12 HP Model# 01925

INVERTER

Содержание Maestro Pro 01925

Страница 1: ...12 HP Model 01925 INVERTER ...

Страница 2: ...nimum spaces indicated in figure 2 2 MAIN INDEX Descriptive Illustrations The illustrations provided on pages 8 through 18 of this manual are intended to identify components and aid in the installation process 0 WARNINGS 4 0 1 General information 4 0 2 SYmBolS 4 0 2 1 eDITORIALPICTOGRAMS 5 0 3 General WarninGS 5 7 1 DESCRIPTION OF THE UNIT 18 1 1 liSt of tHe ComPonentS SUPPlieD 18 1 2 StoraGe 19 1...

Страница 3: ...y only models fitted with heating pump 33 3 6 9 Checking airflow direction 33 3 6 10 Checking fan speed 33 3 6 11 Silent key 34 3 6 12 timer setting 34 3 6 13 timer and clock setting 34 3 6 14 timer setting 35 3 6 15 timer activation and deactivation 35 3 6 16 reset of all the remote control functions 35 3 6 17 managing the unit if the remote control is not available 36 3 7 reCommenDationS for ene...

Страница 4: ...hem may result in danger of injury to the operators loss of the warranty refusal of liability by the manufacturer Raised hand Refers to actions that absolutely must not be performed DANGER OF HIGH VOLTAGE Signals to the personnel that the operation described could cause electrocution if not performed according to the safety rules GENERIC DANGER Informs that if the operation is not carried out in c...

Страница 5: ...nder pressure as well as powered parts As such the installation first startup and subsequent maintenance should be carried out exclusively by qualified personnel 6 Failing to comply with the instructions contained in this manual and using the unit with temperatures exceeding the permissible temperature range will invalidate the warranty 7 Routine maintenance of the filters and general external cle...

Страница 6: ... an Olimpia Splendid USA Service Center or a licensed contractor in you area 17 Do not let the unit run for extended periods if a door or windor to the outside is open Moisture may condense resulting in wet or damaged furniture or other items in the space 18 To avoid the potential for electric shock or damaging the unit do not unplug the power supply during operation or store heaters or other appl...

Страница 7: ...ocal and national A Maestro Pro Unit B Remote control B1 Batteries for remote control Two AAA required C Use and maintenance booklet D Strips of adhesive isolating tape E Air inlet and outlet grids including chains F Internal flanges G Sheet for wall pipes H Screws and anchor bolts L Mounting Brackets M Paper template to make holes N Condensation drain pipe O Purifying filter green P Active carbon...

Страница 8: ...IT ISTRUZIONI PER USO E MANUTENZIONE INVERTER min 3 2 81 mm min 2 4 61 mm min 4 102 mm 1 2 D E m P G O h N L F A B B1 C 8 min 2 4 61 mm ...

Страница 9: ...m Y 4 5 3 9 ...

Страница 10: ...min 12 300mm 8 9 B N ø 3 8 mm 6 h h 7 6 10 ...

Страница 11: ...G G 10 12 11 G F D F G 13 14 11 8 203mm 6 5 162 mm 5 1 130mm Note The 8 203 mm diameter hole is prefered to achieve the best operating efficiency Both intake and exhaust holes must be the same size ...

Страница 12: ...15 19 17 16 20 18 F E E E 12 1 4 6 mm ...

Страница 13: ...22 23 A A B B 21 W 13 ...

Страница 14: ...h h L L 26 28 24 29 25 L L 27 3 3 3a 3a 1 1 1a 1a 1a 1b 1b 1b 1a A A A A A 1c 14 ...

Страница 15: ...34 32 33 35 J1 J2 J1 J2 X3 X4 30 31 X1 X2 X2 15 ...

Страница 16: ...41 39 40 F 3 F F2 F1 F F2 F2 F1 F1 26 8m 38 36 37 10 7 16 3 2 80mm ...

Страница 17: ...43 3 3 42 F 44 45 6 6a 17 min 5qts 4 8L ...

Страница 18: ... Battery for remote control quantity 2 aaa t ype x 1 5V C Use and maintenance booklets warranty D Strip of adhesive isolating tape x 2 E airinletandoutletexternalgridsincludingchainsand kit for installing the grids x 2 F Internal flanges x 2 G Sheet for wall pipes x 2 H Kit of screws and anchor bolts L Wall anchoring bracket x 2 M Paper template to make holes N Condensation drain pipe O Purifying ...

Страница 19: ...attention when unpacking and installing the equipment d Sharp parts can cause injury Pay particular attention to the edges of the unit along with the fins of the condenser and evaporator No claims for damage will be considered if not submitted within 3 days of delivery In the unlikely event the unit needs to be returned or repaired it s recommended to keep the packaging for the duration of the war...

Страница 20: ...st be equipped with a code compliant grounding system co to obtain the best operating performance and prevent faults or hazardous conditions the position of indoor unit installation must meet the following requirements 2 3 CHOOSING THE POSITION OF THE UNIT to obtain the best operating performance and prevent faults or hazardous conditions the position of indoor unit installation must meet the foll...

Страница 21: ...or brick walls are special drill bits called core borers with very high twisting torque and adjustable rotating speed depending on the diameter of the hole to be drilled 21 Drill the foregoing holes tilted slightly downwards to prevent water from being fed back through the ducts fig 5 Most of the removed material is expelled outwards therefore make sure that it does not hit any person or object wh...

Страница 22: ...ondensate to flow out from the internal tray For cooling only units a connect line condensate line if the unit will be operated at outdoor temperatures lower than 74ºF 23ºC Since condensate drains by gravity there must be a minimum slope of at least 1 4 6 4mm per foot 3m Use a rigid or flexible tube having an inside diameter of at least 5 8 16mm If the line empties into a sewerage system install a...

Страница 23: ...ype of installation break the rectangular pre cut shown in fig 23 and use a suction grille of a size suitable for the suction channel 23 To position the external grills proceed as follows a Apply the seal F to the wall flange D ensuring it lines up with the outer edge of the flange as indicated in the figure 13 b Fix the two flanges using two 1 4 6mm pegs and check that the two mounting holes are ...

Страница 24: ...is powered through a socket that is compatible with the plug supplied Replacement of the power cord must be done by a qualified technician On the power supply line of the unit there must be an adequate omni polar disconnect device that complies with the national installation regulations The installer must check that the electrical power supply is equipped with a ground wire having adequate protect...

Страница 25: ...tract the switch towards the exterior of the switchgear fig 34 A g Unscrew cable clamp J1 fig 33 h Unscrew the cable s locking screws on the terminal board J2 fig 33 i Remove the old cable then install the new one by reversing the steps shown above l Install then tighten the three wires in the cable in the terminal board J2 fig 34 m Lock the cable with the clamp J1 fig 34 n Close the switchgear o ...

Страница 26: ...unit restores its previous operation condition ENERGY BOOST has no effect when the unit is in fan dehumidification or automatic modes This operation must be performed by the installer or similarly qualified service technician as per local state and or national requirements To prevent the risk of an electric shock unplug or de energize the unit before making the electrical connections or any mainte...

Страница 27: ...sconnect it from the power mains Call the nearest service center or local licensed contractor When the unit is heating it has to periodically eliminate ice or frost that could form on the coil While in defrost mode the unit keeps running but does not heat the room Depending on ambient conditions the lenth of time the unit will be in defrost will vary from 3 to10 minutes Clean the air filter as oft...

Страница 28: ...f tap for more than 2 seconds to select Fan Only cooling or heating operation modes Prolonged press to enable parameters setting if in Stand by mode and t o be pressed simultaneously for at least 5 seconds to enable disable the keypad lock function Others IR infrared receiver B Buzzer and MODE t o be pressed simultaneously and for an extended period of time at least 5 seconds to reset the dirty fi...

Страница 29: ...fluorescent lights may also have the potential to interfere with transmissions between remote control and the unit In case of prolonged disuse of the remote control the batteries should be removed The remote control display goes off after a few seconds of non use to reactivate press any key Maximum distance from the remote to the unit must be no more than 33 10m fig 37 29 OPERATING CONDITIONS DISP...

Страница 30: ...horoughly with clean water Do not use the remote control with leaky batteries The chemical products contained in batteries can cause burns or other health risks 3 4 1 Installing of batteries To insert the batteries correctly fig 35 a Remove the battery compartment cover b Insert the batteries into the r compartment Check the polarity of the batteries as indicated on the bottom of the compartment c...

Страница 31: ...ing setting B10 activation deactivation of the functions programming 1 programming 2 B11 activation deactivationofthedisplayonboardofthemachine switching on B12 Desired temperature unit selection ºC ºf B13 activation deactivation of the report console display B1 B2 B3 B4 B9 B10 B5 B13 B6 B7 B8 B12 B11 E D9 D1 D20 D19 D18 D16 D14 D2 D3 D5 D7 D4 D6 D8 D17 D15 D10 D11 D12 D13 3 5 2 Description of the...

