8.
Troubleshooting
Table 5 Troubleshooting
Problem
Method
LiDAR fails to
scan
Verify whether the power supply is properly connected
Verify whether the power voltage meets 12~32VDC
Please contact OLEI if the above conditions are normal.
LiDAR scan
produces no data
Verify whether the network connection is normal
Verify whether the IP settings on the data receiver are correct.
Try to use third-party data scraping software to verify whether data could
be obtained normally
Verify whether only one LiDAR software is enabled.
Verify whether firewall of the data receiver is disabled or if there are
other security software or processes blocking data transmission.
Please contact OLEI if the above conditions are normal.
LiDAR can not
respond when
obstacle is detected
Check if the software configuration is correct and if the
configuration file is successfully downloaded
.
Verify whether the wiring at the I/O port is correct.
When the I/O port is not
not connected
, Bank 0 is the effective field
group by default.
The I/O port is only connected to VCC and GND. When other PIN are
not connected, Bank 15 is considered to be the valid field group by
default.
Please contact OLEI if the above conditions are all normal.