Issue 02 (2019-07-17)
27
BRE-I-5K14K
User Manual
5 Electrical Connections
Table 5-2
Cable description
No.
Cable
Type
Conductor
Cross-sectional
Area Range
Outer
Diameter
Source
1
DC input
power
cable
Standard PV cable in the
industry (recommended
model: PV1-F)
6 mm
2
4.5–7.8 mm
Prepared by
the customer
3
Signal cable Four-core outdoor shielded
twisted pair
1 mm
2
4–11 mm
Prepared by
the customer
4
AC
output
power
cable
Not using the PE
equipotential point at the
AC output port: two-core
(L and N) outdoor copper
cable
Using the PE equipotential
point at the AC output
port:
three-core (L, N, and PE)
outdoor copper cable
6 mm
2
10–21 mm
Prepared by
the customer
5
PE cable
Single-core outdoor copper
cable with an M6 OT
terminal
10 mm
2
N/A
Prepared by
the customer