1)
Complete the first operation ONLY,
remove the can from the seamer, and
measure the first operation seam thickness
as shown.
First Operation Seam Thickness:
MK16s (and MK19s)
.074in - .078in
MK32
.104in - .112in
2)
Place the can back into the seamer
and run the second operation. Remove the
can and measure the final seam thickness
as shown.
Second Operation Seam Thickness:
MK16s (and MK19s)
.043in - .046in
MK32
.064in - .068in
3)
Using a tear-down tool, cut the top of
the can off.