16: ...s locked Therefore once the device is switched on it is not necessary for the user to press first but can press for 5 seconds and send a panic alarm 7 4 Basic handling and settings The panel has 1 mai...

Страница 17: ...sarm each subsystem The arming of one subsystem does not affect the status armed disarmed of the other subsystems If during the arming procedure a zone is active then the keyboard shows the message Wh...

Страница 18: ...is means that it is disabled but would prevent the panel from arming if it was not disabled Selecting BYPASS W LESS ZONES we see The same applies for wireless zones The only difference is that the zon...

Страница 19: ...this is the 70th event of a total of 70 events With the up and down arrow keys 2 and 8 the user can see all the registered events The event memory has a capacity of 250 events and once filled the new...

Страница 20: ...alarm event only if the system is armed While the system is disarmed an information on the WIRELESS SENSORS menu screen is depicted If a wireless device does not communicate with the panel for a long...

Страница 21: ...tions A System arming B System disarming C Silent alarm D Panic alarm Photo 1 RF 467 Photo 2 BS 468 A panel Top View Photo 3 YET 250B 630 wireless receiver YET 205B 630 Photo 3 is a wireless receiver...

Страница 22: ...ure on rf 467 Press the YET 205B 630 BT key continuously and note that the LED E remains on Do not stop pressing the key and after about 5 seconds the blue LED E goes out indicating that the codes are...

Страница 23: ...ard installed and it has now been removed or is not working Check the card s connection with the panel If the error does not disappear in a few minutes contact your technician EXTENSION NO CONNECTED U...

Страница 24: ...ided or has any repairs or re setting done by a third party unless Olympia Electronics has fully agreed to them in writing Products that have been damaged can be returned to the premises of our compan...

Страница 25: ......

Страница 26: ......

Страница 27: ......

Страница 28: ......

Отзывы: