Inputting the title

Title input box

Preset title select button

Serial number (3 digits)

Preset title register button

Keyboard

Input text from the on-screen keyboard

1.  Select an input mode and press the [MEAS/ENTER] joystick.

2.  Select the text button assigned to the letter you want to input and press the [MEAS/ENTER] joystick.

3.  Edit the work if necessary.

Select a preset title

1.  Select "PRESET" and press the [MEAS/ENTER] joystick.

2.  Select the preset title you want from the list and then press the [MEAS/ENTER] joystick.

3.  Repeat steps 1 and 2 to complete inputting a title.

General safety precautions

Observe the precautions described below when handling the instrument. Safety cannot be guaranteed when the 

instrument is used in way that are not specifically described.

Copied “General safety precautions” from “Safety precautions” in “MM1786”.

•  Never use this instrument for observation inside a human or animal cavity. 

Otherwise, death of the person or animal may result.

•  Never use the instrument in the following types of environments.

 - Where flammable atmospheres are present
 - Where metal dust or other dust is present

Otherwise, an explosion or fire may result.

•  Do not repair, disassemble, or modify the instrument. 

This instrument does not contain any user serviceable parts. Do not disassemble, modify or attempt to repair. User injury and/
or equipment damage can result. Olympus is not liable for any accidents or instrument damage that occurs as a result of repairs 
attempted by non-Olympus personnel. 
Contact Olympus for all repair and servicing.

•  Immediately stop using the instrument at the first sign of smoke, abnormal odor, abnormal noise, or any other abnormality. 

Even if operation of the instrument is still possible, turn off power.

•  Do not insert the insertion tube into an observation object that is in operation or conducting electricity. 

Otherwise the insertion tube may be damaged by being caught inside of the observation object, etc., or the insertion tube may 
touch the object, resulting in electric shock.

•  Before stowing the instrument in its carrying case, be sure to turn off power and remove the battery. Leaving the battery loaded 

during storage can cause it to become hot, causing the risk of fire.

DANGER

WARNING

•  Do not use this instrument in any environment (including strongly radioactive environments) that does not conform to the specified 

operating environment. 
Otherwise, unexpected accidents that may damage the insertion tube may result.

CAUTION

Содержание IPLEX RT

Страница 1: ...ttery Make sure battery is fully charged before setting up the videoscope Using the AC adapter Connect AC adapter to the main unit s AC adapter terminal making sure the cord is inserted securely Carefully read and understand the information and follow the instructions in the IPLEX RX RT in struction manual before using the instrument This operation manual is an introduction to the setup instrument...

Страница 2: ...dapter with the distal end so they are directly opposite each other carefully insert the optical adapter into the distal end Optical adapter Optical adapter main body Nut Optical adapter Second screw thread First screw thread Optical adapter positioning groove Connecting screw thread Distal end O ring 3 Turn the optical adapter nut clockwise until the first screw thread passes over the connecting ...

Страница 3: ...CAUTION Hold the handle of the main unit when transporting the main unit with the control unit affixed to the back The main unit may fall or the excessive force to the main unit may damage connections if you lift it by the control unit Back attachment For transport Handle Hanger Control unit holder rear Lock release button Control unit holder side Side attachment For observation The control unit c...

Страница 4: ...ght side of the main unit However this will be unbalanced and operation may be difficult when the control unit is attached to the side of the main unit Two strap rings are provided for attaching the strap when transporting the main unit Attach the strap to the two strap brackets and to one of the strap rings to do observations Using the strap Strap ring Strap bracket Not attached For transport For...

Страница 5: ...played in the USB connec tor 2 Press the VIEW button for at least two seconds to open the thumbnail screen Replaying the image 1 In the thumbnail screen move the thumbnail selection frame with the MEAS ENTER joystick to select the desired thumbnail image 2 After selecting the desired image with the thumbnail selection frame press the MEAS ENTER joystick to retrieve the selected image Recording the...

Страница 6: ...ll be recorded in images REC FUNCTION FRZ REC button image type setting Long pressing the FRZ REC button performs one of the following operations STILL MOVIE Live screen Records still image and movie Freeze screen Record still image only STILL ONLY Live screen Record still image only Freeze screen Record still image only SELECT OPTICAL ADAPTER Optical adapter selecting SELECT PDF FILE RX only PDF ...

Страница 7: ...are moved RENAME FILE Rename file Thumbnail screen only MEDIA FORMAT The USB flash drive formatting initialization Operations in the PDF file display screen RX only Main menu Sub menu Available settings MOVE PDF DOCUMENT Displays the top page Displays the previous page Pressing the BRT lever toward gives you the same effect Displays the next page Pressing the BRT lever toward gives you the same ef...

Страница 8: ...t repair disassemble or modify the instrument This instrument does not contain any user serviceable parts Do not disassemble modify or attempt to repair User injury and or equipment damage can result Olympus is not liable for any accidents or instrument damage that occurs as a result of repairs attempted by non Olympus personnel Contact Olympus for all repair and servicing Immediately stop using t...

Страница 9: ...Do not subject the distal end to severe impact or pulling Do not expose the angulation section to severe impact or bending Otherwise glass lenses and the precision components that make up the distal end and the angulation section might be damaged Never use the instrument without an optical adapter mounted Otherwise parts screws etc are easily subjected to deformation due to contact with hard objec...

Страница 10: ...nt where it is to be used and allow the condensation to dry before using it Do not cover the main unit with a plastic bag or other object during use If the inside of the instrument cannot be cooled the instrument damage may result Do not allow any liquids other than water saltwater machine oil or diesel oil come into contact with the insertion tube Otherwise the insertion tube may be damaged Be su...

Страница 11: ...arging After charging is complete always be sure to unplug the battery charger s power plug from the electrical outlet Immediately unplug the battery charger and stop using it at the first sign of heat generation abnormal odor abnormal noise smoke or any other abnormality Contact Olympus If the battery charger cannot complete battery charging in the specified recharging time stop trying to recharg...

Страница 12: ... temperatures recovers when the temperature rises to a normal level Contamination of battery electrodes with sweat or oil will cause contact failures When the battery is dirty wipe it clean with a dry cloth before use Use the battery correctly Otherwise battery fluid leakage overheating or damage may result Insert the batteries in the correct direction when replacing them A full charger will provi...

Отзывы: