8. PROBLEMS, POSSIBLE CAUSES AND SOLUTIONS  

 

Caution! These operations must be carried out by specialized personnel. 
Before performing any service operation, be sure that the unit is disconnected from the elctric power supply. 
 

PROBLEM 

POSSIBLE CAUSE 

SOLUTION 

The electropump does not 
pump  water.  The  motor 
does not  run. 
 

- No power. 
- Motor protection tripped. 
- Demaged capacitator. 
- Shaft blocked. 
-  A  solid  object  is  blocking  the 
impeller. 

- Check the voltage. 
- Verify the cause and reset the switch. If 
the  thermal  circuit  breaker  has  tripped 
wait for the system to cool down. 
- Replace the capacitator. 
-  Verify  the  cause  and  unblock  the 
electropump. 
-  Disassemble  the  hydraulic  part  and 
verify if the impellers rotate freely. 
 

The  motor  runs  but  the 
electropump  does  not 
pump water. 
 

- The pump is sucking air. 
-  The  pump  rotates  in  the  wrong 
direction (Three-phase pumps). 
- Suction grid blocked. 
- Check valve blocked. 
- Low voltage. 
 

- Make sure that the joints are air-tight. 
Check  that  the  liquid  has  not  dropped 
below the minimum level. 
- Invert the electric phase connection of 
rotation. 
- Clean the suction grid. 
- Clean or replace valve. 
- Use electric cables of larger diameter. 

The  electropump  stops 
after  running  for  a  short 
period  of  time  because 
one  of  the  termal  motor 
circuit breaker trips. 
 

-  The  power  supply  does  not 
correspond  with  the  data  on  the 
nameplate. 
- The pump has run without liquid. 
 

- Check the voltage on the power supply 
cables leads. 
-  If  the  pump  is  equipped  with  a  float 
switch,  verify  if  this  is  functioning 
working  it  manualy.  Reestablish  the 
water level before restart the pump. 

If in spite of carring out the above operations the problem still persists contact the nearest service centre. 
 

 

 

Содержание Aqualiju AC4.110.1A

Страница 1: ...NL DE Aqualiju FR IT ES EN PT OLIJU INSTRUCTIONS Installation and operation instructions The realiability is our brand...

Страница 2: ...ou transport it 4 INSTALLATION Never use the electric power cable to suspend the pump Avoid dry running Install the pump only vertically 4 1 PUMP INSTALLATION IN THE RESTING POSITION TANKS The pump ca...

Страница 3: ...odes to prevent the pump against dry runnig frequency protetor against phase lack Thermal protector gauged for the motor mains voltage 6 STARTING Never run the pump dry not even for a short trial run...

Страница 4: ...ctropump does not pump water The pump is sucking air The pump rotates in the wrong direction Three phase pumps Suction grid blocked Check valve blocked Low voltage Make sure that the joints are air ti...

Страница 5: ...bomba sempre que a transporte 4 INSTALA O Nunca use o cabo el ctrico para suspender a bomba Evite o funcionamento em seco da electrobomba Instale a bomba apenas verticalmente 4 1 INSTALA O DA BOMBA E...

Страница 6: ...a protec o contra a falta de gua um rel de frequ ncia contra a falta de fase um rel t rmico calibrado para a corrente do motor 6 ARRANQUE Nunca ligar a bomba em seco nem mesmo por um curto per odo de...

Страница 7: ...lsores giram livremente O motor arranca mas a electrobomba n o fornece gua A electrobomba absorve ar Sentido de rota o errado trif sica Filtro de aspira o obstru do V lvula de reten o bloqueada Tens o...

Страница 8: ...ombear liquidos peligrosos o inflamables Esta bomba no es para uso port til Apague la bomba siempre que el transporte 4 INSTALACION No usar el cable electrico para suspender la electrobomba Evitar el...

Страница 9: ...a la falta de fase un rel t rmico calibrado para la corriente del motor 6 ARRANQUE Nunca se debe realizar en seco Al menos se debera sumergir a una profundidad de 200mm No se debe retirar la electrobo...

Страница 10: ...a su enfriamento Substituir condensador Desbloquear parte hidraulica y comprobar que giran libremente El motor funciona pero la electro bomba no saca agua Mal sentido de giro Filtro aspiracion obstrui...

Страница 11: ...mpe ne doit pas tre utilis e avec des liquides agressifs dangereux ou inflammables Cette pompe est pr vue pour tre utilis e de mani re fixe D brancher la pompe chaque fois qu elle doit tre transport e...

Страница 12: ...rm diaire d un coffret il comportera Une protection manque d eau avec ventuelles sondes ou flotteur Une protection manque de phase Une protection thermique du moteur adapt e la tension du r seau 6 D M...

Страница 13: ...eur tourne mais la pompe ne d livre pas d eau La pompe aspire de l air La pompe tourne dans le mauvais sens Triphas La cr pine est colmat e Le clapet est bloqu Tension trop basse Assurez vous qu il n...

Страница 14: ...ttivare l alimentazione elettrica della pompa ogni volta che deve essere trasportata 4 INSTALLAZIONE Non usare mai il cavo elettrico per sollevare la pompa Evitare il funzionamento a secco dell elettr...

Страница 15: ...ifomimento di elettricit attraverso un quadro equipaggiato con Dispositivo elettronico che comanda le sonde per un perfetto controllo di livello dell acqua evitando il funzionamento a secco de1la pomp...

Страница 16: ...pomba non pompa acqua La pompa sta aspirando aria La pompa ruota nella direzione sbagliata pompe trifasi Griglia di aspirazione ostruita Valvola di controllo bloccata Bassa tensione Accertarsi che le...

Страница 17: ...niet gebruikt worden met agresssieve gevaarlijke of ontvlambare vloeistoffen De pompen zijn enkel voorzien voor vaste opstellingen Pomp uitschakelen voor alle verplaatsingen 4 INSTALLATIE De pomp nie...

Страница 18: ...kelaar Een fasegebrek beveiliging Een aangepaste thermische beveiliging met snelle uitschakeling 6 OPSTARTEN Nooit de pomp zonder water laten draaien zelfs niet voor een korte periode De pomp moet eer...

Страница 19: ...en dat de waaiers losdraaien De motor draait maar de pomp geeft geen water De pomp zuigt lucht De pomp draait in de verkeerde richting Driefasig De korf is dicht De terugslagklep zit vast Te lage span...

Страница 20: ...icht verwendet werden um gef hrliche oder brennbare Fl ssigkeiten f rdern Diese Pumpe ist nicht f r den mobilen Einsatz gedacht Schalten Sie diese Pumpe jedes Mal aus wenn Sie die Pumpe transportieren...

Страница 21: ...nuten 5 4 AQUALIJU 400V Drehstrompumpen m ssen mit einer Pumpensteuerung und Motorschutz ber und Unterlast und Phasenausfallschutz betrieben werden Trockenlaufschutz mit Elektroden oder ber Motorstrom...

Страница 22: ...saugt Luft Die Pumpe dreht sich in die falsche Richtung Drehstrom Pumpen Ansauggitter blockiert R ckschlagventil blockiert Spannung zu niedrig Stellen Sie sicher dass die Abdichtungen luftdicht sind...

Страница 23: ...23...

Страница 24: ...e d claration sont conformes la directive 2006 42 CE EN ISO 12100 EN 60335 1 EN 60335 2 41 2004 108 CE DICHIARAZIONE DI CONFORMITA I prodotti su elencati sono conformi alle direttiva 2006 42 CE EN ISO...

Отзывы: