Olimpus IPLEX RT Скачать руководство пользователя страница 10

- 10 -

•  When hanging the main unit from your neck by the shoulder strap, do not allow it to catch on other objects. Be careful that it does 

not choke you.

•  Do not allow metal or other foreign objects to enter the main unit through connectors or any other openings. 

Otherwise, a malfunction or electric shock may result.

•  Do not use the parts other than the insertion tube in water or clean them under running water. 

Water creates the risk of electric shock. The parts other than the insertion tube are designed for water resistant proof construc-
tion only if the battery cover and connector caps are closed completely. Do not use or store the instrument under the environment 
where it is submerged or wet.

•  Do not expose the LCD monitor to strong impact, strong pressure, or to scratching by a hard or pointed object. 

Otherwise, the LCD monitor might be cracked or scratched, or a damaged monitor could create the risk of personal injury.

•  Be careful to not pinch your hand or anything else when lowering the handle.

•  Never connect any other USB device or USB cable to the USB connector except for the USB flash drive provided as standard or 

USB Flash Drive recommended by Olympus.

•  Do not remove the battery or AC adapter while the system is running. 

Otherwise, recorded data may be damaged.

•  Do not remove the USB flash drive while recording or replaying the image. 

Otherwise, recorded data may be damaged or lost.

•  Do not continue to use the instrument when it is wet with condensation. 

Sudden temperatures changes such as those that occur when entering a warm room from the outside cold can cause condensa-
tion to form inside the instrument. Using the instrument while it is wet with condensation can cause malfunction. If condensation 
forms, leave the instrument in the environment where it is to be used and allow the condensation to dry before using it.

•  Do not cover the main unit with a plastic bag or other object during use. 

If the inside of the instrument cannot be cooled, the instrument damage may result.

•  Do not allow any liquids other than water, saltwater, machine oil, or diesel oil come into contact with the insertion tube. 

Otherwise, the insertion tube may be damaged.

•  Be sure to attach the O-ring to the insertion tube’s distal end before using the optical adapter.

Water getting into the area where the insertion tube and optical adapter join might cause malfunction or damage. Also note that an 
optical adapter by itself is not watertight.

•  If an optical adapter cannot be mounted or removed because the nut will not turn, stop using it.

Contact Olympus.

•  Never use the instrument while dirt or water is present in the optical adapter

Water tightness between the optical adapter and the distal end may be lost, or the optical adapter or the distal end may be dam-
aged.

•  Do not clean the optical adapter under running water.

Otherwise, the optical adapter might be damaged.

•  Do not bend the insertion tube to a radius that is less than its minimum bend radius (20 mm for the 4 mm type, 30 mm for the 6 

mm type) whenever operating the angulation section.

•  Note the following precautions whenever handing the battery cover, video connector cap, and AC adapter connector cap.

 - Do not open or close covers/caps while your hands are wet.
 - Do not open or close covers/caps in an area subject to high humidity and/or dust.
 - Close covers/caps before storing the instrument and when they are not in use.

•  Note the following precautions whenever removing the instrument from its carrying case.

 - Do not apply undue force when pulling the insertion tube from the slot in the cushion.
 - When removing the control unit or the main unit, do not lift it up by the universal cable or the insertion tube.

Otherwise, the instrument may be damaged.

This is a sentence for OPM.

This is the sentence for OPM.

This is the sentence for OPM.

This is the sentence for OPM.

This is the sentence for OPM.

CAUTION

Содержание IPLEX RT

Страница 1: ...ttery Make sure battery is fully charged before setting up the videoscope Using the AC adapter Connect AC adapter to the main unit s AC adapter terminal making sure the cord is inserted securely Carefully read and understand the information and follow the instructions in the IPLEX RX RT in struction manual before using the instrument This operation manual is an introduction to the setup instrument...

Страница 2: ...dapter with the distal end so they are directly opposite each other carefully insert the optical adapter into the distal end Optical adapter Optical adapter main body Nut Optical adapter Second screw thread First screw thread Optical adapter positioning groove Connecting screw thread Distal end O ring 3 Turn the optical adapter nut clockwise until the first screw thread passes over the connecting ...

Страница 3: ...CAUTION Hold the handle of the main unit when transporting the main unit with the control unit affixed to the back The main unit may fall or the excessive force to the main unit may damage connections if you lift it by the control unit Back attachment For transport Handle Hanger Control unit holder rear Lock release button Control unit holder side Side attachment For observation The control unit c...

Страница 4: ...ght side of the main unit However this will be unbalanced and operation may be difficult when the control unit is attached to the side of the main unit Two strap rings are provided for attaching the strap when transporting the main unit Attach the strap to the two strap brackets and to one of the strap rings to do observations Using the strap Strap ring Strap bracket Not attached For transport For...

Страница 5: ...played in the USB connec tor 2 Press the VIEW button for at least two seconds to open the thumbnail screen Replaying the image 1 In the thumbnail screen move the thumbnail selection frame with the MEAS ENTER joystick to select the desired thumbnail image 2 After selecting the desired image with the thumbnail selection frame press the MEAS ENTER joystick to retrieve the selected image Recording the...

Страница 6: ...ll be recorded in images REC FUNCTION FRZ REC button image type setting Long pressing the FRZ REC button performs one of the following operations STILL MOVIE Live screen Records still image and movie Freeze screen Record still image only STILL ONLY Live screen Record still image only Freeze screen Record still image only SELECT OPTICAL ADAPTER Optical adapter selecting SELECT PDF FILE RX only PDF ...

Страница 7: ...are moved RENAME FILE Rename file Thumbnail screen only MEDIA FORMAT The USB flash drive formatting initialization Operations in the PDF file display screen RX only Main menu Sub menu Available settings MOVE PDF DOCUMENT Displays the top page Displays the previous page Pressing the BRT lever toward gives you the same effect Displays the next page Pressing the BRT lever toward gives you the same ef...

Страница 8: ...t repair disassemble or modify the instrument This instrument does not contain any user serviceable parts Do not disassemble modify or attempt to repair User injury and or equipment damage can result Olympus is not liable for any accidents or instrument damage that occurs as a result of repairs attempted by non Olympus personnel Contact Olympus for all repair and servicing Immediately stop using t...

Страница 9: ...Do not subject the distal end to severe impact or pulling Do not expose the angulation section to severe impact or bending Otherwise glass lenses and the precision components that make up the distal end and the angulation section might be damaged Never use the instrument without an optical adapter mounted Otherwise parts screws etc are easily subjected to deformation due to contact with hard objec...

Страница 10: ...nt where it is to be used and allow the condensation to dry before using it Do not cover the main unit with a plastic bag or other object during use If the inside of the instrument cannot be cooled the instrument damage may result Do not allow any liquids other than water saltwater machine oil or diesel oil come into contact with the insertion tube Otherwise the insertion tube may be damaged Be su...

Страница 11: ...arging After charging is complete always be sure to unplug the battery charger s power plug from the electrical outlet Immediately unplug the battery charger and stop using it at the first sign of heat generation abnormal odor abnormal noise smoke or any other abnormality Contact Olympus If the battery charger cannot complete battery charging in the specified recharging time stop trying to recharg...

Страница 12: ... temperatures recovers when the temperature rises to a normal level Contamination of battery electrodes with sweat or oil will cause contact failures When the battery is dirty wipe it clean with a dry cloth before use Use the battery correctly Otherwise battery fluid leakage overheating or damage may result Insert the batteries in the correct direction when replacing them A full charger will provi...

Отзывы: