ENGLISH
EN - 12
- The value of the first code “
X
” is “
0
”; press the temperature setting keys
and
to adjust the value of the second code;
- After having set the value of the second code, press the
key to save and pass to the next
code;
- When reaching code “
6
”, press the
key to exit parameters setting.
4.
The remote control is factory-set. Change the parameters only is particular operating conditions are
required (in particular the frequency of cleaning the air filter).
First
code
Function
Second code
0
1
2
3
4
0
Cool Only/Cool-Heat
Selection
Cool-Heat
(default)
Cool Only
/
/
/
1
Setting
the communication
address of the internal
unit
YES
(default)
NO
/
/
/
2
Switch-off memory
YES
(default)
NO
/
/
/
3
Air filter cleaning interval
Function
disabled
1250
hours
2500
hours
(default)
5000
10000
5
Remote reception
function
YES
(default)
NO
/
/
/
6
Temperature selection
°C - °F
Centigrade °C
(default)
Fahrenheit
/
/
/
2 - TECHNICAL DATA AND FUNCTIONS
2.1 - TECHNICAL DATA
Input voltage
DC +5V
Environment temperature
-5 ~ 43°C
Environmental humidity
RH40% ~ RH90%
2.2 - FUNCTIONS
Main features of the remote control:
1.
Connect the remote control to the appliance via the four ports A, B, C, D (fig. 2).
2.
Set the operating mode via remote control keys.
3.
Remote control with LCD.
4.
Remote control fitted with timer function.