69
Ethernet MCA 10/100 Adapter v. 1.0, P/N: 710001414
Driver Messages
OCE3XODI-DOS-20 This version of the statistics table is not supported.
See the Novell NetWare documentation.
OCE3XODI-DOS-21 A program hooked Int 2F after the OCE3XODI MLID.
IPXODI, NETX or VLM are probably loaded. Unload these program before unloading OCE3XODI.
Errors specific to the OCE3XODI.COM DOS ODI Driver
OCE3XODI-DOS-51 This driver only supports AT or MCA class machines.
The driver has detected that your PC does not conform with the AT or MCA specifications.
Contact your place of purchase.
OCE3XODI-DOS-52 Adapter not found.
Check that the OC-2335 is properly inserted. If this does not solve the problem, check that all software
components are properly installed. Then run the DIAG program.
Contact your place of purchase if the error condition persists.
OCE3XODI-DOS-53 Error accessing EEPROM on adapter.
The driver has located the OC-2335 adapter in the system but cannot access its EEPROM. Check that the
adapter is properly inserted. If this does not solve the problem, check that all software components are
properly installed. Then run the DIAG program.
Contact your place of purchase if the error condition persists.
OCE3XODI-DOS-54 Adapter failed Built In Self Test.
Check that the OC-2335 is properly inserted. If this does not solve the problem, check that all software
components are properly installed. Then run the DIAG program.
Contact your place of purchase if the error condition persists.
OCE3XODI-DOS-55 The Media could not be selected.
The media type selected with DIAG or via keywords cannot be selected. Remove any keywords from the
NET.CFG file and try again. If this does not solve the problem, then run the DIAG program.
OCE3XODI-DOS-56 Adapter must be inserted in a 16 bit slot.
Move your adapter to a 16 bit slot.
OCE3XODI-DOS-57 Invalid Burned In Address or checksum.
Run the OC-2335 DIAG program.
OCE3XODI-DOS-59 I/O port address in NET.CFG is invalid.
Locate and fix the error in NET.CFG See also the netware documentation.
OCE3XODI-DOS-72 INT parameter read from adapter is invalid.
Check that the OC-2335 is properly inserted. Then run the DIAG program.
Contact your place of purchase if the error condition persists.
OCE3XODI-DOS-80 The Media could not be AUTO detected.
The media could not be automatically detected. Check that the cable is properly attached. Then run the
DIAG program.
OCE3XODI-DOS-81 Cable appears to be disconnected.
Check that the cable is connected. If this does not solve the problem, then run the DIAG program.
Invalid SPEED keyword in NET.CFG
Values supported:
AUTO - Automatic network speed detection
10 - Force 10 Mbps
10 - Force 100 Mbps
Action: Use a legal value for SPEED. Default: Auto.
Invalid DUPLEX keyword in NET.CFG.
Values supported:
AUTO - Automatic media detector
FULL - Force Full duplex
HALF - Force Half duplex
Action: Use a legal value for DUPLEX. Default: AUTO.
Содержание Ethernet MCA 10/100 Adapter
Страница 1: ...Guide to Operations Ethernet MCA 10 100 Adapter OC 2920 1 0...
Страница 2: ...Ethernet MCA 10 100 Adapter v 1 0 P N 710001414 Ethernet MCA 10 100 Adapter Guide to Operations...
Страница 11: ...4 Ethernet MCA 10 100 Adapter v 1 0 P N 710001414 Introduction...
Страница 13: ...6 Ethernet MCA 10 100 Adapter v 1 0 P N 710001414 Installation Overview...
Страница 17: ...10 Ethernet MCA 10 100 Adapter v 1 0 P N 710001414 Hardware Installation...
Страница 19: ...12 Ethernet MCA 10 100 Adapter v 1 0 P N 710001414 Windows 95 Express Installation...
Страница 61: ...54 Ethernet MCA 10 100 Adapter v 1 0 P N 710001414 Troubleshooting...
Страница 67: ...60 Ethernet MCA 10 100 Adapter v 1 0 P N 710001414 Contacting Technical Support...
Страница 69: ...62 Ethernet MCA 10 100 Adapter v 1 0 P N 710001414 System Requirements...
Страница 81: ...74 Ethernet MCA 10 100 Adapter v 1 0 P N 710001414 Driver Messages...
Страница 85: ...78 Ethernet MCA 10 100 Adapter v 1 0 P N 710001414 Technical Information Status LEDs Figure 9 Status LEDs...