Страница 32: ...its a beep when it receives a command The maximum distance from the unit to the remote is 33 10m with fully charged batteries 32 3 6 4 Operation in Cooling mode only When used in this mode the unit dehumidifies and cools the room To activate this mode press several times the key B5 on the remote control until when the symbol D2 appears on its display In this run mode the required temperature and f...

Страница 33: ... mode only heat pump models When the unit operates in heating the refrigeration system is in reverse cooling mode To activate Press the B5 key on the remote control until the D1 symbol appears on its display In this mode the required temperature and fan speed can be set by the user After a maximum of 3 minutes the compressor will start and the unit begins heating the space The moving deflector fla...

Страница 34: ...en the minutes symbol m D11 appears on the display d Set the minutes with keys B6 and B7 e Press the B9 key to save the time and proceed with the timer programming 34 3 6 11 SILENT Night key To activate this mode first select the desired operational mode and user setpoint Then press the B3 key on the remote control The D14 symbol will appear on the display The activation of Silent night mode resul...

Страница 35: ...The length of time is selectable in 30 minute increments g Press key B9 Set timer again the 2 D6 Deactivation time of program 2 and the OFF symbol D7 appear on the display h Use keys B6 and B7 to increase or decrease the length of time the unit is deactivated The length of time is selectable in 30 minute increments i To return to normal operation mode press the B9 key multiple times until all the ...

Страница 36: ...led closed avoid the sun s rays penetrating freely into the room we recommend using curtains or lowering blinds or closing the shutters Do not obstruct the supply or return air as it can result in redused capacity and or unit failure 4 1 2 Cleaning the air filter To ensure effective internal air filtration and satisfactory operation of unit the air filter has to be cleaned periodically The air fil...

Страница 37: ...e any traces of dust or dirt during assembly fig 24 It s also recommended to explain system operation to the end user show them how to remove and clean the air filters then make them familiar with the installation and operating instructions 4 2 2 Condensation water drainage in case of emergency Should the condensation disposal system get clogged or stop draining the unit stops and displays alarm c...

Страница 38: ...E external air temperature probe faulty 1 Condenser temperature probe faulty 2 inlet temperature probe faulty 3 Compressor current protection 4 Communication error 5 Power line overcurrent 6 Compressor current protection not suitable 7 Power board DC voltage problem 8 Current anomaly 9 Condenser temperature too high 10 UiPm protection 11 eeProm error 12 inlet temperature too high 13 room temperatu...

Страница 39: ...ure setting Setthetemperaturecorrectly Consul the Usingtheremotecontrol chapter for the procedure The air filter is dirty Clean the air filter the doors or windows are open Close the doors or windows the air inlet or outlet vents of the indoor or outdoor units are blocked first remove the obstructions and then re start the unit the compressor 3 minute protection has activated Wait The unit works b...

Страница 40: ... Minimum Operating Temperature in Cooling Mode F C DB 64 F 18 C Maximum Operating Temperature in Heating Mode F C DB 81 F 27 C Minimum Operating Temperature in Heating Mode F C Outdoor Temperature Maximum Operating Temperature in Cooling Mode F C DB 109 F 43 C WB 90 F 32 C Minimum Operating Temperature in Cooling Mode F C DB 14 F 10 C Maximum Operating Temperature in Heating Mode F C DB 75 F 24 C ...

Страница 41: ...plendidusa com must be submitted along with the warranty claim if requesting a replacement unit due to compressor failure Claims submitted with a missing or incomplete data sheet are subject to delays and or warranty rejection DISCLAIMER OF IMPLIED WARRANTIES LIMITATION OF REMEDIES CUSTOMER S SOLE AND EXCLUSIVE REMEDY UNDER THIS LIMITED WARRANTY SHALL BE PRODUCT REPAIR OR REPLACEMENT AS PROVIDED H...

Страница 42: ... Prior to Starting the unit verify Supply Voltage to the unit _______ Install batteries in Remote Control Start Unit to verify operation and record requested values below The following values are to be recorded after the unit has run a minimum of 10 minutes to insure stabilized operation at high airflow and full compressor operation Cooling Mode return air Dbº_____ Wbº_____ Supply Air Dbº_____ Wbº...