background image

- 4 -

1.  While pressing the shoulder strap hook lever, attach 

the hook to a main unit strap ring or the strap bracket.

2.  During observation, attach the shoulder strap 

so that the side with the two connections is 
on the left side of the main unit, as shown 
in the figure right. The two connections can 
also be attached to the right side of the main 
unit. However, this will be unbalanced and 
operation may be difficult when the control 
unit is attached to the side of the main unit.

Two strap rings are provided for attaching the strap 
when transporting the main unit. Attach the strap to 
the two strap brackets and to one of the strap rings to 
do observations.

Using the strap

Strap ring

Strap bracket

Not attached

For transport

For observation

3.  Use the shoulder strap to hang the IPLEX RX/RT (main unit) 

from your shoulder.

For transport

For observation

Содержание IPLEX RT

Страница 1: ...ttery Make sure battery is fully charged before setting up the videoscope Using the AC adapter Connect AC adapter to the main unit s AC adapter terminal making sure the cord is inserted securely Carefully read and understand the information and follow the instructions in the IPLEX RX RT in struction manual before using the instrument This operation manual is an introduction to the setup instrument...

Страница 2: ...dapter with the distal end so they are directly opposite each other carefully insert the optical adapter into the distal end Optical adapter Optical adapter main body Nut Optical adapter Second screw thread First screw thread Optical adapter positioning groove Connecting screw thread Distal end O ring 3 Turn the optical adapter nut clockwise until the first screw thread passes over the connecting ...

Страница 3: ...CAUTION Hold the handle of the main unit when transporting the main unit with the control unit affixed to the back The main unit may fall or the excessive force to the main unit may damage connections if you lift it by the control unit Back attachment For transport Handle Hanger Control unit holder rear Lock release button Control unit holder side Side attachment For observation The control unit c...

Страница 4: ...ght side of the main unit However this will be unbalanced and operation may be difficult when the control unit is attached to the side of the main unit Two strap rings are provided for attaching the strap when transporting the main unit Attach the strap to the two strap brackets and to one of the strap rings to do observations Using the strap Strap ring Strap bracket Not attached For transport For...

Страница 5: ...played in the USB connec tor 2 Press the VIEW button for at least two seconds to open the thumbnail screen Replaying the image 1 In the thumbnail screen move the thumbnail selection frame with the MEAS ENTER joystick to select the desired thumbnail image 2 After selecting the desired image with the thumbnail selection frame press the MEAS ENTER joystick to retrieve the selected image Recording the...

Страница 6: ...ll be recorded in images REC FUNCTION FRZ REC button image type setting Long pressing the FRZ REC button performs one of the following operations STILL MOVIE Live screen Records still image and movie Freeze screen Record still image only STILL ONLY Live screen Record still image only Freeze screen Record still image only SELECT OPTICAL ADAPTER Optical adapter selecting SELECT PDF FILE RX only PDF ...

Страница 7: ...are moved RENAME FILE Rename file Thumbnail screen only MEDIA FORMAT The USB flash drive formatting initialization Operations in the PDF file display screen RX only Main menu Sub menu Available settings MOVE PDF DOCUMENT Displays the top page Displays the previous page Pressing the BRT lever toward gives you the same effect Displays the next page Pressing the BRT lever toward gives you the same ef...

Страница 8: ...t repair disassemble or modify the instrument This instrument does not contain any user serviceable parts Do not disassemble modify or attempt to repair User injury and or equipment damage can result Olympus is not liable for any accidents or instrument damage that occurs as a result of repairs attempted by non Olympus personnel Contact Olympus for all repair and servicing Immediately stop using t...

Страница 9: ...Do not subject the distal end to severe impact or pulling Do not expose the angulation section to severe impact or bending Otherwise glass lenses and the precision components that make up the distal end and the angulation section might be damaged Never use the instrument without an optical adapter mounted Otherwise parts screws etc are easily subjected to deformation due to contact with hard objec...

Страница 10: ...nt where it is to be used and allow the condensation to dry before using it Do not cover the main unit with a plastic bag or other object during use If the inside of the instrument cannot be cooled the instrument damage may result Do not allow any liquids other than water saltwater machine oil or diesel oil come into contact with the insertion tube Otherwise the insertion tube may be damaged Be su...

Страница 11: ...arging After charging is complete always be sure to unplug the battery charger s power plug from the electrical outlet Immediately unplug the battery charger and stop using it at the first sign of heat generation abnormal odor abnormal noise smoke or any other abnormality Contact Olympus If the battery charger cannot complete battery charging in the specified recharging time stop trying to recharg...

Страница 12: ... temperatures recovers when the temperature rises to a normal level Contamination of battery electrodes with sweat or oil will cause contact failures When the battery is dirty wipe it clean with a dry cloth before use Use the battery correctly Otherwise battery fluid leakage overheating or damage may result Insert the batteries in the correct direction when replacing them A full charger will provi...