Antibacterial cotton, HEPA filter (approximately once every two months)

-Place the filter in a ventilated area, this will allow harmful gasses 
 and germs to dissipate. Do not place under too much sun exposure.
-Do not use water to clean this filter.

-When you hear the machine produce 
 a creaking sound, use a #1 or #2 
 paintbrush as a cleaning tool. Insert 
 the brush from the ventilation window 
 above the anion emission head. 
 Regularly clean the dust all around 
 the emission head.

4. Anion producer cleaning and maintenance.

Paintbrush

15

14

5. Particulate sensor (approximately once every two months).

Wipe the lens with a dry cotton swab periodically to remove any dirt. (Moisture or tobacco smoke residue 
may cause it to no longer work properly). First remove the particulate sensor cover, use a dry cotton swab 
to wipe the lens.
-Do not insert the cotton swab into any area other than the lens.
-Be sure to unplug the power cord.
-If you are unable to see clearly, please use a light.

Cotton Swab

Friendly Reminders:

-Before cleaning and maintenance, unplug the power cord.
-Do not operate the machine in absence of a filter. It will not be able to remove the dust. Dust taken into 
 the machine may cause malfunction.
-When not using the machine for a long period of time, please unplug it. Power is also consumed while 
 in standby mode.
-You may need to replace filters sooner depending on where and how you use the appliance (such as a 
 household with a large smoking population or areas with higher air pollution). Replace the filter if 
 filtration is not noticeable.

1PC

Packaged Items

Body

Remote Control

Filters 

Instructional Manual

1PC

3PCS

1PC

Humidification

 

Mesh

1PC

Содержание K08

Страница 1: ...User Manual Air Purifier Fresh Air Healthy Life Please read this manual completely before using this product...

Страница 2: ...on of air purification devices If any questions arise from use please consult this manual If it is in accordance with the warranty we kindly welcome you to contact us with the address and phone number...

Страница 3: ...istics Antibacterial Cotton Filter The antibacterial filter is a precision filter trapping particles with a diameter of 5 microns At the same time there is an antibacterial agent added into the filter...

Страница 4: ...ove the filter C Take the filter out of the packaging Make sure to remove plastic bag off the filter before use The machine will not run if the front panel is uncovered Prepare for humidification 1 Pu...

Страница 5: ...320 hours the indicator light on the panel will flash to inform users to clean the filter No 1 After cleaning press the RESET button for 5 seconds then the light will stop flashing After every 1500 ho...

Страница 6: ...ting time being set the machine will start to count down The machine will stop working after the countdown is finished If you need to cancel the countdown please press the button until the time displa...

Страница 7: ...The two arches at both sides of the operation panel are not handles and cannot be pulled The handles are at both sides of the purifier body 12 Do not place this machine up side down because there is...

Страница 8: ...e machine 2 Cellular Activated Carbon cold catalyst filter approximately once every two months Clean the dust from the front of the filter with a vacuum cleaner Place the filter in a ventilated area t...

Страница 9: ...rk properly First remove the particulate sensor cover use a dry cotton swab to wipe the lens Do not insert the cotton swab into any area other than the lens Be sure to unplug the power cord If you are...

Страница 10: ...mediately and contact the maintenance department Machine immediately goes to sleep mode Deactivate automatic mode Troubleshooting 1 Is the Power cord plugged in Plug in the power cord 2 Is the purifie...

Отзывы: